{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T12:23:42Z","timestamp":1793103822117,"version":"4.5.0"},"reference-count":61,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100003803","name":"University of Hong Kong","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003803","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002920","name":"Research Grants Council, University Grants Committee","doi-asserted-by":"publisher","award":["GRF 17126724"],"award-info":[{"award-number":["GRF 17126724"]}],"id":[{"id":"10.13039\/501100002920","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Dental Materials"],"published-print":{"date-parts":[[2025,11]]},"DOI":"10.1016\/j.dental.2025.08.005","type":"journal-article","created":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T19:54:59Z","timestamp":1754942099000},"page":"1430-1441","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["High-strength DLP-printed zirconia for ultra-thin dental veneers"],"prefix":"10.1016","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-1310-1246","authenticated-orcid":false,"given":"Wuyuan","family":"Zhao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinxing","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sadia","family":"Manzoor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7940-1410","authenticated-orcid":false,"given":"Hao","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiaming","family":"Bai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0698-7155","authenticated-orcid":false,"given":"James K.H.","family":"Tsoi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.dental.2025.08.005_bib1","doi-asserted-by":"crossref","first-page":"523","DOI":"10.4012\/dmj.2019-200","article-title":"An introduction of biological performance of zirconia with different surface characteristics: a review","volume":"39","author":"Han","year":"2020","journal-title":"Dent Mater J"},{"key":"10.1016\/j.dental.2025.08.005_bib2","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2024.104925","article-title":"3D-printed versus conventionally milled zirconia for dental clinical applications: trueness, precision, accuracy, biological and esthetic aspects","volume":"144","author":"Alghauli","year":"2024","journal-title":"J Dent"},{"key":"10.1016\/j.dental.2025.08.005_bib3","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1016\/j.dental.2024.02.026","article-title":"Recent advances in dental zirconia: 15 years of material and processing evolution","volume":"40","author":"Cesar","year":"2024","journal-title":"Dent Mater Publ Acad Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib4","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1007\/s00784-016-1872-6","article-title":"Antagonist wear of monolithic zirconia crowns after 2 years","volume":"21","author":"Lohbauer","year":"2017","journal-title":"Clin Oral Investig"},{"key":"10.1016\/j.dental.2025.08.005_bib5","doi-asserted-by":"crossref","DOI":"10.3390\/coatings14040473","article-title":"Effects of Nano-Diamond-Coated milling bits on cutting dental zirconia","volume":"14","author":"Ding","year":"2024","journal-title":"Coatings"},{"key":"10.1016\/j.dental.2025.08.005_bib6","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.ijadhadh.2015.06.009","article-title":"Effects of sandblasting distance and angles on resin cement bonding to zirconia and titanium","volume":"62","author":"Ho","year":"2015","journal-title":"Int J Adhes Adhes"},{"key":"10.1016\/j.dental.2025.08.005_bib7","doi-asserted-by":"crossref","DOI":"10.1016\/j.dental.2025.02.004","article-title":"The influence of ph on the adhesive performance of phosphoric ester monomers with zirconia","author":"Han","year":"2025","journal-title":"Dent Mater Publ Acad Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib8","doi-asserted-by":"crossref","first-page":"26540","DOI":"10.1016\/j.ceramint.2023.05.188","article-title":"A novel magnetic field assisted automatic batch polishing method for dental ceramic crowns","volume":"49","author":"Loh","year":"2023","journal-title":"Ceram Int"},{"key":"10.1016\/j.dental.2025.08.005_bib9","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/j.dental.2025.02.006","article-title":"Influence of surface treatment before glazing on wear and flexural strength of translucent zirconia","volume":"41","author":"Wenger","year":"2025","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib10","article-title":"On the environmental impacts of 3D printing technology","volume":"20","author":"Khosravani","year":"2020","journal-title":"Appl Mater Today"},{"key":"10.1016\/j.dental.2025.08.005_bib11","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1016\/j.dental.2024.05.005","article-title":"Effects of printing orientation and artificial ageing on martens hardness and indentation modulus of 3D printed restorative resin materials","volume":"40","author":"Mudhaffer","year":"2024","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib12","doi-asserted-by":"crossref","DOI":"10.1016\/j.bprint.2025.e00395","article-title":"Evolution of medical 3D printing, printable biomaterials, prosthetic and regenerative dental applications","author":"Alghauli","year":"2025","journal-title":"Bioprinting"},{"key":"10.1016\/j.dental.2025.08.005_bib13","doi-asserted-by":"crossref","first-page":"2413","DOI":"10.1007\/s12541-014-0608-2","article-title":"Development of mask-less projection slurry stereolithography for the fabrication of zirconia dental coping","volume":"15","author":"Jiang","year":"2014","journal-title":"Int J Precis Eng Manuf"},{"key":"10.1016\/j.dental.2025.08.005_bib14","doi-asserted-by":"crossref","first-page":"1498","DOI":"10.1080\/10426914.2014.984208","article-title":"Development of a three-dimensional slurry printing system using dynamic mask projection for fabricating zirconia dental implants","volume":"30","author":"Lee","year":"2015","journal-title":"Mater Manuf Process"},{"key":"10.1016\/j.dental.2025.08.005_bib15","doi-asserted-by":"crossref","first-page":"e97","DOI":"10.1016\/j.dental.2019.02.001","article-title":"Effect of the volume fraction of zirconia suspensions on the microstructure and physical properties of products produced by additive manufacturing","volume":"35","author":"Jang","year":"2019","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib16","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.prosdent.2016.11.004","article-title":"A comparative study of additive and subtractive manufacturing for dental restorations","volume":"118","author":"Bae","year":"2017","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2025.08.005_bib17","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/j.jmbbm.2017.08.018","article-title":"3D-printing zirconia implants; a dream or a reality? An in-vitro study evaluating the dimensional accuracy, surface topography and mechanical properties of printed zirconia implant and discs","volume":"75","author":"Osman","year":"2017","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib18","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1111\/ijac.13441","article-title":"Fabrication of zirconia all-ceramic crown via DLP-based stereolithography","volume":"17","author":"Li","year":"2020","journal-title":"Int J Appl Ceram Technol"},{"key":"10.1016\/j.dental.2025.08.005_bib19","doi-asserted-by":"crossref","first-page":"7447","DOI":"10.1007\/s10853-019-03432-9","article-title":"Preparation of alumina-toughened zirconia via 3D printing and liquid precursor infiltration: manipulation of the microstructure, the mechanical properties and the low temperature aging behavior","volume":"54","author":"Wu","year":"2019","journal-title":"J Mater Sci"},{"key":"10.1016\/j.dental.2025.08.005_bib20","doi-asserted-by":"crossref","first-page":"18814","DOI":"10.1016\/j.ceramint.2019.06.111","article-title":"Accurate printing of a zirconia molar crown bridge using three-part auxiliary supports and ceramic mask projection stereolithography","volume":"45","author":"Lian","year":"2019","journal-title":"Ceram Int"},{"key":"10.1016\/j.dental.2025.08.005_bib21","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1108\/RPJ-03-2018-0053","article-title":"A comparison of the marginal fit and mechanical properties of a zirconia dental crown using CAM and 3DSP","volume":"25","author":"Hsu","year":"2019","journal-title":"Rapid Prototyp J"},{"key":"10.1016\/j.dental.2025.08.005_bib22","article-title":"Vat polymerization-printed partially stabilized zirconia: mechanical properties, reliability and structural defects","volume":"36","author":"Marsico","year":"2020","journal-title":"Addit Manuf"},{"key":"10.1016\/j.dental.2025.08.005_bib23","doi-asserted-by":"crossref","first-page":"28211","DOI":"10.1016\/j.ceramint.2020.07.321","article-title":"Digital light processing of zirconia prostheses with high strength and translucency for dental applications","volume":"46","author":"Kim","year":"2020","journal-title":"Ceram Int"},{"key":"10.1016\/j.dental.2025.08.005_bib24","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1016\/j.jeurceramsoc.2019.10.058","article-title":"Flexural strength and weibull analysis of Y-TZP fabricated by stereolithographic additive manufacturing and subtractive manufacturing","volume":"40","author":"Lu","year":"2020","journal-title":"J Eur Ceram Soc"},{"key":"10.1016\/j.dental.2025.08.005_bib25","doi-asserted-by":"crossref","first-page":"13457","DOI":"10.1016\/j.ceramint.2021.01.204","article-title":"Designing alumina-zirconia composites by DLP-based stereolithography: microstructural tailoring and mechanical performances","volume":"47","author":"Coppola","year":"2021","journal-title":"Ceram Int"},{"key":"10.1016\/j.dental.2025.08.005_bib26","first-page":"1","article-title":"Determination of hardness and fracture toughness of Y-TZP manufactured by digital light processing through the indentation technique","volume":"2021","author":"Mei","year":"2021","journal-title":"Biomed Res Int"},{"key":"10.1016\/j.dental.2025.08.005_bib27","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1016\/j.ceramint.2020.08.221","article-title":"Investigation on 3D printing ZrO2 implant abutment and its fatigue performance simulation","volume":"47","author":"Zhao","year":"2021","journal-title":"Ceram Int"},{"key":"10.1016\/j.dental.2025.08.005_bib28","doi-asserted-by":"crossref","first-page":"2974","DOI":"10.1016\/j.jeurceramsoc.2022.01.024","article-title":"Digital light processing stereolithography of zirconia ceramics: slurry elaboration and orientation-reliant mechanical properties","volume":"42","author":"Coppola","year":"2022","journal-title":"J Eur Ceram Soc"},{"key":"10.1016\/j.dental.2025.08.005_bib29","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103886","article-title":"Lithography-based ceramic manufacturing (LCM) versus milled zirconia blocks under uniaxial compressive loading: an in vitro comparative study","volume":"116","author":"Gatto","year":"2022","journal-title":"J Dent"},{"key":"10.1016\/j.dental.2025.08.005_bib30","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.3390\/ma15041337","article-title":"Evaluation of physical properties of zirconia suspension with added silane coupling agent for additive manufacturing processes","volume":"15","author":"Jang","year":"2022","journal-title":"Materials"},{"key":"10.1016\/j.dental.2025.08.005_bib31","doi-asserted-by":"crossref","DOI":"10.1016\/j.jdent.2021.103792","article-title":"Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: an in vitro study","volume":"113","author":"Lerner","year":"2021","journal-title":"J Dent"},{"key":"10.1016\/j.dental.2025.08.005_bib32","doi-asserted-by":"crossref","first-page":"600","DOI":"10.2186\/jpr.JPR_D_21_00240","article-title":"Physical and biological implications of accelerated aging on stereolithographic additive-manufactured zirconia for dental implant abutment","volume":"66","author":"Tan","year":"2021","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.dental.2025.08.005_bib33","doi-asserted-by":"crossref","first-page":"17852","DOI":"10.1016\/j.ceramint.2022.03.057","article-title":"Crown fit and dimensional accuracy of zirconia fixed crowns based on the digital light processing technology","volume":"48","author":"Meng","year":"2022","journal-title":"Ceram Int"},{"key":"10.1016\/j.dental.2025.08.005_bib34","doi-asserted-by":"crossref","first-page":"16572","DOI":"10.1016\/j.ceramint.2020.03.228","article-title":"Schwickerath adhesion tests of porcelain veneer and stereolithographic additive-manufactured zirconia","volume":"46","author":"Lu","year":"2020","journal-title":"Ceram Int"},{"key":"10.1016\/j.dental.2025.08.005_bib35","first-page":"207","article-title":"Minimally invasive treatment options in fixed prosthodontics","volume":"47","author":"Edelhoff","year":"2016","journal-title":"Quintessence Int"},{"key":"10.1016\/j.dental.2025.08.005_bib36","doi-asserted-by":"crossref","first-page":"79","DOI":"10.4047\/jap.2018.10.2.79","article-title":"In-vitro performance and fracture strength of thin monolithic zirconia crowns","volume":"10","author":"Weigl","year":"2018","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.dental.2025.08.005_bib37","doi-asserted-by":"crossref","first-page":"269","DOI":"10.4047\/jap.2021.13.5.269","article-title":"Monolithic zirconia crowns: effect of thickness reduction on fatigue behavior and failure load","volume":"13","author":"Prott","year":"2021","journal-title":"J Adv Prosthodont"},{"key":"10.1016\/j.dental.2025.08.005_bib38","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1016\/j.jmrt.2021.05.005","article-title":"Zirconia responses to edge chipping damage induced in conventional and ultrasonic vibration-assisted diamond machining","volume":"13","author":"Juri","year":"2021","journal-title":"J Mater Res Technol"},{"key":"10.1016\/j.dental.2025.08.005_bib39","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1016\/j.dental.2011.04.003","article-title":"Effect of the microstructure on the lifetime of dental ceramics","volume":"27","author":"Borba","year":"2011","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib40","article-title":"A comprehensive study of dense zirconia components fabricated by additive manufacturing","volume":"43","author":"Sun","year":"2021","journal-title":"Addit Manuf"},{"key":"10.1016\/j.dental.2025.08.005_bib41","doi-asserted-by":"crossref","first-page":"3376","DOI":"10.3390\/ma14123376","article-title":"Influence of the printing angle and load direction on flexure strength in 3D printed materials for provisional dental restorations","volume":"14","author":"Derban","year":"2021","journal-title":"Materials"},{"key":"10.1016\/j.dental.2025.08.005_bib42","doi-asserted-by":"crossref","first-page":"28837","DOI":"10.1016\/j.ceramint.2021.07.044","article-title":"Dental zirconia fabricated by stereolithography: accuracy, translucency and mechanical properties in different build orientations","volume":"47","author":"Xiang","year":"2021","journal-title":"Ceram Int"},{"key":"10.1016\/j.dental.2025.08.005_bib43","doi-asserted-by":"crossref","first-page":"4861","DOI":"10.1016\/j.actbio.2014.07.028","article-title":"Adhesion determination of dental porcelain to zirconia using the schwickerath test: strength vs. Fracture energy approach","volume":"10","author":"Kosyfaki","year":"2014","journal-title":"Acta Biomater"},{"key":"10.1016\/j.dental.2025.08.005_bib44","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1016\/j.dental.2014.03.005","article-title":"Influence of sintering conditions on low-temperature degradation of dental zirconia","volume":"30","author":"Inokoshi","year":"2014","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib45","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.jpor.2013.09.001","article-title":"Current status of zirconia restoration","volume":"57","author":"Miyazaki","year":"2013","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.dental.2025.08.005_bib46","doi-asserted-by":"crossref","DOI":"10.2186\/jpr.JPR_D_24_00092","article-title":"Influence of 3D printing orientations on physico-mechanical properties and accuracy of additively manufactured dental ceramics","author":"Alghauli","year":"2025","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.dental.2025.08.005_bib47","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.3390\/ma13051049","article-title":"Glass\u2013ceramics in dentistry: a review","volume":"13","author":"Fu","year":"2020","journal-title":"Materials"},{"key":"10.1016\/j.dental.2025.08.005_bib48","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1080\/00016350701459753","article-title":"Effect of operating air pressure on tribochemical silica-coating","volume":"65","author":"Heikkinen","year":"2007","journal-title":"Acta Odontol Scand"},{"key":"10.1016\/j.dental.2025.08.005_bib49","doi-asserted-by":"crossref","first-page":"354","DOI":"10.3109\/00016357.2010.514720","article-title":"The effect of laser treatment on bonding between zirconia ceramic surface and resin cement","volume":"68","author":"Ural","year":"2010","journal-title":"Acta Odontol Scand"},{"key":"10.1016\/j.dental.2025.08.005_bib50","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/S0022-3913(00)70036-9","article-title":"Color and translucency of in vivo natural central incisors","volume":"83","author":"Hasegawa","year":"2000","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.dental.2025.08.005_bib51","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.dental.2014.11.012","article-title":"M. Optical behavior of dental zirconia and dentin analyzed by Kubelka\u2013Munk theory","volume":"31","author":"Pecho","year":"2015","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib52","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1016\/j.dental.2014.08.375","article-title":"Making yttria-stabilized tetragonal zirconia translucent","volume":"30","author":"Zhang","year":"2014","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib53","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.jpor.2011.09.002","article-title":"Effect of thermal expansion mismatch on the Y-TZP\/veneer interfacial adhesion determined by strain energy release rate","volume":"56","author":"G\u00f6stemeyer","year":"2012","journal-title":"J Prosthodont Res"},{"key":"10.1016\/j.dental.2025.08.005_bib54","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1016\/j.jmbbm.2016.03.015","article-title":"Shear bond strength of veneering porcelain to zirconia: effect of surface treatment by CNC-milling and composite layer deposition on zirconia","volume":"60","author":"Santos","year":"2016","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib55","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1111\/jopr.12176","article-title":"Evaluation of experimental coating to improve the zirconia-veneering ceramic bond strength","volume":"23","author":"Matani","year":"2014","journal-title":"J Prosthodont"},{"key":"10.1016\/j.dental.2025.08.005_bib56","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1016\/j.dental.2017.06.007","article-title":"Comparison of three and four point bending evaluation of two adhesive bonding systems for glass-ceramic zirconia bi-layered ceramics","volume":"33","author":"Gee","year":"2017","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib57","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1016\/j.dental.2018.05.004","article-title":"Promoting porcelain\u2013zirconia bonding using different atmospheric pressure gas plasmas","volume":"34","author":"Liu","year":"2018","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib58","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.ijadhadh.2016.03.019","article-title":"Effect of various surface treatments on the interfacial adhesion between zirconia cores and porcelain veneers","volume":"69","author":"Yoon","year":"2016","journal-title":"Int J Adhes Adhes"},{"key":"10.1016\/j.dental.2025.08.005_bib59","doi-asserted-by":"crossref","first-page":"e8","DOI":"10.1016\/j.dental.2017.11.004","article-title":"Using glass-graded zirconia to increase delamination growth resistance in porcelain\/zirconia dental structures","volume":"34","author":"Chai","year":"2018","journal-title":"Dent Mater"},{"key":"10.1016\/j.dental.2025.08.005_bib60","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1111\/j.1151-2916.1986.tb07415.x","article-title":"Degradation during aging of transformation-toughened ZrO2-Y2O3 materials at 250\u00b0 c","volume":"69","author":"Lange","year":"1986","journal-title":"J Am Ceram Soc"},{"key":"10.1016\/j.dental.2025.08.005_bib61","doi-asserted-by":"crossref","first-page":"26935","DOI":"10.1016\/j.ceramint.2021.06.105","article-title":"Theoretical modeling based on stress wave propagation and experimental verification of residual stress in stereolithography printed ZrO2 ceramic suspensions","volume":"47","author":"Zhao","year":"2021","journal-title":"Ceram Int"}],"container-title":["Dental Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0109564125007341?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0109564125007341?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T16:07:46Z","timestamp":1777478866000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0109564125007341"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11]]},"references-count":61,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["S0109564125007341"],"URL":"https:\/\/doi.org\/10.1016\/j.dental.2025.08.005","relation":{},"ISSN":["0109-5641"],"issn-type":[{"value":"0109-5641","type":"print"}],"subject":[],"published":{"date-parts":[[2025,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"High-strength DLP-printed zirconia for ultra-thin dental veneers","name":"articletitle","label":"Article Title"},{"value":"Dental Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.dental.2025.08.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Academy of Dental Materials. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}