{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T00:32:40Z","timestamp":1790382760593,"version":"4.1.0"},"reference-count":10,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,1,10]],"date-time":"2025-01-10T00:00:00Z","timestamp":1736467200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroscopytechniques.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["arthrosc. tech."],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:label\/>\n                    <jats:p>Osteotomy around the knee is a valid surgical option for patients with lower\u2010limb malalignment due to extra\u2010articular metaphyseal deformities as a cause of unicompartmental knee osteoarthritis. One of the most dreaded complications of this surgical procedure is the hinge fracture. One method that has been shown to prevent this complication is the use of a K\u2010wire on the opposite side of the osteotomy, across the hinge, with the addition of a positional screw to increase the stability of the fixation. In this technical note, we describe a simple and replicable technique for inserting a hinge\u2010protective wire and a cannulated positional screw.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique Video<\/jats:title>\n                    <jats:p>\n                      <jats:boxed-text content-type=\"video\" position=\"anchor\">\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" position=\"anchor\" xlink:href=\"urn:x-wiley:22126287:media:atn2bf03452:atn2bf03452-vimg-mmc1\">\n                          <jats:alt-text>video<\/jats:alt-text>\n                        <\/jats:graphic>\n                      <\/jats:boxed-text>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>See video under supplementary data.<\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.eats.2025.103448","type":"journal-article","created":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T07:19:55Z","timestamp":1738394395000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Percutaneous Hinge K\u2010Wire and Screw in Osteotomy Around the Knee: A Technical Note"],"prefix":"10.1002","volume":"14","author":[{"given":"T\u00e2nia Alegre","family":"Veigas","sequence":"first","affiliation":[{"name":"Hospital CUF Santar\u00e9m Santar\u00e9m Portugal"},{"name":"Unidade Local de Sa\u00fade Entre o Douro e Vouga Santa Maria da Feira Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guilherme","family":"de Paiva Marques","sequence":"additional","affiliation":[{"name":"Hospital CUF Santar\u00e9m Santar\u00e9m Portugal"},{"name":"Hospital Curry Cabral Unidade Local de Sa\u00fade de S\u00e3o Jos\u00e9 Lisboa Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gon\u00e7alo","family":"Martinho","sequence":"additional","affiliation":[{"name":"Hospital CUF Santar\u00e9m Santar\u00e9m Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jo\u00e3o","family":"Raposo","sequence":"additional","affiliation":[{"name":"Hospital CUF A\u00e7ores Lagoa Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jo\u00e3o","family":"Lobo","sequence":"additional","affiliation":[{"name":"Unidade Local de Sa\u00fade de S\u00e3o Jo\u00e3o Porto Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jo\u00e3o","family":"Campos","sequence":"additional","affiliation":[{"name":"Unidade Local de Sa\u00fade de Matosinhos Senhora da Hora Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Levi","family":"Reina Fernandes","sequence":"additional","affiliation":[{"name":"Hospital CUF Santar\u00e9m Santar\u00e9m Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,2,1]]},"reference":[{"key":"e_1_2_3_2_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-023-00708-7"},{"key":"e_1_2_3_3_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465221148496"},{"key":"e_1_2_3_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2023.09.010"},{"key":"e_1_2_3_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2023.07.054"},{"key":"e_1_2_3_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-019-05404-7"},{"key":"e_1_2_3_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-022-07286-8"},{"key":"e_1_2_3_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2020.02.015"},{"key":"e_1_2_3_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-022-04573-4"},{"key":"e_1_2_3_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/ksa.12273"},{"key":"e_1_2_3_11_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546519869325"}],"container-title":["Arthroscopy Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628725000179?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628725000179?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2025.103448","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.eats.2025.103448","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2025.103448","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T12:42:29Z","timestamp":1775997749000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.eats.2025.103448"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,1]]},"references-count":10,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["10.1016\/j.eats.2025.103448"],"URL":"https:\/\/doi.org\/10.1016\/j.eats.2025.103448","archive":["Portico"],"relation":{},"ISSN":["2212-6287","2212-6287"],"issn-type":[{"value":"2212-6287","type":"print"},{"value":"2212-6287","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Percutaneous Hinge K-Wire and Screw in Osteotomy Around the Knee: A Technical Note","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.eats.2025.103448","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}],"article-number":"103448"}}