{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T18:09:24Z","timestamp":1778695764038,"version":"3.51.4"},"reference-count":23,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T00:00:00Z","timestamp":1736208000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T00:00:00Z","timestamp":1736208000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T00:00:00Z","timestamp":1736208000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T00:00:00Z","timestamp":1736208000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T00:00:00Z","timestamp":1734307200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroscopytechniques.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["arthrosc. tech."],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:label\/>\n                    <jats:p>Tendon transfers are preferred in patients with massive, irreparable posterosuperior rotator cuff tears without glenohumeral arthritis. Recently, a surge of lower trapezius transfer over latissimus dorsi transfer has been observed due to its biomechanical superiority. We present an arthroscopy\u2010assisted lower trapezius transfer technique using a reusable transosseous system and a peroneus longus autograft. The reusable repair system and autograft make this technique both accessible and affordable. With its potential to improve patient outcomes and reduce health care costs, this lower trapezius transfer technique is a valuable addition to shoulder surgery. By sharing our experience, we hope to facilitate wider adoption of this approach.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique Video<\/jats:title>\n                    <jats:p>\n                      <jats:boxed-text content-type=\"video\" position=\"anchor\">\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" position=\"anchor\" xlink:href=\"urn:x-wiley:22126287:media:atn2bf03422:atn2bf03422-vimg-mmc1\">\n                          <jats:alt-text>video<\/jats:alt-text>\n                        <\/jats:graphic>\n                      <\/jats:boxed-text>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>See video under supplementary data.<\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.eats.2024.103411","type":"journal-article","created":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T15:51:49Z","timestamp":1736265109000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Arthroscopy\u2010Assisted Transosseous Lower Trapezius Transfer With Peroneus Longus Autograft Using a Reusable Transosseous Repair System for Massive Irreparable Cuff Tears"],"prefix":"10.1002","volume":"14","author":[{"given":"Senthilvelan","family":"Rajagopalan","sequence":"first","affiliation":[{"name":"Shoulder and Upper Limb Unit MIOT International Hospital Chennai India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Girinivasan","family":"Chellamuthu","sequence":"additional","affiliation":[{"name":"Shoulder and Upper Limb Unit MIOT International Hospital Chennai India"},{"name":"Karpagam Academy of Higher Education Coimbatore India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robin G.","family":"Alex","sequence":"additional","affiliation":[{"name":"Shoulder and Upper Limb Unit MIOT International Hospital Chennai India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,1,7]]},"reference":[{"key":"e_1_2_4_2_1","doi-asserted-by":"publisher","DOI":"10.1530\/EOR-22-0015"},{"key":"e_1_2_4_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2012.01.026"},{"key":"e_1_2_4_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2016.04.025"},{"key":"e_1_2_4_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2023.07.049"},{"key":"e_1_2_4_6_1","doi-asserted-by":"publisher","DOI":"10.1177\/17585732221135181"},{"key":"e_1_2_4_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.xrrt.2022.05.007"},{"key":"e_1_2_4_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2016.01.003"},{"key":"e_1_2_4_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2021.12.047"},{"key":"e_1_2_4_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.asmr.2022.09.002"},{"key":"e_1_2_4_11_1","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOS-D-22-00057"},{"key":"e_1_2_4_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2013.08.005"},{"key":"e_1_2_4_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.03.032"},{"key":"e_1_2_4_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-011-1725-4"},{"key":"e_1_2_4_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-013-3148-7"},{"key":"e_1_2_4_16_1","first-page":"E415","article-title":"Arthroscopic transosseous and transosseous\u2010equivalent rotator cuff repair: An analysis of cost, operative time, and clinical outcomes","volume":"45","author":"Seidl A.J.","year":"2016","journal-title":"Am J Orthop"},{"key":"e_1_2_4_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546517695789"},{"key":"e_1_2_4_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2023.06.029"},{"key":"e_1_2_4_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2020.02.018"},{"key":"e_1_2_4_20_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465221092137"},{"key":"e_1_2_4_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jor.2020.08.007"},{"key":"e_1_2_4_22_1","doi-asserted-by":"publisher","DOI":"10.15537\/smj.2023.44.2.20220721"},{"key":"e_1_2_4_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-024-03984-w"},{"key":"e_1_2_4_24_1","doi-asserted-by":"publisher","DOI":"10.1155\/2023\/2018363"}],"container-title":["Arthroscopy Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628724005796?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628724005796?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2024.103411","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.eats.2024.103411","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2024.103411","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T12:42:06Z","timestamp":1775997726000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.eats.2024.103411"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,7]]},"references-count":23,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["10.1016\/j.eats.2024.103411"],"URL":"https:\/\/doi.org\/10.1016\/j.eats.2024.103411","archive":["Portico"],"relation":{},"ISSN":["2212-6287","2212-6287"],"issn-type":[{"value":"2212-6287","type":"print"},{"value":"2212-6287","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Arthroscopy-Assisted Transosseous Lower Trapezius Transfer With Peroneus Longus Autograft Using a Reusable Transosseous Repair System for Massive Irreparable Cuff Tears","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.eats.2024.103411","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}],"article-number":"103411"}}