{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T12:53:31Z","timestamp":1775998411257,"version":"3.50.1"},"reference-count":20,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2024,5,25]],"date-time":"2024-05-25T00:00:00Z","timestamp":1716595200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2024,5,25]],"date-time":"2024-05-25T00:00:00Z","timestamp":1716595200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2024,5,25]],"date-time":"2024-05-25T00:00:00Z","timestamp":1716595200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,5,25]],"date-time":"2024-05-25T00:00:00Z","timestamp":1716595200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,4,25]],"date-time":"2024-04-25T00:00:00Z","timestamp":1714003200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","arthroscopytechniques.org","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["arthrosc. tech."],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:label\/>\n                    <jats:p>This technical note outlines a minimalist arthroscopic approach to anterior cruciate ligament avulsion fracture fixation using a bioabsorbable knotless suture anchor. This method represents a less invasive alternative to traditional techniques, catering specifically to fractures classified as Meyers and McKeever type II or III. The procedure is performed through standard anterolateral and anteromedial portals without the need for additional incisions or bone tunnel drilling, making it particularly suitable for children and adolescent patients with open physes. The technique involves the use of a suture hook to pass a double\u2010stranded suture through the anterior cruciate ligament, anchored eccentrically to the anterior tibial incline with a knotless suture anchor. This approach allows for anatomic reduction with adjustable tension and without the potential risk of iatrogenic osteochondral injury. Nonetheless, it should be acknowledged that prospective biomechanical studies and larger patient samples are necessary to validate this technique compared with existing fixation methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique Video<\/jats:title>\n                    <jats:p>\n                      <jats:boxed-text content-type=\"video\" position=\"anchor\">\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" position=\"anchor\" xlink:href=\"urn:x-wiley:22126287:media:atn2bf02792:atn2bf02792-vimg-mmc1\">\n                          <jats:alt-text>video<\/jats:alt-text>\n                        <\/jats:graphic>\n                      <\/jats:boxed-text>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>See video under supplementary data.<\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.eats.2024.103058","type":"journal-article","created":{"date-parts":[[2024,5,25]],"date-time":"2024-05-25T22:50:17Z","timestamp":1716677417000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Arthroscopic Anterior Cruciate Ligament Avulsion Fixation With a Knotless Suture Anchor: A Minimalistic Approach"],"prefix":"10.1002","volume":"13","author":[{"given":"Cheng","family":"Luo","sequence":"first","affiliation":[{"name":"Department of Osteoarthropathy and Sports Medicine The Affiliated Panyu Central Hospital of Guangzhou Medical University Guangzhou China"},{"name":"Rehabilitation Medicine Institute of Panyu District The Affiliated Panyu Central Hospital of Guangzhou Medical University Guangzhou China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yijun","family":"He","sequence":"additional","affiliation":[{"name":"Department of Osteoarthropathy and Sports Medicine The Affiliated Panyu Central Hospital of Guangzhou Medical University Guangzhou China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiongfeng","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Osteoarthropathy and Sports Medicine The Affiliated Panyu Central Hospital of Guangzhou Medical University Guangzhou China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2024,5,25]]},"reference":[{"key":"e_1_2_4_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jisako.2023.06.001"},{"key":"e_1_2_4_3_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197759080-00022"},{"key":"e_1_2_4_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2023.08.008"},{"key":"e_1_2_4_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2023.09.029"},{"key":"e_1_2_4_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2023.08.020"},{"key":"e_1_2_4_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2023.02.052"},{"key":"e_1_2_4_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2021.03.018"},{"key":"e_1_2_4_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2020.12.003"},{"key":"e_1_2_4_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.12.008"},{"key":"e_1_2_4_11_1","first-page":"13797","article-title":"Treatment of tibial eminence fractures with arthroscopic suture fixation technique: A retrospective study","volume":"8","author":"Yuan Y.","year":"2015","journal-title":"Int J Clin Exp Med"},{"key":"e_1_2_4_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2012.12.008"},{"key":"e_1_2_4_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2022.02.002"},{"key":"e_1_2_4_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/0020-1383(92)90013-I"},{"key":"e_1_2_4_15_1","first-page":"CD009679","article-title":"Surgical fixation methods for tibial plateau fractures","volume":"2015","author":"McNamara I.R.","year":"2015","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_2_4_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.06.019"},{"key":"e_1_2_4_17_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-022-03219-w"},{"key":"e_1_2_4_18_1","first-page":"681","article-title":"Biomechanical comparison of tibial eminence fracture fixation with high\u2010strength suture, EndoButton, and suture anchor","volume":"28","author":"Hapa O.","year":"2012","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"e_1_2_4_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-016-4339-z"},{"key":"e_1_2_4_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-007-0466-x"},{"key":"e_1_2_4_21_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0030-1247742"}],"container-title":["Arthroscopy Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628724001671?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628724001671?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2024.103058","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.eats.2024.103058","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2024.103058","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T12:34:44Z","timestamp":1775997284000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.eats.2024.103058"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,25]]},"references-count":20,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2024,9]]}},"alternative-id":["10.1016\/j.eats.2024.103058"],"URL":"https:\/\/doi.org\/10.1016\/j.eats.2024.103058","archive":["Portico"],"relation":{},"ISSN":["2212-6287","2212-6287"],"issn-type":[{"value":"2212-6287","type":"print"},{"value":"2212-6287","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,25]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Arthroscopic Anterior Cruciate Ligament Avulsion Fixation With a Knotless Suture Anchor: A Minimalistic Approach","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.eats.2024.103058","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}],"article-number":"103058"}}