{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T02:05:16Z","timestamp":1792634716078,"version":"4.5.0"},"reference-count":8,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2024,1,16]],"date-time":"2024-01-16T00:00:00Z","timestamp":1705363200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,1,16]],"date-time":"2024-01-16T00:00:00Z","timestamp":1705363200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2024,1,16]],"date-time":"2024-01-16T00:00:00Z","timestamp":1705363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,1,16]],"date-time":"2024-01-16T00:00:00Z","timestamp":1705363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,12,4]],"date-time":"2023-12-04T00:00:00Z","timestamp":1701648000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","arthroscopytechniques.org","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["arthrosc. tech."],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:label\/>\n                    <jats:p>The main method for arthroscopic repair of the subscapularis is repair with suture anchors. The surgeon generally establishes the anterior and anterolateral operation portals to complete anchor implantation and suture passing, respectively. The single\u2013operation portal technique has been developed recently. However, in the traditional single\u2013operation portal technique, the suture device and grasper are difficult to operate simultaneously. In addition, with the traditional rotator cuff suture device, it is easy to cause further iatrogenic injury to the rotator cuff because of its larger diameter. Therefore, we describe a modified single\u2013operation portal technique for suture passing percutaneously with a spinal needle taking into account the shortcomings of existing techniques. Our modified technique avoids the use of traditional suturing devices and effectively avoids further damage to the rotator cuff. The use of a single operation portal makes the operation more minimally invasive and simple and effectively avoids the problem of interference between the suture device and grasper in the same portal. The entire operational process does not require the use of costly consumables, resulting in increased cost\u2010effectiveness and a significantly reduced operating time. In conclusion, our modified technique achieves the use of a single operation portal to suture the subscapularis through spinal needle suture passing, which has good clinical value.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique Video<\/jats:title>\n                    <jats:p>\n                      <jats:boxed-text content-type=\"video\" position=\"anchor\">\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" position=\"anchor\" xlink:href=\"urn:x-wiley:22126287:media:atn2bf02635:atn2bf02635-vimg-mmc2\">\n                          <jats:alt-text>video<\/jats:alt-text>\n                        <\/jats:graphic>\n                      <\/jats:boxed-text>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>See video under supplementary data.<\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.eats.2023.102898","type":"journal-article","created":{"date-parts":[[2024,1,16]],"date-time":"2024-01-16T09:20:28Z","timestamp":1705396828000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"title":["Modified Single\u2013Working Portal Technique Using Percutaneous Spinal Needle Suture Passing in Arthroscopic Subscapularis Repair"],"prefix":"10.1002","volume":"13","author":[{"given":"Hong","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenbo","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunqing","family":"Meng","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuyan","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,1,16]]},"reference":[{"key":"e_1_2_3_2_1","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2002.30648"},{"key":"e_1_2_3_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.csm.2022.08.004"},{"key":"e_1_2_3_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2020.06.005"},{"key":"e_1_2_3_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2021.09.007"},{"key":"e_1_2_3_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/os.13284"},{"key":"e_1_2_3_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.asmr.2022.01.009"},{"key":"e_1_2_3_8_1","article-title":"Needle\u2010based arthroscopic transosseous rotator cuff repair: A short\u2010term outcomes analysis","volume":"13","author":"Atoun E.","year":"2021","journal-title":"Cureus"},{"key":"e_1_2_3_9_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-021-02449-8"}],"container-title":["Arthroscopy Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628723003596?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628723003596?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2023.102898","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.eats.2023.102898","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2023.102898","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T12:11:13Z","timestamp":1775995873000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.eats.2023.102898"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,16]]},"references-count":8,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,4]]}},"alternative-id":["10.1016\/j.eats.2023.102898"],"URL":"https:\/\/doi.org\/10.1016\/j.eats.2023.102898","archive":["Portico"],"relation":{},"ISSN":["2212-6287","2212-6287"],"issn-type":[{"value":"2212-6287","type":"print"},{"value":"2212-6287","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,16]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Modified Single\u2013Working Portal Technique Using Percutaneous Spinal Needle Suture Passing in Arthroscopic Subscapularis Repair","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.eats.2023.102898","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}],"article-number":"102898"}}