{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T04:29:56Z","timestamp":1775276996418,"version":"3.50.1"},"reference-count":39,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,9,1]],"date-time":"2019-09-01T00:00:00Z","timestamp":1567296000000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","em-consulte.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Diagnostic and Interventional Imaging"],"published-print":{"date-parts":[[2018,9]]},"DOI":"10.1016\/j.diii.2018.04.006","type":"journal-article","created":{"date-parts":[[2018,5,9]],"date-time":"2018-05-09T22:02:03Z","timestamp":1525903323000},"page":"561-568","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"title":["Lower extremity CT angiography at 80 kVp using iterative model reconstruction"],"prefix":"10.1016","volume":"99","author":[{"given":"B.","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Z.","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Z.","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.diii.2018.04.006_bib0200","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1148\/radiol.11103564","article-title":"Peripheral arterial occlusive disease: diagnostic performance and effect on therapeutic management of 64-section CT angiography","volume":"261","author":"Napoli","year":"2011","journal-title":"Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0205","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1097\/RLI.0b013e31819b70ba","article-title":"The value of dual-energy bone removal in maximum intensity projections of lower extremity computed tomography angiography","volume":"44","author":"Sommer","year":"2009","journal-title":"Invest Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0210","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/S0140-6736(12)60815-0","article-title":"Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study","volume":"380","author":"Pearce","year":"2012","journal-title":"Lancet"},{"key":"10.1016\/j.diii.2018.04.006_bib0215","doi-asserted-by":"crossref","first-page":"2758","DOI":"10.1007\/s00330-010-1841-4","article-title":"Comparison of standard-and low-tube voltage MDCT angiography in patients with peripheral arterial disease","volume":"20","author":"Utsunomiya","year":"2012","journal-title":"Eur Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0220","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1177\/0284185114535391","article-title":"Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography","volume":"56","author":"Qi","year":"2015","journal-title":"Acta Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0225","doi-asserted-by":"crossref","first-page":"e99112","DOI":"10.1371\/journal.pone.0099112","article-title":"Image quality and radiation dose of lower extremity CT angiography using 70 kVp, high pitch acquisition and sinogram-affirmed iterative reconstruction","volume":"9","author":"Qi","year":"2014","journal-title":"PLoS One"},{"key":"10.1016\/j.diii.2018.04.006_bib0230","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1007\/s00330-014-3533-y","article-title":"Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography","volume":"25","author":"Chen","year":"2015","journal-title":"Eur Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0235","doi-asserted-by":"crossref","first-page":"47","DOI":"10.2214\/AJR.09.2592","article-title":"Dual-energy and low-kVp CT in the abdomen","volume":"193","author":"Yeh","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.diii.2018.04.006_bib0240","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1148\/radiol.2373041655","article-title":"Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise","volume":"237","author":"Nakayama","year":"2005","journal-title":"Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0245","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1177\/0284185114568909","article-title":"Image quality evaluation of iterative model reconstruction on low tube voltage (80 kVp) coronary CT angiography in an animal study","volume":"57","author":"Hu","year":"2016","journal-title":"Acta Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0250","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1007\/s10554-011-9832-3","article-title":"Iterative reconstruction for coronary CT angiography: finding its way","volume":"28","author":"Leipsic","year":"2012","journal-title":"Int J Cardiovasc Imaging"},{"key":"10.1016\/j.diii.2018.04.006_bib0255","doi-asserted-by":"crossref","first-page":"20150068","DOI":"10.1259\/bjr.20150068","article-title":"Dose reduction with iterative reconstruction for coronary CT angiography: a systematic review and meta-analysis","volume":"89","author":"Den Harder","year":"2016","journal-title":"Br J Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0260","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1016\/j.diii.2016.06.009","article-title":"Ultra-low-dose chest CT with iterative reconstruction does not alter anatomical image quality","volume":"97","author":"Macri","year":"2016","journal-title":"Diagn Interv Imaging"},{"key":"10.1016\/j.diii.2018.04.006_bib0265","doi-asserted-by":"crossref","first-page":"218","DOI":"10.3174\/ajnr.A2749","article-title":"Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection","volume":"33","author":"Korn","year":"2012","journal-title":"Am J Neuroradiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0270","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.diii.2015.02.007","article-title":"Dose reduction with iterative reconstruction: optimization of CT protocols in clinical practice","volume":"96","author":"Greffier","year":"2015","journal-title":"Diagn Interv Imaging"},{"key":"10.1016\/j.diii.2018.04.006_bib0275","doi-asserted-by":"crossref","first-page":"2521","DOI":"10.1007\/s00330-011-2227-y","article-title":"Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential","volume":"21","author":"Winklehner","year":"2011","journal-title":"Eur Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0280","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.diii.2015.06.019","article-title":"Dose reduction with iterative reconstruction in multi-detector CT: what is the impact on deformation of circular structures in phantom study?","volume":"97","author":"Greffier","year":"2016","journal-title":"Diagn Interv Imaging"},{"key":"10.1016\/j.diii.2018.04.006_bib0285","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/j.diii.2017.09.006","article-title":"Diagnostic performance of a low dose triple rule-out CT angiography using SAFIRE in emergency department","volume":"98","author":"Si-Mohamed","year":"2017","journal-title":"Diagn Interv Imaging"},{"key":"10.1016\/j.diii.2018.04.006_bib0290","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1007\/s00330-011-2361-6","article-title":"Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT","volume":"22","author":"Utsunomiya","year":"2012","journal-title":"Eur Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0295","doi-asserted-by":"crossref","first-page":"3905","DOI":"10.1016\/j.ejrad.2012.06.022","article-title":"The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT","volume":"81","author":"Hou","year":"2012","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0300","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1097\/RCT.0000000000000365","volume":"40","author":"Zhou","year":"2016","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.diii.2018.04.006_bib0305","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1177\/0284185117716701","article-title":"Knowledge-based iterative model reconstruction in coronary computed tomography angiography: comparison with hybrid iterative reconstruction and filtered back projection","volume":"59","author":"Cha","year":"2018","journal-title":"Acta Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0310","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1097\/RCT.0000000000000455","article-title":"Comparison of knowledge-based iterative model reconstruction and hybrid reconstruction techniques for liver CT evaluation of hypervascular hepatocellular carcinoma","volume":"40","author":"Park","year":"2016","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.diii.2018.04.006_bib0315","doi-asserted-by":"crossref","first-page":"20150766","DOI":"10.1259\/bjr.20150766","article-title":"Feasibility study of low tube voltage (80 kVp) coronary CT angiography combined with contrast medium reduction using iterative model reconstruction (IMR) on standard BMI patients","volume":"89","author":"Zhang","year":"2016","journal-title":"Br J Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0320","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1177\/0284185117725780","article-title":"Image quality and radiation dose of CT venography with double dose reduction using model based iterative reconstruction: comparison with conventional CT venography using filtered back projection","volume":"59","author":"Jeong","year":"2018","journal-title":"Acta Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0325","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1097\/RTI.0000000000000122","article-title":"Detection of pulmonary embolism on computed tomography: improvement using a model-based iterative reconstruction algorithm compared with filtered back projection and iterative reconstruction algorithms","volume":"30","author":"Kligerman","year":"2015","journal-title":"J Thorac Imaging"},{"key":"10.1016\/j.diii.2018.04.006_bib0330","doi-asserted-by":"crossref","first-page":"e0162429","DOI":"10.1371\/journal.pone.0162429","article-title":"CT pulmonary angiography at reduced radiation exposure and contrast material volume using iterative model reconstruction and iDose4 technique in comparison to FBP","volume":"11","author":"Laqmani","year":"2016","journal-title":"PLoS One"},{"key":"10.1016\/j.diii.2018.04.006_bib0335","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.acra.2016.05.011","article-title":"CT angiography in patients with peripheral arterial disease: effect of small focal spot imaging and iterative model reconstruction on the image quality","volume":"23","author":"Oda","year":"2016","journal-title":"Acad Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0340","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1097\/RCT.0000000000000356","article-title":"Improved image quality and decreased radiation dose of lower extremity computed tomography angiography using low-tube-voltage and adaptive iterative reconstruction","volume":"40","author":"Pan","year":"2016","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.diii.2018.04.006_bib0345","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1097\/RCT.0000000000000440","article-title":"Low-contrast and low-radiation dose protocol in cardiac computed tomography: usefulness of low tube voltage and knowledge-based iterative model reconstruction algorithm","volume":"40","author":"Iyama","year":"2016","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.diii.2018.04.006_bib0350","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1097\/RLI.0000000000000284","article-title":"Patient comfort during contrast media injection in coronary computed tomographic angiography using varying contrast media concentrations and flow rates: results from the EICAR trial","volume":"51","author":"Kok","year":"2016","journal-title":"Invest Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0355","doi-asserted-by":"crossref","first-page":"825","DOI":"10.2214\/AJR.09.3739","article-title":"Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT","volume":"195","author":"Wienbeck","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.diii.2018.04.006_bib0360","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1148\/radiol.2481071484","article-title":"Iso-osmolality versus low-osmolality iodinated contrast medium at intravenous contrast-enhanced CT: effect on kidney function","volume":"248","author":"Nguyen","year":"2008","journal-title":"Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0365","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1007\/s10554-012-0153-y","article-title":"Low contrast- and low radiation dose protocol for cardiac CT of thin adults at 256-row CT: usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm","volume":"29","author":"Nakaura","year":"2013","journal-title":"Int J Cardiovasc Imaging"},{"key":"10.1016\/j.diii.2018.04.006_bib0370","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.2214\/AJR.11.7117","article-title":"A hybrid iterative reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography","volume":"198","author":"Oda","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.diii.2018.04.006_bib0375","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.jcct.2013.12.010","article-title":"Value of knowledge-based iterative model reconstruction in low-kV 256-slice coronary CT angiography","volume":"8","author":"Yuki","year":"2014","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"10.1016\/j.diii.2018.04.006_bib0380","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1097\/RLI.0b013e3182899104","article-title":"Assessment of a model-based, iterative reconstruction algorithm (MBIR) regarding image quality and dose reduction in liver computed tomography","volume":"48","author":"Chang","year":"2013","journal-title":"Invest Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0385","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.1007\/s00330-012-2765-y","article-title":"Iterative reconstruction techniques for computed tomography Part 1: technical principles","volume":"23","author":"Willemink","year":"2013","journal-title":"Eur Radiol"},{"key":"10.1016\/j.diii.2018.04.006_bib0390","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.ejmp.2011.12.004","article-title":"Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments \u2013 a phantom approach","volume":"29","author":"Mieville","year":"2013","journal-title":"Phys Med"}],"container-title":["Diagnostic and Interventional Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2211568418300950?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2211568418300950?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,9,1]],"date-time":"2019-09-01T02:19:02Z","timestamp":1567304342000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2211568418300950"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9]]},"references-count":39,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2018,9]]}},"alternative-id":["S2211568418300950"],"URL":"https:\/\/doi.org\/10.1016\/j.diii.2018.04.006","relation":{},"ISSN":["2211-5684"],"issn-type":[{"value":"2211-5684","type":"print"}],"subject":[],"published":{"date-parts":[[2018,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Lower extremity CT angiography at 80 kVp using iterative model reconstruction","name":"articletitle","label":"Article Title"},{"value":"Diagnostic and Interventional Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.diii.2018.04.006","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Soci\u00e9t\u00e9 fran\u00e7aise de radiologie. Published by Elsevier Masson SAS.","name":"copyright","label":"Copyright"}]}}