{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T12:02:57Z","timestamp":1775736177070,"version":"3.50.1"},"reference-count":12,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T00:00:00Z","timestamp":1747699200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T00:00:00Z","timestamp":1747699200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T00:00:00Z","timestamp":1747699200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T00:00:00Z","timestamp":1747699200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,4,2]],"date-time":"2025-04-02T00:00:00Z","timestamp":1743552000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroscopytechniques.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["arthrosc. tech."],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:label\/>\n                    <jats:p>Although the arthroscopic Latarjet procedure has evolved as the most reliable bony sling procedure for shoulder instability with bone loss, the soft cancellous nature of the coracoid makes the FiberTape option for metal\u2010free fixation difficult because of cheese wiring and cutting into the coracoid when the tape is tensioned. Hence, long titanium screws or titanium buttons are used to fix the coracoid in all existing methods for the Latarjet procedure. Rigid and metal\u2010based methods can cause abrasion of the bony moving surfaces coated with cartilage and can cause wear to contact areas, especially when osteolysis occurs during remodeling of the coracoid bone. We describe an absorbable poly lactic acid 3\u2010dimensional printed coracoid protector (which we call the SJ Buckler) to protect the coracoid process resting on its anterior surface and prevent cut through, with laboratory\u2010verified strength to withstand greater than 120 N. This allows us to perform metal\u2010free fixation of the coracoid in the Latarjet procedure, which can be performed arthroscopically or open, where the coracoid tensioning can be done without fear of cut\u2010through. The poly lactic acid material is absorbable and will integrate to bone or disintegrate after the purpose of bony union to glenoid has been achieved.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique Video<\/jats:title>\n                    <jats:p>\n                      <jats:boxed-text content-type=\"video\" position=\"anchor\">\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" position=\"anchor\" xlink:href=\"urn:x-wiley:22126287:media:atn2bf04107:atn2bf04107-vimg-0001\">\n                          <jats:alt-text>video<\/jats:alt-text>\n                        <\/jats:graphic>\n                      <\/jats:boxed-text>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>See video under supplementary data.<\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.eats.2025.103560","type":"journal-article","created":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T15:48:25Z","timestamp":1747756105000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Metal\u2010Free Cerclage Method of Arthroscopic Latarjet Using a Printed Poly Lactic Acid Coracoid Protector to Prevent Coracoid Stress Riser While Tensioning"],"prefix":"10.1002","volume":"14","author":[{"given":"Sujit","family":"Jos","sequence":"first","affiliation":[{"name":"Institute of Advanced Orthopedics MOSC Medical College Hospital Kolenchery Kochi Kerala India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rakshit","family":"J","sequence":"additional","affiliation":[{"name":"Institute of Advanced Orthopedics MOSC Medical College Hospital Kolenchery Kochi Kerala India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vyas","family":"Vijayakumar","sequence":"additional","affiliation":[{"name":"Institute of Advanced Orthopedics MOSC Medical College Hospital Kolenchery Kochi Kerala India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saj","family":"Sreejesh","sequence":"additional","affiliation":[{"name":"Institute of Advanced Orthopedics MOSC Medical College Hospital Kolenchery Kochi Kerala India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kiran","family":"Benny","sequence":"additional","affiliation":[{"name":"Institute of Advanced Orthopedics MOSC Medical College Hospital Kolenchery Kochi Kerala India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Prannoy","family":"Paul","sequence":"additional","affiliation":[{"name":"Institute of Advanced Orthopedics MOSC Medical College Hospital Kolenchery Kochi Kerala India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,5,20]]},"reference":[{"key":"e_1_2_3_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.06.008"},{"key":"e_1_2_3_3_1","first-page":"994","article-title":"Treatment of recurrent dislocation of the shoulder","volume":"49","author":"Latarjet M.","year":"1954","journal-title":"Lyon Chir"},{"key":"e_1_2_3_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcot.2015.09.002"},{"key":"e_1_2_3_5_1","doi-asserted-by":"publisher","DOI":"10.1177\/2325967120931399"},{"key":"e_1_2_3_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2010.08.015"},{"key":"e_1_2_3_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2020.10.028"},{"key":"e_1_2_3_8_1","first-page":"189","article-title":"A study on the morphology of the suprascapular notch and its distance from the glenoid cavity","volume":"7","author":"Sangam M.R.","year":"2013","journal-title":"J Clin Diagn Res"},{"key":"e_1_2_3_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jseint.2024.03.020"},{"key":"e_1_2_3_10_1","doi-asserted-by":"publisher","DOI":"10.29271\/jcpsp.2022.10.1356"},{"key":"e_1_2_3_11_1","first-page":"899","article-title":"Arthroscopic allograft bone block procedure with remplissage for bipolar lesions","volume":"10","author":"Memon S.D.","year":"2022","journal-title":"Arch Bone Jt Surg"},{"key":"e_1_2_3_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12178-024-09895-x"},{"key":"e_1_2_3_13_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465231188530"}],"container-title":["Arthroscopy Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S221262872500129X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S221262872500129X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2025.103560","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.eats.2025.103560","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2025.103560","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T11:15:15Z","timestamp":1775733315000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.eats.2025.103560"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,20]]},"references-count":12,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["10.1016\/j.eats.2025.103560"],"URL":"https:\/\/doi.org\/10.1016\/j.eats.2025.103560","archive":["Portico"],"relation":{},"ISSN":["2212-6287","2212-6287"],"issn-type":[{"value":"2212-6287","type":"print"},{"value":"2212-6287","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,20]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Metal-Free Cerclage Method of Arthroscopic Latarjet Using a Printed Poly Lactic Acid Coracoid Protector to Prevent Coracoid Stress Riser While Tensioning","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.eats.2025.103560","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}],"article-number":"103560"}}