{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T21:01:20Z","timestamp":1776286880802,"version":"3.50.1"},"reference-count":5,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2024,8,17]],"date-time":"2024-08-17T00:00:00Z","timestamp":1723852800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,8,17]],"date-time":"2024-08-17T00:00:00Z","timestamp":1723852800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2024,8,17]],"date-time":"2024-08-17T00:00:00Z","timestamp":1723852800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,8,17]],"date-time":"2024-08-17T00:00:00Z","timestamp":1723852800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,6,20]],"date-time":"2024-06-20T00:00:00Z","timestamp":1718841600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","arthroscopytechniques.org","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["arthrosc. tech."],"published-print":{"date-parts":[[2024,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:label\/>\n                    <jats:p>Tearing of the subscapularis tendon is a common shoulder injury that typically requires arthroscopic repair. The suture\u2010passing device is a standard tool for repairing the subscapularis tendon. However, it poses the risk of device breakage and may cause additional damage to the tendon. Additionally, a traditional suture hook technique using traction sutures necessitate repeated puncturing, which increases both the complexity of the procedure and the risk of tendon damage. In this Technical Note, we describe an improvement on the previously reported continuous suturing technique by introducing a percutaneous, sewing machine\u2013like continuous subscapularis tendon suture method through a single working portal. The key innovation in our technique is the use of a percutaneous spinal needle for suturing, along with the sewing machine\u2013like continuous suture approach. By eliminating the traditional suture\u2010passing devices and traction sutures, our method allows for clearer suture management; more flexible puncture site selection; and a faster, simpler suture process.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique Video<\/jats:title>\n                    <jats:p>\n                      <jats:boxed-text content-type=\"video\" position=\"anchor\">\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" position=\"anchor\" xlink:href=\"urn:x-wiley:22126287:media:atn2bf02628:atn2bf02628-vimg-mmc1\">\n                          <jats:alt-text>video<\/jats:alt-text>\n                        <\/jats:graphic>\n                      <\/jats:boxed-text>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>See video under supplementary data.<\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.eats.2024.103151","type":"journal-article","created":{"date-parts":[[2024,8,17]],"date-time":"2024-08-17T07:45:09Z","timestamp":1723880709000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Arthroscopic Repair of Subscapularis Tendon Using a Percutaneous Continuous Sewing Machine\u2013Like Suture Technique Through a Single Working Portal"],"prefix":"10.1002","volume":"13","author":[{"given":"Wenbo","family":"Yang","sequence":"first","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yizhong","family":"Peng","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chunqing","family":"Meng","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Union Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2024,8,17]]},"reference":[{"key":"e_1_2_3_2_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0042-1756167"},{"key":"e_1_2_3_3_1","doi-asserted-by":"publisher","DOI":"10.1055\/a-1387-8079"},{"key":"e_1_2_3_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2021.09.007"},{"key":"e_1_2_3_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jisako.2022.01.002"},{"key":"e_1_2_3_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2023.01.010"}],"container-title":["Arthroscopy Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628724002767?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628724002767?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2024.103151","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.eats.2024.103151","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2024.103151","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T12:48:57Z","timestamp":1775998137000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.eats.2024.103151"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,17]]},"references-count":5,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["10.1016\/j.eats.2024.103151"],"URL":"https:\/\/doi.org\/10.1016\/j.eats.2024.103151","archive":["Portico"],"relation":{},"ISSN":["2212-6287","2212-6287"],"issn-type":[{"value":"2212-6287","type":"print"},{"value":"2212-6287","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,17]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Arthroscopic Repair of Subscapularis Tendon Using a Percutaneous Continuous Sewing Machine\u2013Like Suture Technique Through a Single Working Portal","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.eats.2024.103151","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}],"article-number":"103151"}}