{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T23:20:46Z","timestamp":1793661646640,"version":"4.5.1"},"reference-count":64,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Dental Materials"],"published-print":{"date-parts":[[2024,2]]},"DOI":"10.1016\/j.dental.2023.11.012","type":"journal-article","created":{"date-parts":[[2023,11,17]],"date-time":"2023-11-17T10:18:16Z","timestamp":1700216296000},"page":"227-235","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":18,"title":["Biomechanical behavior and Weibull survival of CAD-CAM endocrowns with different marginal designs: A 3D finite element analysis"],"prefix":"10.1016","volume":"40","author":[{"given":"Rewaa G.","family":"AboElhassan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David C.","family":"Watts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rasha A.","family":"Alamoush","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8528-5441","authenticated-orcid":false,"given":"Alaaeldin","family":"Elraggal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.dental.2023.11.012_bib1","first-page":"117","article-title":"Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature, Part II (Evaluation of fatigue behavior, interfaces, and in vivo studies)","volume":"39","author":"Dietschi","year":"2008","journal-title":"Quintessence Int"},{"key":"10.1016\/j.dental.2023.11.012_bib2","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/j.joen.2007.01.016","article-title":"Influence of the endodontic treatment on mechanical properties of root dentin","volume":"33","author":"Soares","year":"2007","journal-title":"J Endod"},{"key":"10.1016\/j.dental.2023.11.012_bib3","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/0022-3913(94)90438-3","article-title":"Biomechanical considerations in restoring endodontically treated teeth","volume":"71","author":"Assif","year":"1994","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib4","first-page":"156","article-title":"Crown and post-free adhesive restorations for endodontically treated posterior teeth: from direct composite to endocrowns","volume":"8","author":"Rocca","year":"2013","journal-title":"Eur J Esthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib5","first-page":"189","article-title":"Pascal Magne: \u201cIt should not be about aesthetics but tooth-conserving dentistry","volume":"213","author":"Magne","year":"2012","journal-title":"Interview Ruth Doherty Br Dent J"},{"key":"10.1016\/j.dental.2023.11.012_bib6","first-page":"83","article-title":"Fabrication of a metal-free ceramic restoration utilizing the monobloc technique","volume":"7","author":"Pissis","year":"1995","journal-title":"Pr Periodontics Aesthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib7","first-page":"255","article-title":"Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years--preliminary results","volume":"1","author":"Bindl","year":"1999","journal-title":"J Adhes Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib8","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.prosdent.2016.10.006","article-title":"Lithium silicate endocrown fabricated with a CAD-CAM system: A functional and esthetic protocol","volume":"118","author":"da Cunha","year":"2017","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib9","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1016\/j.joen.2009.06.020","article-title":"Estimation of the risk of failure for an endodontically treated maxillary premolar with MODP preparation and CAD\/CAM ceramic restorations","volume":"35","author":"Lin","year":"2009","journal-title":"J Endod"},{"key":"10.1016\/j.dental.2023.11.012_bib10","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1111\/j.1600-0722.2009.00704.x","article-title":"Finite element and Weibull analyses to estimate failure risks in the ceramic endocrown and classical crown for endodontically treated maxillary premolar","volume":"118","author":"Lin","year":"2010","journal-title":"Eur J Oral Sci"},{"key":"10.1016\/j.dental.2023.11.012_bib11","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2023.105691","article-title":"Biomechanical properties of different endocrown designs on endodontically treated teeth","volume":"140","author":"Huang","year":"2023","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib12","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1007\/s00784-017-2142-y","article-title":"Clinical evaluation of zirconia-based all-ceramic single crowns: an up to 12-year retrospective cohort study","volume":"22","author":"Miura","year":"2018","journal-title":"Clin Oral Invest"},{"key":"10.1016\/j.dental.2023.11.012_bib13","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.jpor.2014.11.006","article-title":"A 3-year follow-up of ceria-stabilized zirconia\/alumina nanocomposite (Ce-TZP\/A) frameworks for fixed dental prostheses","volume":"59","author":"Tanaka","year":"2015","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.dental.2023.11.012_bib14","doi-asserted-by":"crossref","DOI":"10.1016\/j.dental.2013.04.026","article-title":"Fractographic analyses of all-ceramic crowns: a study of 27 clinically fractured crowns","volume":"29","author":"\u00d8ilo","year":"2013","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib15","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1007\/s00784-011-0606-z","article-title":"Influence of the supporting die structures on the fracture strength of all-ceramic materials","volume":"16","author":"Yucel","year":"2012","journal-title":"Clin Oral Invest"},{"key":"10.1016\/j.dental.2023.11.012_bib16","first-page":"445","article-title":"The effect of preparation design on the marginal stress of resin-bonded metal-free crowns: a finite element study","volume":"21","author":"Shinya","year":"2008","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.dental.2023.11.012_bib17","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1067\/mpr.2002.128378","article-title":"Marginal accuracy and fracture strength of ceromer\/fiber-reinforced composite crowns: Effect of variations in preparation design","volume":"88","author":"Cho","year":"2002","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib18","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1016\/j.prosdent.2015.11.017","article-title":"Load at fracture of monolithic and bilayered zirconia crowns with and without a cervical zirconia collar","volume":"115","author":"\u00d8ilo","year":"2016","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib19","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/S0022-3913(10)60184-9","article-title":"Mechanical behavior of ceramic veneer in zirconia-based restorations: a 3- dimensional finite element analysis using microcomputed tomography data","volume":"105","author":"Rocha","year":"2011","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib20","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.jpor.2017.11.003","article-title":"Fracture resistance and failure modes of polymer infiltrated ceramic endocrown restorations with variations in margin design and occlusal thickness","volume":"62","author":"Taha","year":"2018","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.dental.2023.11.012_bib21","doi-asserted-by":"crossref","first-page":"2667","DOI":"10.1016\/S0142-9612(01)00407-0","article-title":"Finite element analysis of a glass fibre reinforced composite endodontic post","volume":"23","author":"Pegoretti","year":"2002","journal-title":"Biomaterials"},{"key":"10.1016\/j.dental.2023.11.012_bib22","doi-asserted-by":"crossref","first-page":"50","DOI":"10.4012\/dmj.19.50","article-title":"Influence of different elastic moduli of dowel and core on stress distribution in root","volume":"19","author":"Ukon","year":"2000","journal-title":"Dent Mater J"},{"key":"10.1016\/j.dental.2023.11.012_bib23","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1016\/j.dental.2021.02.020","article-title":"Influence of surface treatments and cyclic fatigue on subsurface defects and mechanical properties of zirconia frameworks","volume":"37","author":"Elraggal","year":"2021","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib24","doi-asserted-by":"crossref","DOI":"10.1186\/s12903-022-02431-8","article-title":"Effect of surface treatments on biaxial flexural strength, fatigue resistance, and fracture toughness of high versus low translucency zirconia","volume":"22","author":"Elraggal","year":"2022","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.dental.2023.11.012_bib25","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1097\/00004770-200209000-00001","article-title":"Evaluation of two post core systems using two different methods (fracture strength test and a finite elemental stress analysis)","volume":"28","author":"Eskita\u015fcio\u01e7lu","year":"2002","journal-title":"J Endod"},{"key":"10.1016\/j.dental.2023.11.012_bib26","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.prosdent.2005.07.003","article-title":"Finite element analysis of stresses in endodontically treated, dowel-restored teeth","volume":"94","author":"Asmussen","year":"2005","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib27","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/S0109-5641(00)00009-9","article-title":"The influence of luting cement on the probabilities of survival and modes of failure of cast full-coverage crowns","volume":"16","author":"Mitchell","year":"2000","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib28","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1016\/j.dental.2004.05.001","article-title":"Stress distributions in adhesively cemented ceramic and resin-composite Class II inlay restorations: a 3D-FEA study","volume":"20","author":"Ausiello","year":"2004","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib29","article-title":"Effect of different endodontic access preparations on the biomechanical behavior of lithium disilicate and resin nanoceramic onlay restorations: An in vitro and 3D finite element analysis study","author":"Lai","year":"2022","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib30","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1016\/j.dental.2014.05.018","article-title":"The fracture resistance of a CAD\/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses","volume":"30","author":"Chen","year":"2014","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib31","doi-asserted-by":"crossref","first-page":"19217","DOI":"10.1016\/j.ceramint.2018.07.146","article-title":"Mechanical properties of hybrid computer-aided design\/computer-aided manufacturing (CAD\/CAM) materials after aging treatments","volume":"44","author":"Jeong","year":"2018","journal-title":"Ceram Int"},{"key":"10.1016\/j.dental.2023.11.012_bib32","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1016\/j.dental.2017.12.005","article-title":"Fatigue resistance of all-ceramic fixed partial dentures - Fatigue tests and finite element analysis","volume":"34","author":"Heintze","year":"2018","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib33","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.1016\/j.dental.2019.07.017","article-title":"Adhesive class I restorations in sound molar teeth incorporating combined resin-composite and glass ionomer materials: CAD-FE modeling and analysis","volume":"35","author":"Ausiello","year":"2019","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib34","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1177\/00220345950740060301","article-title":"Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modeling","volume":"74","author":"Kelly","year":"1995","journal-title":"J Dent Res"},{"key":"10.1016\/j.dental.2023.11.012_bib35","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1016\/j.dental.2010.10.025","article-title":"Slow crack growth and reliability of dental ceramics","volume":"27","author":"Gonzaga","year":"2011","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib36","first-page":"73","article-title":"Finite element and Weibull analysis to estimate failure risk in resin-bonded retainers","volume":"8","author":"Sato","year":"1995","journal-title":"Int J Prosthodont"},{"key":"10.1016\/j.dental.2023.11.012_bib37","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1016\/j.dental.2005.11.034","article-title":"Evaluation of the biomechanical behavior of maxillary central incisors restored by means of endocrowns compared to a natural tooth: a 3D static linear finite elements analysis","volume":"22","author":"Zarone","year":"2006","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib38","first-page":"36","article-title":"Effects of mesiodistal inclination of implants on stress distribution in implant-supported fixed prostheses","volume":"21","author":"Ca\u011flar","year":"2006","journal-title":"Int J Oral Maxillofac Implants"},{"key":"10.1016\/j.dental.2023.11.012_bib39","doi-asserted-by":"crossref","first-page":"661","DOI":"10.4012\/dmj.28.661","article-title":"Effects of different ceramic and composite materials on stress distribution in inlay and onlay cavities: 3-D finite element analysis","volume":"28","author":"Yamanel","year":"2009","journal-title":"Dent Mater J"},{"key":"10.1016\/j.dental.2023.11.012_bib40","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.dental.2016.10.008","article-title":"Chairside CAD\/CAM materials. Part 2: Flexural strength testing","volume":"33","author":"Wendler","year":"2017","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib41","doi-asserted-by":"crossref","first-page":"1179","DOI":"10.1016\/j.joen.2018.04.008","article-title":"Effect of intracoronal depth of teeth restored with endocrowns on fracture resistance: in vitro and 3-dimensional finite element analysis","volume":"44","author":"Dartora","year":"2018","journal-title":"J Endod"},{"key":"10.1016\/j.dental.2023.11.012_bib42","first-page":"333","article-title":"Structural stability of posterior retainer design for resin-bonded prostheses: a 3D finite element study","volume":"103","author":"Lin","year":"2015","journal-title":"Odont"},{"key":"10.1016\/j.dental.2023.11.012_bib43","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1034\/j.1600-9657.2001.170406.x","article-title":"Fracture resistance of human incisors and premolars: morphological and patho-anatomical factors","volume":"17","author":"Schatz","year":"2001","journal-title":"Dent Trauma"},{"key":"10.1016\/j.dental.2023.11.012_bib44","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1046\/j.1365-2842.1998.00293.x","article-title":"The variability of bite force measurement between sessions, in different positions within the dental arch","volume":"25","author":"Tortopidis","year":"1998","journal-title":"J Oral Rehabil"},{"key":"10.1016\/j.dental.2023.11.012_bib45","first-page":"284","article-title":"Occlusal control of mandibular elevator muscles","volume":"100","author":"Bakke","year":"1992","journal-title":"Scand J Dent Res"},{"key":"10.1016\/j.dental.2023.11.012_bib46","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1016\/j.dental.2018.06.024","article-title":"CAD-FEA modeling and analysis of different full crown monolithic restorations","volume":"34","author":"Dal Piva","year":"2018","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib47","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/j.prosdent.2015.04.016","article-title":"Mechanical properties of resin-ceramic CAD\/CAM restorative materials","volume":"114","author":"Awada","year":"2015","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib48","doi-asserted-by":"crossref","first-page":"201","DOI":"10.2341\/13-143-L","article-title":"Fracture resistance and microleakage of endocrowns utilizing three CAD-CAM blocks","volume":"40","author":"El-Damanhoury","year":"2015","journal-title":"Oper Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib49","doi-asserted-by":"crossref","first-page":"e504","DOI":"10.1111\/jopr.12770","article-title":"Three-Dimensional Digital Evaluation of the Fit of Endocrowns Fabricated from Different CAD\/CAM Materials","volume":"28","author":"Zimmermann","year":"2019","journal-title":"J Prosthodont"},{"key":"10.1016\/j.dental.2023.11.012_bib50","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.joen.2011.09.024","article-title":"Ferrule effect: a literature review","volume":"38","author":"Juloski","year":"2012","journal-title":"J Endod"},{"key":"10.1016\/j.dental.2023.11.012_bib51","doi-asserted-by":"crossref","first-page":"e237","DOI":"10.1111\/jopr.12671","article-title":"Preparation ferrule design effect on endocrown failure resistance","volume":"28","author":"Einhorn","year":"2019","journal-title":"J Prosthodont"},{"key":"10.1016\/j.dental.2023.11.012_bib52","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/0022-3913(90)90070-S","article-title":"Ferrule design and fracture resistance of endodontically treated teeth","volume":"63","author":"Sorensen","year":"1990","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib53","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.jdent.2012.10.004","article-title":"Effect of ferrule and post placement on fracture resistance of endodontically treated teeth after fatigue loading","volume":"41","author":"Zicari","year":"2013","journal-title":"J Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib54","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1038\/sj.bdj.2010.580","article-title":"Rethinking ferrule--a new approach to an old dilemma","volume":"209","author":"Jotkowitz","year":"2010","journal-title":"Br Dent J"},{"key":"10.1016\/j.dental.2023.11.012_bib55","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1007\/s00784-008-0217-5","article-title":"The finite element analysis of the effect of ferrule height on stress distribution at post-and-core-restored all-ceramic anterior crowns","volume":"13","author":"Eraslan","year":"2009","journal-title":"Clin Oral Invest"},{"key":"10.1016\/j.dental.2023.11.012_bib56","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/S0022-3913(09)60159-1","article-title":"Load fatigue of teeth with different ferrule lengths, restored with fiber posts, composite resin cores, and all-ceramic crowns","volume":"102","author":"Ma","year":"2009","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib57","first-page":"275","article-title":"Recent advances in composite CAD\/CAM blocks","volume":"11","author":"Mainjot","year":"2016","journal-title":"Int J Esthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib58","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.prosdent.2015.02.024","article-title":"Comparison of mechanical properties of three machinable ceramics with an experimental fluorophlogopite glass ceramic","volume":"114","author":"Leung","year":"2015","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib59","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.dental.2005.04.019","article-title":"Dynamic visco-elastic properties of dental composite resins","volume":"22","author":"Mesquita","year":"2006","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib60","first-page":"225","article-title":"Clinical performance of CAD\/CAM-fabricated monolithic zirconia endocrowns on molars with extensive coronal loss of substance","volume":"21","author":"Zou","year":"2018","journal-title":"Int J Comput Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib61","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/S0022-3913(08)60029-3","article-title":"Three-dimensional finite element analysis of strength and adhesion of composite resin versus ceramic inlays in molars","volume":"99","author":"Dejak","year":"2008","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2023.11.012_bib62","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1016\/S0021-9290(01)00098-7","article-title":"3D-finite element analyses of cusp movements in a human upper premolar, restored with adhesive resin-based composites","volume":"34","author":"Ausiello","year":"2001","journal-title":"J Biomech"},{"key":"10.1016\/j.dental.2023.11.012_bib63","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1016\/j.dental.2021.02.020","article-title":"Influence of surface treatments and cyclic fatigue on subsurface defects and mechanical properties of zirconia frameworks","volume":"37","author":"Elraggal","year":"2021","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2023.11.012_bib64","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1016\/j.dental.2017.12.007","article-title":"Strength and fracture toughness of zirconia dental ceramics","volume":"34","author":"Turon-Vinas","year":"2018","journal-title":"Dent Mater"}],"container-title":["Dental Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0109564123004505?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0109564123004505?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,6,15]],"date-time":"2024-06-15T01:53:13Z","timestamp":1718416393000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0109564123004505"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2]]},"references-count":64,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["S0109564123004505"],"URL":"https:\/\/doi.org\/10.1016\/j.dental.2023.11.012","relation":{},"ISSN":["0109-5641"],"issn-type":[{"value":"0109-5641","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical behavior and Weibull survival of CAD-CAM endocrowns with different marginal designs: A 3D finite element analysis","name":"articletitle","label":"Article Title"},{"value":"Dental Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.dental.2023.11.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}