{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T06:57:47Z","timestamp":1775717867091,"version":"3.50.1"},"reference-count":15,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T00:00:00Z","timestamp":1754956800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T00:00:00Z","timestamp":1754956800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T00:00:00Z","timestamp":1754956800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T00:00:00Z","timestamp":1754956800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,7,15]],"date-time":"2025-07-15T00:00:00Z","timestamp":1752537600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100004331","name":"Johnson and Johnson","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004331","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["arthroscopytechniques.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["arthrosc. tech."],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:label\/>\n                    <jats:p>Rotator cuff tears are one of the most common shoulder pathologies in the adult population, present in approximately 25% of individuals in their 60s and 50% in individuals in their 80s. With several techniques and technological advances in repairing symptomatic rotator cuff tears, the rate of retear rates remains elevated. Synthetic grafts have been developed to aid with rotator cuff repair by providing biomechanical advantage, improved healing at bone tendon interface, while also remaining a cost\u2010effective option when compared with costly revision rates. BioCharge Autobiologic Matrix is a synthetic scaffold approved by the Food and Drug Administration and developed to augment rotator cuff repairs by improving the ultimate load to failure rate while also providing improved enthesis architecture at the tendon\u2010bone interface when observed at a microscopic level. The goal of this Technical Note is to describe the technique of rotator cuff repair with BioCharge augmentation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique Video<\/jats:title>\n                    <jats:p>\n                      <jats:boxed-text content-type=\"video\" position=\"anchor\">\n                        <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" position=\"anchor\" xlink:href=\"urn:x-wiley:22126287:media:atn2bf03793:atn2bf03793-vimg-0001\">\n                          <jats:alt-text>video<\/jats:alt-text>\n                        <\/jats:graphic>\n                      <\/jats:boxed-text>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>See video under supplementary data.<\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.eats.2025.103806","type":"journal-article","created":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T11:26:07Z","timestamp":1754997967000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Rotator Cuff Repair Augmented With a Reinforced Bioabsorbable Autobiologic Matrix"],"prefix":"10.1002","volume":"14","author":[{"given":"Ralfi","family":"Doka","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery McLaren Health Care, Macomb Hospital Mount Clemens Michigan U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dragomir","family":"Mijic","sequence":"additional","affiliation":[{"name":"Center for Bone and Joint Disease Hudson Florida U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian L.","family":"Badman","sequence":"additional","affiliation":[{"name":"Central Indiana Orthopedics Fishers Indiana U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saif L.","family":"Juma","sequence":"additional","affiliation":[{"name":"Michigan State University College of Osteopathic Medicine East Lansing Michigan U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brent","family":"Geers","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery Henry Ford Macomb Hospital Clinton Twp Michigan U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shariff K.","family":"Bishai","sequence":"additional","affiliation":[{"name":"Michigan State University College of Osteopathic Medicine East Lansing Michigan U.S.A."},{"name":"Detroit Orthopedic Institute Troy Michigan U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,8,12]]},"reference":[{"key":"e_1_2_3_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.csm.2012.07.001"},{"key":"e_1_2_3_3_1","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOS-D-23-00101"},{"key":"e_1_2_3_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2009.10.020"},{"key":"e_1_2_3_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2009.12.008"},{"key":"e_1_2_3_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2021.07.018"},{"key":"e_1_2_3_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2018.12.003"},{"key":"e_1_2_3_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514525592"},{"key":"e_1_2_3_9_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546512459477"},{"key":"e_1_2_3_10_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546515624463"},{"key":"e_1_2_3_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2023.04.023"},{"key":"e_1_2_3_12_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm13175066"},{"key":"e_1_2_3_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2022.01.011"},{"key":"e_1_2_3_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2006.06.013"},{"key":"e_1_2_3_15_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.L.01495"},{"key":"e_1_2_3_16_1","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOS-D-19-00500"}],"container-title":["Arthroscopy Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628725003755?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2212628725003755?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2025.103806","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.eats.2025.103806","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.eats.2025.103806","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T06:12:09Z","timestamp":1775715129000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.eats.2025.103806"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,12]]},"references-count":15,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1016\/j.eats.2025.103806"],"URL":"https:\/\/doi.org\/10.1016\/j.eats.2025.103806","archive":["Portico"],"relation":{},"ISSN":["2212-6287","2212-6287"],"issn-type":[{"value":"2212-6287","type":"print"},{"value":"2212-6287","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Rotator Cuff Repair Augmented With a Reinforced Bioabsorbable Autobiologic Matrix","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.eats.2025.103806","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America\u00e9","name":"copyright","label":"Copyright"}],"article-number":"103806"}}