{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T07:13:33Z","timestamp":1775805213393,"version":"3.50.1"},"reference-count":19,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2019,12,18]],"date-time":"2019-12-18T00:00:00Z","timestamp":1576627200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2019,12,18]],"date-time":"2019-12-18T00:00:00Z","timestamp":1576627200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2019,12,18]],"date-time":"2019-12-18T00:00:00Z","timestamp":1576627200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,12,18]],"date-time":"2019-12-18T00:00:00Z","timestamp":1576627200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2019,9,16]],"date-time":"2019-09-16T00:00:00Z","timestamp":1568592000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroscopytechniques.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["arthrosc. tech."],"published-print":{"date-parts":[[2020,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:label\/>\n                    <jats:p>Although open transosseous repair was historically used as a gold\u2010standard surgical solution for rotator cuff tears, this procedure was largely replaced by anchor\u2010based techniques because of the advancement of arthroscopic surgery. However, the ability of anchor\u2010based repair to achieve similar biomechanical fixation remains uncertain. Despite the proposals of numerous methods over the last decade, there remains demand for a standard, reliable technique that integrates the biomechanical advantages of transosseous fixation within the realm of arthroscopy. We describe a technique for transosseous rotator cuff repair using the Omnicuff, a needle\u2010based transosseous suture\u2010passing device that minimizes the risk of failure of suture passage between the bone tunnels. With potential advantages of this design including automated\u2010assisted suture passage, improved bone\u2010tendon healing, and anchorless fixation, surgeons may be inclined to consider these biomechanical and cost\u2010saving benefits. Future studies are warranted to determine clinical outcomes of this technique and its suitability for tears of varying degrees and patterns.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique Video<\/jats:title>\n                    <jats:p>\n                      <jats:boxed-text content-type=\"video\" position=\"anchor\">\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" position=\"anchor\" xlink:href=\"urn:x-wiley:22126287:media:atn2bf00953:atn2bf00953-vimg-mmc1\">\n                          <jats:alt-text>video<\/jats:alt-text>\n                        <\/jats:graphic>\n                      <\/jats:boxed-text>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>See video under supplementary data.<\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.eats.2019.09.004","type":"journal-article","created":{"date-parts":[[2019,12,18]],"date-time":"2019-12-18T10:01:22Z","timestamp":1576663282000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"title":["Arthroscopic, Needle\u2010Based, Transosseous Rotator Cuff Repair"],"prefix":"10.1002","volume":"9","author":[{"given":"Ehud","family":"Atoun","sequence":"first","affiliation":[{"name":"Barzilai Medical Center Department of Orthopaedic Surgery Ben Gurion University Beer Sheva Israel"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liam T.","family":"Kane","sequence":"additional","affiliation":[{"name":"Rothman Orthopaedic Institute Department of Orthopaedic Surgery Thomas Jefferson University Hospitals Philadelphia PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph A.","family":"Abboud","sequence":"additional","affiliation":[{"name":"Rothman Orthopaedic Institute Department of Orthopaedic Surgery Thomas Jefferson University Hospitals Philadelphia PA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2019,12,18]]},"reference":[{"key":"e_1_2_2_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.csm.2012.07.001"},{"issue":"304","key":"e_1_2_2_3_1","first-page":"3","article-title":"Lesions of the musculotendinous cuff of the shoulder. The exposure and treatment of tears with retraction","author":"McLaughlin H.L.","year":"1944","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_2_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2004.11.006"},{"key":"e_1_2_2_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.02.018"},{"key":"e_1_2_2_6_1","article-title":"Biomechanical strength of rotator cuff repairs: A systematic review and Meta\u2010regression Analysis of cadaveric studies","author":"Shi B.Y.","year":"2018","journal-title":"Am J Sports Med"},{"key":"e_1_2_2_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.07.029"},{"key":"e_1_2_2_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2018.10.004"},{"key":"e_1_2_2_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jos.2018.05.011"},{"key":"e_1_2_2_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2016.06.010"},{"issue":"9","key":"e_1_2_2_11_1","doi-asserted-by":"crossref","DOI":"10.1177\/0363546517695789","article-title":"Advantages of arthroscopic rotator cuff repair with a transosseous suture technique: A prospective Randomized Controlled Trial","volume":"45","author":"Randelli P.","year":"2017","journal-title":"Am J Sports Med"},{"key":"e_1_2_2_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12306-013-0254-3"},{"key":"e_1_2_2_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-011-1725-4"},{"key":"e_1_2_2_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-013-3148-7"},{"key":"e_1_2_2_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2018.05.003"},{"key":"e_1_2_2_16_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546512459170"},{"key":"e_1_2_2_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546509350081"},{"key":"e_1_2_2_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546510397171"},{"key":"e_1_2_2_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1758-5740.2011.00141.x"},{"key":"e_1_2_2_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2017.10.023"}],"container-title":["Arthroscopy Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628719302002?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628719302002?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2019.09.004","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.eats.2019.09.004","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2019.09.004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T06:27:47Z","timestamp":1775802467000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.eats.2019.09.004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,18]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,1]]}},"alternative-id":["10.1016\/j.eats.2019.09.004"],"URL":"https:\/\/doi.org\/10.1016\/j.eats.2019.09.004","archive":["Portico"],"relation":{},"ISSN":["2212-6287","2212-6287"],"issn-type":[{"value":"2212-6287","type":"print"},{"value":"2212-6287","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,18]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Arthroscopic, Needle-Based, Transosseous Rotator Cuff Repair","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.eats.2019.09.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 by the Arthroscopy Association of North America. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}