{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T19:41:36Z","timestamp":1794598896905,"version":"4.9.1"},"reference-count":44,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2023,5,1]],"date-time":"2023-05-01T00:00:00Z","timestamp":1682899200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,5,1]],"date-time":"2023-05-01T00:00:00Z","timestamp":1682899200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,4,27]],"date-time":"2024-04-27T00:00:00Z","timestamp":1714176000000},"content-version":"am","delay-in-days":362,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Dental Materials"],"published-print":{"date-parts":[[2023,5]]},"DOI":"10.1016\/j.dental.2023.04.004","type":"journal-article","created":{"date-parts":[[2023,4,10]],"date-time":"2023-04-10T15:27:40Z","timestamp":1681140460000},"page":"522-528","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":20,"title":["Transient thermal stresses developed during speed sintering of 3\u00a0mol% yttria-stabilized tetragonal zirconia polycrystals"],"prefix":"10.1016","volume":"39","author":[{"given":"Abdulaziz M.","family":"Alshahrani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9028-4550","authenticated-orcid":false,"given":"Chek Hai","family":"Lim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeongho","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6738-3769","authenticated-orcid":false,"given":"Yu","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.dental.2023.04.004_bib1","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.dental.2010.10.024","article-title":"From porcelain-fused-to-metal to zirconia: clinical and experimental considerations","volume":"27","author":"Zarone","year":"2011","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib2","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/j.dental.2015.02.011","article-title":"All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: single crowns (SCs)","volume":"31","author":"Sailer","year":"2015","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib3","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1016\/j.sdentj.2020.05.004","article-title":"All-ceramic restorations: a review of the literature","volume":"32","author":"Warreth","year":"2020","journal-title":"Saudi Dent J"},{"key":"10.1016\/j.dental.2023.04.004_bib4","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1038\/258703a0","article-title":"Ceramic steel?","volume":"258","author":"Garvie","year":"1975","journal-title":"Nature"},{"key":"10.1016\/j.dental.2023.04.004_bib5","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1177\/0022034517737483","article-title":"Novel zirconia materials in dentistry","volume":"97","author":"Zhang","year":"2018","journal-title":"J Dent Res"},{"key":"10.1016\/j.dental.2023.04.004_bib6","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.dental.2007.05.007","article-title":"State of the art of zirconia for dental applications","volume":"24","author":"Denry","year":"2008","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib7","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1177\/154405910708600207","article-title":"Fracture of porcelain-veneered structures in fatigue","volume":"86","author":"Kim","year":"2007","journal-title":"J Dent Res"},{"key":"10.1016\/j.dental.2023.04.004_bib8","doi-asserted-by":"crossref","first-page":"4978","DOI":"10.3390\/ma8084978","article-title":"Zirconia as a dental miomaterial","volume":"8","author":"Bona","year":"2015","journal-title":"Materials"},{"key":"10.1016\/j.dental.2023.04.004_bib9","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1111\/jerd.12566","article-title":"Materials in digital dentistry-A review","volume":"32","author":"Sulaiman","year":"2020","journal-title":"J Esthet Restor Dent"},{"key":"10.1016\/j.dental.2023.04.004_bib10","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1016\/j.dental.2014.08.375","article-title":"Making yttria-stabilized tetragonal zirconia translucent","volume":"30","author":"Zhang","year":"2014","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib11","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1016\/j.ceramint.2015.09.033","article-title":"Characterization of three commercial Y-TZP ceramics produced for their high-translucency, high-strength and high-surface area","volume":"42","author":"Tong","year":"2016","journal-title":"Ceram Int"},{"key":"10.1016\/j.dental.2023.04.004_bib12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0142-9612(98)00010-6","article-title":"Zirconia as a ceramic biomaterial","volume":"20","author":"Piconi","year":"1999","journal-title":"Biomater"},{"issue":"12","key":"10.1016\/j.dental.2023.04.004_bib13","doi-asserted-by":"crossref","first-page":"17095","DOI":"10.1016\/j.ceramint.2022.02.265","article-title":"Composition, processing, and properties of biphasic zirconia bioceramics: Relationship to competing strength and optical properties","volume":"48","author":"Lim","year":"2022","journal-title":"Ceram Int"},{"issue":"129","key":"10.1016\/j.dental.2023.04.004_bib14","article-title":"Effect of sintering and aging processes on the mechanical and optical properties of translucent zirconia","volume":"126","author":"Kilinc","year":"2021","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.04.004_bib15","doi-asserted-by":"crossref","first-page":"161","DOI":"10.4047\/jap.2013.5.2.161","article-title":"Effects of the sintering conditions of dental zirconia ceramics on the grain size and translucency","volume":"5","author":"Kim","year":"2013","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.dental.2023.04.004_bib16","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1111\/jerd.12492","article-title":"The influence of altering sintering protocols on the optical and mechanical properties of zirconia: A review","volume":"31","author":"Ahmed","year":"2019","journal-title":"J Esthet Restor Dent"},{"key":"10.1016\/j.dental.2023.04.004_bib17","first-page":"171","article-title":"A computer program of master sintering curve model to accurately predict sintering results","volume":"2","author":"Teng","year":"2002","journal-title":"W PAC Earth Sci"},{"key":"10.1016\/j.dental.2023.04.004_bib18","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1016\/j.jmapro.2021.05.012","article-title":"Influence of sintering temperatures on material properties and corresponding milling machinability of zirconia ceramics","volume":"68","author":"Ji","year":"2021","journal-title":"J Manuf Process"},{"key":"10.1016\/j.dental.2023.04.004_bib19","doi-asserted-by":"crossref","first-page":"605","DOI":"10.4012\/dmj.2015-054","article-title":"The effect of staining and vacuum sintering on optical and mechanical properties of partially and fully stabilized monolithic zirconia","volume":"34","author":"Sulaiman","year":"2015","journal-title":"Dent Mater J"},{"key":"10.1016\/j.dental.2023.04.004_bib20","doi-asserted-by":"crossref","first-page":"4956","DOI":"10.1016\/j.jmrt.2019.06.043","article-title":"Zirconia in dental prosthetics: A literature review","volume":"8","author":"Grech","year":"2019","journal-title":"J Mater Res Technol"},{"key":"10.1016\/j.dental.2023.04.004_bib21","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.dental.2019.08.103","article-title":"Digital dentistry: The new state of the art - Is it disruptive or destructive?","volume":"36","author":"Rekow","year":"2020","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib22","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/j.prosdent.2019.02.005","article-title":"Impact of high-speed sintering on translucency, phase content, grain sizes, and flexural strength of 3Y-TZP and 4Y-TZP zirconia materials","volume":"122","author":"Jansen","year":"2019","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.04.004_bib23","first-page":"1105","article-title":"Super-speed sintered dental zirconia for chair-side one-visit application","volume":"6","author":"Li","year":"2018","journal-title":"Austin. J. Nutri. Food Sci"},{"key":"10.1016\/j.dental.2023.04.004_bib24","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1016\/j.dental.2020.04.026","article-title":"Mechanical properties, aging stability and translucency of speed-sintered zirconia for chairside restorations","volume":"36","author":"Cokic","year":"2020","journal-title":"Dent Mater"},{"issue":"16","key":"10.1016\/j.dental.2023.04.004_bib25","doi-asserted-by":"crossref","first-page":"4892","DOI":"10.3390\/jcm11164892","article-title":"Conventional, speed sintering and high-speed sintering of zirconia: a systematic review of the current status of applications in dentistry with a focus on precision, mechanical and optical parameters","volume":"11","author":"Al-Haj Husain","year":"2022","journal-title":"J Clin Med"},{"key":"10.1016\/j.dental.2023.04.004_bib26","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1111\/jerd.12524","article-title":"Strength and translucency of zirconia after high-speed sintering","volume":"32","author":"Lawson","year":"2020","journal-title":"J Esthet Restor Dent"},{"key":"10.1016\/j.dental.2023.04.004_bib27","doi-asserted-by":"crossref","first-page":"10999","DOI":"10.1016\/j.ceramint.2017.05.141","article-title":"Speed sintering translucent zirconia for chairside one-visit dental restorations: Optical, mechanical, and wear characteristics","volume":"43","author":"Kaizer","year":"2017","journal-title":"Ceram Int"},{"issue":"2","key":"10.1016\/j.dental.2023.04.004_bib28","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.dental.2021.12.028","article-title":"Influence of high-speed sintering protocols on translucency, mechanical properties, microstructure, crystallography, and low-temperature degradation of highly translucent zirconia","volume":"38","author":"Liu","year":"2022","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib29","doi-asserted-by":"crossref","first-page":"47","DOI":"10.11607\/ijp.6775","article-title":"Impact of high-speed sintering of three-unit 3Y-TZP and 4Y-TZP fixed dental prostheses on fracture load with and without artificial aging","volume":"34","author":"Mayinger","year":"2021","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.dental.2023.04.004_bib30","doi-asserted-by":"crossref","first-page":"9","DOI":"10.4012\/dmj.8.9","article-title":"Transient and residual stresses in dental porcelains as affected by cooling rates","volume":"8","author":"Asaoka","year":"1989","journal-title":"Dent Mater J"},{"key":"10.1016\/j.dental.2023.04.004_bib31","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.jmbbm.2018.03.020","article-title":"Viscoelastic finite element analysis of residual stresses in porcelain-veneered zirconia dental crowns","volume":"82","author":"Kim","year":"2018","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib32","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.dental.2014.02.020","article-title":"Influence of thermal gradients on stress state of veneered restorations","volume":"30","author":"Benetti","year":"2014","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib33","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1016\/j.dental.2007.08.008","article-title":"Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries","volume":"24","author":"DeHoff","year":"2008","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib34","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2019.103545","article-title":"Viscoelastic finite element evaluation of transient and residual stresses in dental crowns: Design parametric study","volume":"103","author":"Dhital","year":"2020","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib35","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1016\/j.dental.2021.08.019","article-title":"Residual stresses explaining clinical fractures of bilayer zirconia and lithium disilicate crowns: A VFEM study","volume":"37","author":"Rodrigues","year":"2021","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib36","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.1016\/j.dental.2011.08.001","article-title":"Thermal gradients and residual stresses in veneered Y-TZP frameworks","volume":"27","author":"Tholey","year":"2011","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.04.004_bib37","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1016\/j.dental.2013.08.212","article-title":"Analysis of thermal distributions in veneered zirconia and metal restorations during firing","volume":"29","author":"Benetti","year":"2013","journal-title":"Dent Mater"},{"issue":"6","key":"10.1016\/j.dental.2023.04.004_bib38","doi-asserted-by":"crossref","first-page":"C\u2010119","DOI":"10.1111\/j.1151-2916.1984.tb19715.x","article-title":"Calibration curve for quantitative analysis of the monoclinic-tetragonal ZrO2 system by X-ray diffraction","volume":"67","author":"Toraya","year":"1984","journal-title":"J Am Ceram Soc"},{"key":"10.1016\/j.dental.2023.04.004_bib39","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1111\/j.1151-2916.1972.tb11290.x","article-title":"Phase analysis in zirconia systems","volume":"55","author":"Garvie","year":"1972","journal-title":"J Am Ceram Soc"},{"key":"10.1016\/j.dental.2023.04.004_bib40","series-title":"Concepts and Applications of Finite Element Analysis","author":"Cook","year":"2007"},{"key":"10.1016\/j.dental.2023.04.004_bib41","doi-asserted-by":"crossref","first-page":"3567","DOI":"10.1016\/j.jeurceramsoc.2005.11.011","article-title":"Thermal conductivity of highly porous zirconia","volume":"26","author":"Nait-Ali","year":"2006","journal-title":"J Eur Ceram Soc"},{"issue":"10","key":"10.1016\/j.dental.2023.04.004_bib42","first-page":"E32","article-title":"Thermophysical properties characterization of zirconia prior to, during and after the sintering process","volume":"82","author":"Blumm","year":"2005","journal-title":"CFI Ceram Forum Int"},{"key":"10.1016\/j.dental.2023.04.004_bib43","doi-asserted-by":"crossref","first-page":"1668","DOI":"10.1016\/j.actbio.2008.12.016","article-title":"Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures","volume":"5","author":"Swain","year":"2009","journal-title":"Acta Biomater"},{"key":"10.1016\/j.dental.2023.04.004_bib44","doi-asserted-by":"crossref","first-page":"17376","DOI":"10.1016\/j.ceramint.2019.05.297","article-title":"High temperature mechanical properties of zirconia metastable t\u2032-Phase degraded yttria stabilized zirconia","volume":"45","author":"Wang","year":"2019","journal-title":"Ceram Int"}],"container-title":["Dental Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0109564123000933?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0109564123000933?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T22:53:27Z","timestamp":1758840807000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0109564123000933"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5]]},"references-count":44,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,5]]}},"alternative-id":["S0109564123000933"],"URL":"https:\/\/doi.org\/10.1016\/j.dental.2023.04.004","relation":{},"ISSN":["0109-5641"],"issn-type":[{"value":"0109-5641","type":"print"}],"subject":[],"published":{"date-parts":[[2023,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Transient thermal stresses developed during speed sintering of 3\u00a0mol% yttria-stabilized tetragonal zirconia polycrystals","name":"articletitle","label":"Article Title"},{"value":"Dental Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.dental.2023.04.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}