{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T19:58:44Z","timestamp":1722887924980},"reference-count":17,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2009,11,1]],"date-time":"2009-11-01T00:00:00Z","timestamp":1257033600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diabetes Research and Clinical Practice"],"published-print":{"date-parts":[[2009,11]]},"DOI":"10.1016\/j.diabres.2009.06.025","type":"journal-article","created":{"date-parts":[[2009,7,30]],"date-time":"2009-07-30T14:46:14Z","timestamp":1248965174000},"page":"e31-e33","source":"Crossref","is-referenced-by-count":4,"title":["Effect of delay on measurement of blood glucose levels in young subjects with type 1 diabetes"],"prefix":"10.1016","volume":"86","author":[{"given":"Daniela","family":"Elleri","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo L.","family":"Acerini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janet M.","family":"Allen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anne-Mette F.","family":"Larsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Malgorzata E.","family":"Wilinska","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David B.","family":"Dunger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roman","family":"Hovorka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.diabres.2009.06.025_bib1","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1089\/dia.2007.0216","article-title":"How to assess and compare the accuracy of continuous glucose monitors?","volume":"10","author":"Wentholt","year":"2008","journal-title":"Diabetes Technol. Ther."},{"issue":"12","key":"10.1016\/j.diabres.2009.06.025_bib2","doi-asserted-by":"crossref","first-page":"2040","DOI":"10.1373\/clinchem.2007.094466","article-title":"Glucose: a simple molecule that is not simple to quantify","volume":"53","author":"Gambino","year":"2007","journal-title":"Clin. Chem."},{"issue":"9","key":"10.1016\/j.diabres.2009.06.025_bib3","doi-asserted-by":"crossref","first-page":"1569","DOI":"10.1373\/clinchem.2004.044867","article-title":"Measurement of circulating glucose concentrations: the time is now for consistency among methods and types of samples","volume":"51","author":"Steffes","year":"2005","journal-title":"Clin. Chem."},{"issue":"2","key":"10.1016\/j.diabres.2009.06.025_bib4","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1093\/clinchem\/35.2.315","article-title":"Effectiveness of sodium-fluoride as a preservative of glucose in blood","volume":"35","author":"Chan","year":"1989","journal-title":"Clin. Chem."},{"issue":"4","key":"10.1016\/j.diabres.2009.06.025_bib5","doi-asserted-by":"crossref","first-page":"750","DOI":"10.2337\/diacare.25.4.750","article-title":"Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus","volume":"25","author":"Sacks","year":"2002","journal-title":"Diabetes Care"},{"issue":"3","key":"10.1016\/j.diabres.2009.06.025_bib6","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1080\/003655101300133612","article-title":"Optimization of preanalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus","volume":"61","author":"Stahl","year":"2001","journal-title":"Scand. J. Clin. Lab. Invest."},{"issue":"7","key":"10.1016\/j.diabres.2009.06.025_bib7","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1515\/CCLM.2003.133","article-title":"Conveying the importance of the preanalytical phase","volume":"41","author":"Young","year":"2003","journal-title":"Clin. Chem. Lab. Med."},{"issue":"3","key":"10.1016\/j.diabres.2009.06.025_bib8","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1111\/j.1479-828X.1997.tb02410.x","article-title":"Lag times between blood sampling, spinning and plasma glucose estimation","volume":"37","author":"McIntyre","year":"1997","journal-title":"Aust. N. Z. J. Obstet. Gynaecol."},{"issue":"5","key":"10.1016\/j.diabres.2009.06.025_bib9","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1373\/clinchem.2007.102160","article-title":"Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis","volume":"54","author":"Mikesh","year":"2008","journal-title":"Clin. Chem."},{"issue":"12","key":"10.1016\/j.diabres.2009.06.025_bib10","doi-asserted-by":"crossref","first-page":"2031","DOI":"10.1093\/clinchem\/22.12.2031","article-title":"Stabilization of blood-glucose by cooling with ice\u2014effective procedure for preservation of samples from adults and newborns","volume":"22","author":"Lin","year":"1976","journal-title":"Clin. Chem."},{"issue":"2","key":"10.1016\/j.diabres.2009.06.025_bib11","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1191\/096228099673819272","article-title":"Measuring agreement in method comparison studies","volume":"8","author":"Bland","year":"1999","journal-title":"Stat. Methods Med. Res."},{"issue":"11","key":"10.1016\/j.diabres.2009.06.025_bib12","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/j.cub.2006.04.026","article-title":"Circadian orchestration of the hepatic proteome","volume":"16","author":"Reddy","year":"2006","journal-title":"Curr. Biol."},{"key":"10.1016\/j.diabres.2009.06.025_bib13","first-page":"A91","article-title":"Assessment of RBC lifespan and in vivo HbA1c synthesis rate in human subjects","volume":"55","author":"Cohen","year":"2006","journal-title":"Diabetes"},{"issue":"9","key":"10.1016\/j.diabres.2009.06.025_bib14","doi-asserted-by":"crossref","first-page":"2445","DOI":"10.2337\/db07-1820","article-title":"Evidence for interindividual heterogeneity in the glucose gradient across the human red blood cell membrane and its relationship to hemoglobin glycation","volume":"57","author":"Khera","year":"2008","journal-title":"Diabetes"},{"issue":"5","key":"10.1016\/j.diabres.2009.06.025_bib15","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1111\/j.1651-2227.1997.tb08916.x","article-title":"Diagnosis of hypoglycaemia: effects of blood sample handling and evaluation of a glucose photometer in the low glucose range","volume":"86","author":"Elimam","year":"1997","journal-title":"Acta Paediatr."},{"issue":"4","key":"10.1016\/j.diabres.2009.06.025_bib16","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.siny.2005.04.002","article-title":"The investigation and management of neonatal hypoglycaemia","volume":"10","author":"Deshpande","year":"2005","journal-title":"Semin. Fetal Neonatal Med."},{"issue":"8","key":"10.1016\/j.diabres.2009.06.025_bib17","doi-asserted-by":"crossref","first-page":"1922","DOI":"10.2337\/diacare.27.8.1922","article-title":"Evaluating the accuracy of continuous glucose-monitoring sensors","volume":"27","author":"Kovatchev","year":"2004","journal-title":"Diabetes Care"}],"container-title":["Diabetes Research and Clinical Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0168822709002964?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0168822709002964?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,5,21]],"date-time":"2020-05-21T03:09:19Z","timestamp":1590030559000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0168822709002964"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,11]]},"references-count":17,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2009,11]]}},"alternative-id":["S0168822709002964"],"URL":"https:\/\/doi.org\/10.1016\/j.diabres.2009.06.025","relation":{},"ISSN":["0168-8227"],"issn-type":[{"value":"0168-8227","type":"print"}],"subject":[],"published":{"date-parts":[[2009,11]]}}}