{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T20:22:19Z","timestamp":1792700539039,"version":"4.5.0"},"reference-count":8,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T00:00:00Z","timestamp":1747094400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T00:00:00Z","timestamp":1747094400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T00:00:00Z","timestamp":1747094400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T00:00:00Z","timestamp":1747094400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,4,3]],"date-time":"2025-04-03T00:00:00Z","timestamp":1743638400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroscopytechniques.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["arthrosc. tech."],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:label\/>\n                    <jats:p>Rotator cuff injuries are a common cause of shoulder pain, primarily affecting individuals older than 40 years, with the incidence increasing progressively with age. Advancements in surgical techniques have led to the development of arthroscopic techniques. This evolution has transitioned through various arthroscopic suture anchor rotator cuff repair configurations, including single\u2010row, double\u2010row, and transosseous\u2010equivalent constructs. Although these innovations have replicated the biomechanics of the original transosseous technique conducted using an open approach, they often require multiple anchors, significantly increasing surgical costs. Additionally, anchor\u2010related complications persist. To enhance the feasibility and affordability of implant\u2010free transosseous repair, a reusable instrumentation system, was developed by Drillbone (Brno, Czechia). This innovative device facilitates robust and reproducible transosseous rotator cuff repairs while substantially reducing procedural costs. We present a surgical technique using bone tunneling device, showing its application in arthroscopic rotator cuff repair.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique Video<\/jats:title>\n                    <jats:p>\n                      <jats:boxed-text content-type=\"video\" position=\"anchor\">\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" position=\"anchor\" xlink:href=\"urn:x-wiley:22126287:media:atn2bf04113:atn2bf04113-vimg-0001\">\n                          <jats:alt-text>video<\/jats:alt-text>\n                        <\/jats:graphic>\n                      <\/jats:boxed-text>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>See video under supplementary data.<\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.eats.2025.103566","type":"journal-article","created":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T07:51:18Z","timestamp":1747122678000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Arthroscopic Transosseous Rotator Cuff Repair Using Bone Tunneling Device"],"prefix":"10.1002","volume":"14","author":[{"given":"Filip","family":"Hude\u010dek","sequence":"first","affiliation":[{"name":"First Department of Orthopaedic Surgery St. Anne\u2019s University Hospital and Faculty of Medicine Masaryk University Brno Czechia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasileios","family":"Apostolopoulos","sequence":"additional","affiliation":[{"name":"First Department of Orthopaedic Surgery St. Anne\u2019s University Hospital and Faculty of Medicine Masaryk University Brno Czechia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Ku\u017ema","sequence":"additional","affiliation":[{"name":"Department of Traumatology at the Medical Faculty Masaryk University and Trauma Hospital Brno Brno Czechia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jakub","family":"Liskay","sequence":"additional","affiliation":[{"name":"First Department of Orthopaedic Surgery St. Anne\u2019s University Hospital and Faculty of Medicine Masaryk University Brno Czechia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R\u00f3bert","family":"Langer","sequence":"additional","affiliation":[{"name":"First Department of Orthopaedic Surgery St. Anne\u2019s University Hospital and Faculty of Medicine Masaryk University Brno Czechia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom\u00e1\u0161","family":"Tom\u00e1\u0161","sequence":"additional","affiliation":[{"name":"First Department of Orthopaedic Surgery St. Anne\u2019s University Hospital and Faculty of Medicine Masaryk University Brno Czechia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,5,13]]},"reference":[{"key":"e_1_2_3_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546517695789"},{"key":"e_1_2_3_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2016.06.010"},{"key":"e_1_2_3_4_1","doi-asserted-by":"publisher","DOI":"10.1097\/CORR.0000000000001151"},{"key":"e_1_2_3_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2019.07.017"},{"key":"e_1_2_3_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2013.05.011"},{"key":"e_1_2_3_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2012.02.007"},{"key":"e_1_2_3_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2021.12.047"},{"key":"e_1_2_3_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2019.05.012"}],"container-title":["Arthroscopy Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628725001355?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628725001355?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2025.103566","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.eats.2025.103566","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2025.103566","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T11:15:04Z","timestamp":1775733304000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.eats.2025.103566"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,13]]},"references-count":8,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["10.1016\/j.eats.2025.103566"],"URL":"https:\/\/doi.org\/10.1016\/j.eats.2025.103566","archive":["Portico"],"relation":{},"ISSN":["2212-6287","2212-6287"],"issn-type":[{"value":"2212-6287","type":"print"},{"value":"2212-6287","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,13]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Arthroscopic Transosseous Rotator Cuff Repair Using Bone Tunneling Device","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.eats.2025.103566","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}],"article-number":"103566"}}