{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T17:30:30Z","timestamp":1786987830341,"version":"build-2736575974"},"reference-count":22,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2014,9,1]],"date-time":"2014-09-01T00:00:00Z","timestamp":1409529600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,9,1]],"date-time":"2014-09-01T00:00:00Z","timestamp":1409529600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","onlinejase.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the American Society of Echocardiography"],"published-print":{"date-parts":[[2014,9]]},"DOI":"10.1016\/j.echo.2014.05.017","type":"journal-article","created":{"date-parts":[[2014,7,3]],"date-time":"2014-07-03T23:45:15Z","timestamp":1404431115000},"page":"984-990","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":36,"title":["Intracardiac Echocardiography during Atrial Septal Defect and Patent Foramen Ovale Device Closure in Pediatric and Adolescent Patients"],"prefix":"10.1016","volume":"27","author":[{"given":"Beth A.","family":"Medford","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathaniel W.","family":"Taggart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Allison K.","family":"Cabalka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Cetta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guy S.","family":"Reeder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donald J.","family":"Hagler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan N.","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.echo.2014.05.017_bib1","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1161\/01.CIR.0000057547.00909.1C","article-title":"Intracardiac echocardiography is superior to conventional monitoring for guiding device closure of interatrial communications","volume":"107","author":"Bartel","year":"2003","journal-title":"Circulation"},{"key":"10.1016\/j.echo.2014.05.017_bib2","doi-asserted-by":"crossref","first-page":"24","DOI":"10.4065\/79.1.24","article-title":"Intracardiac echocardiographic guidance during transcatheter device closure of atrial septal defect and patent foramen ovale","volume":"79","author":"Earing","year":"2004","journal-title":"Mayo Clin Proc"},{"key":"10.1016\/j.echo.2014.05.017_bib3","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1536\/ihj.51.56","article-title":"Stretched size of atrial septal defect predicted by intracardiac echocardiography","volume":"51","author":"Lin","year":"2010","journal-title":"Int Heart J"},{"key":"10.1016\/j.echo.2014.05.017_bib4","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1007\/s002700000397","article-title":"Intracardiac ultrasound assessment of atrial septal defect: comparison with transthoracic echocardiographic, angiocardiographic, and balloon-sizing measurements","volume":"24","author":"Jan","year":"2001","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.echo.2014.05.017_bib5","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/S1726-4901(08)70090-X","article-title":"Sizing of atrial septal defects by intracardiac echocardiography for device closures","volume":"71","author":"Chien","year":"2008","journal-title":"J Chinese Med Assoc"},{"key":"10.1016\/j.echo.2014.05.017_bib6","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1016\/j.amjcard.2004.05.048","article-title":"Comparison of costs of intracardiac echocardiography and transesophageal echocardiography in monitoring percutaneous device closure of atrial septal defect in children and adults","volume":"94","author":"Alboliras","year":"2004","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.echo.2014.05.017_bib7","first-page":"194","article-title":"Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: feasibility and comparison with transesophageal echocardiography","volume":"52","author":"Hijazi","year":"2001","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.echo.2014.05.017_bib8","first-page":"258","article-title":"Initial clinical experience with intracardiac echocardiography in guiding transcatheter closure of perimembranous ventricular septal defects: feasibility and comparison with transesophageal echocardiography","volume":"66","author":"Cao","year":"2005","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.echo.2014.05.017_bib9","doi-asserted-by":"crossref","first-page":"S_930","DOI":"10.1161\/circ.118.suppl_18.S_930-b","article-title":"Prospective comparison of intracardiac versus transoesophageal echocardiography guided closure of patent foramen ovale and atrial septal defects in adults - five year single centre experience","volume":"118","author":"Asrress","year":"2008","journal-title":"Circulation"},{"key":"10.1016\/j.echo.2014.05.017_bib10","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.amjcard.2003.10.037","article-title":"Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect","volume":"93","author":"Boccalandro","year":"2004","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.echo.2014.05.017_bib11","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1017\/S1047951110001861","article-title":"Report from the International Society for Nomenclature of Paediatric and Congenital Heart Disease: cardiovascular catheterisation for congenital\u00a0and paediatric cardiac disease (Part 2-Nomenclature of complications associated with interventional cardiology)","volume":"21","author":"Bergersen","year":"2011","journal-title":"Cardiol Young"},{"key":"10.1016\/j.echo.2014.05.017_bib12","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.1016\/S0140-6736(00)02844-0","article-title":"Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction","volume":"356","author":"Bonhoeffer","year":"2000","journal-title":"Lancet"},{"key":"10.1016\/j.echo.2014.05.017_bib13","series-title":"Echocardiography in pediatric and adult congenital heart disease","first-page":"92","author":"Eidem","year":"2010"},{"key":"10.1016\/j.echo.2014.05.017_bib14","unstructured":"Amplatzer Septal Occluder and delivery system [instructions for use]. Plymouth, MN: AGA Medical Corporation; 2007\u201320012."},{"key":"10.1016\/j.echo.2014.05.017_bib15","series-title":"Gore\u00ae HELEX\u00ae septal occluder [instructions for use]","year":"2013"},{"key":"10.1016\/j.echo.2014.05.017_bib16","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1016\/S0002-9149(01)02316-5","article-title":"Intracardiac echocardiography in the interventional catheterization laboratory: preliminary experience with a novel, phased-array transducer","volume":"89","author":"Bruce","year":"2002","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.echo.2014.05.017_bib17","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/S0735-1097(02)02616-5","article-title":"Intracardiac echocardiography guided device closure of atrial septal defects","volume":"41","author":"Mullen","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.echo.2014.05.017_bib18","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1111\/j.1540-8175.2008.00763.x","article-title":"Transcatheter intracardiac echocardiography-assisted closure of interatrial shunts: complications and midterm follow-up","volume":"26","author":"Rigatelli","year":"2009","journal-title":"Echocardiography"},{"key":"10.1016\/j.echo.2014.05.017_bib19","doi-asserted-by":"crossref","first-page":"474","DOI":"10.5543\/tkda.2011.01576","article-title":"[Intracardiac echocardiography-guided device closure of atrial septal defects: our initial experience]","volume":"39","author":"Akkaya","year":"2011","journal-title":"Turk Kardiyol Dern Ars"},{"key":"10.1016\/j.echo.2014.05.017_bib20","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1161\/01.CIR.0000027819.19722.EE","article-title":"Percutaneous transcatheter closure of patent foramen ovale in patients with paradoxical embolism","volume":"106","author":"Martin","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.echo.2014.05.017_bib21","first-page":"388","article-title":"Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: initial human experience","volume":"42","author":"Masura","year":"1997","journal-title":"Cathet Cardiovasc Diagn"},{"key":"10.1016\/j.echo.2014.05.017_bib22","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1007\/s00246-001-0194-9","article-title":"Intracardiac echocardiography in congenital heart disease: are we ready to begin the fantastic voyage?","volume":"23","author":"O\u2019Leary","year":"2002","journal-title":"Pediatr Cardiol"}],"container-title":["Journal of the American Society of Echocardiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0894731714004349?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0894731714004349?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:53:48Z","timestamp":1760244828000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0894731714004349"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,9]]},"references-count":22,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2014,9]]}},"alternative-id":["S0894731714004349"],"URL":"https:\/\/doi.org\/10.1016\/j.echo.2014.05.017","relation":{},"ISSN":["0894-7317"],"issn-type":[{"value":"0894-7317","type":"print"}],"subject":[],"published":{"date-parts":[[2014,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Intracardiac Echocardiography during Atrial Septal Defect and Patent Foramen Ovale Device Closure in Pediatric and Adolescent Patients","name":"articletitle","label":"Article Title"},{"value":"Journal of the American Society of Echocardiography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.echo.2014.05.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}