{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T01:34:58Z","timestamp":1768872898408,"version":"3.49.0"},"reference-count":15,"publisher":"Oxford University Press (OUP)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["European Journal of Cardio-Thoracic Surgery"],"published-print":{"date-parts":[[2007,4]]},"DOI":"10.1016\/j.ejcts.2006.12.036","type":"journal-article","created":{"date-parts":[[2007,2,8]],"date-time":"2007-02-08T12:07:29Z","timestamp":1170936449000},"page":"698-702","source":"Crossref","is-referenced-by-count":77,"title":["Post-transplant survival after lowering fixed pulmonary hypertension using left ventricular assist devices"],"prefix":"10.1093","volume":"31","author":[{"given":"Daniel","family":"Zimpfer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Zrunek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sigrid","family":"Sandner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heinz","family":"Schima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Grimm","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Zuckermann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ernst","family":"Wolner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Georg","family":"Wieselthaler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","reference":[{"issue":"1","key":"10.1016\/j.ejcts.2006.12.036_bib1","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/0735-1097(92)90050-W","article-title":"Influence of preoperative pulmonary artery pressure on mortality after heart transplantation: testing of potential reversibility of pulmonary hypertension with nitroprusside is useful in defining a high risk group","volume":"19","author":"Costard-Jackle","year":"1992","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ejcts.2006.12.036_bib2","first-page":"526","article-title":"Influence of preoperative transpulmonary gradient on late mortality after orthotopic heart transplantation","volume":"9","author":"Erickson","year":"1990","journal-title":"J Heart Transplant"},{"issue":"6","key":"10.1016\/j.ejcts.2006.12.036_bib3","doi-asserted-by":"crossref","first-page":"1858","DOI":"10.1016\/S0003-4975(00)01318-7","article-title":"Right ventricle-sparing heart transplant: promising new technique for recipients with pulmonary hypertension","volume":"69","author":"Elefteriades","year":"2000","journal-title":"Ann Thorac Surg"},{"issue":"4","key":"10.1016\/j.ejcts.2006.12.036_bib4","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1097\/01.mat.0000169125.21268.d7","article-title":"Left ventricular assist devices as bridge to heart transplantation in congestive heart failure with pulmonary hypertension","volume":"51","author":"Haddad","year":"2005","journal-title":"ASAIO J"},{"issue":"6","key":"10.1016\/j.ejcts.2006.12.036_bib5","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.ejcts.2004.01.052","article-title":"Implantable left ventricular assist device for treatment of pulmonary hypertension in candidates for orthotopic heart transplantation-a preliminary study","volume":"25","author":"Martin","year":"2004","journal-title":"Eur J Cardiothorac Surg"},{"issue":"2","key":"10.1016\/j.ejcts.2006.12.036_bib6","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.ejcts.2004.11.001","article-title":"Normalization of high pulmonary vascular resistance with LVAD support in heart transplantation candidates","volume":"27","author":"Salzberg","year":"2005","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.ejcts.2006.12.036_bib7","unstructured":"Zimpfer D, Zrunek P, Roethy W, Czerny M, Schima H, Huber L, Grimm M, Rajek A, Wolner E, Wieselthaler G. Left ventricular assist devices lower fixed pulmonary hypertension in cardiac Tx candidates. J Thorac Cardiovasc Surg, in press."},{"issue":"20","key":"10.1016\/j.ejcts.2006.12.036_bib8","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1016\/0002-9149(89)90013-1","article-title":"Continuous aortic regurgitation in severely dysfunctional native hearts after heterotopic cardiac transplantation","volume":"63","author":"Akasaka","year":"1989","journal-title":"Am J Cardiol"},{"issue":"8","key":"10.1016\/j.ejcts.2006.12.036_bib9","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1016\/S1053-2498(02)00411-4","article-title":"Determinants of outcome after heterotopic heart transplantation","volume":"21","author":"Bleasdale","year":"2002","journal-title":"J Heart Lung Transplant."},{"issue":"4","key":"10.1016\/j.ejcts.2006.12.036_bib10","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1161\/01.CIR.101.4.356","article-title":"First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation","volume":"101","author":"Wieselthaler","year":"2000","journal-title":"Circulation"},{"issue":"4","key":"10.1016\/j.ejcts.2006.12.036_bib11","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1016\/S0022-5223(94)70282-9","article-title":"Implantation technique for the Novacor left ventricular assist system","volume":"108","author":"Pennington","year":"1994","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"1","key":"10.1016\/j.ejcts.2006.12.036_bib12","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1007\/s10047-004-0284-6","article-title":"Mechanical circulatory support devices (MCSD) in Japan: current status and future directions","volume":"8","author":"Takatani","year":"2005","journal-title":"J Artif Organs"},{"key":"10.1016\/j.ejcts.2006.12.036_bib13","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.1016\/0735-1097(91)90533-F","article-title":"ACC\/AHA guidelines for cardiac catheterizationand cardiac catheterization laboratories. American College of Cardiology\/American Heart Association Ad Hoc Task Force on Cardiac Catheterization","volume":"18","author":"Anonymous","year":"1991","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ejcts.2006.12.036_bib14","first-page":"716","article-title":"Utility of prostaglandin E1 in the pretransplantation evaluation of heart failure patients with significant pulmonary hypertension","volume":"11","author":"Murali","year":"1992","journal-title":"J Heart Lung Transplant"},{"issue":"11","key":"10.1016\/j.ejcts.2006.12.036_bib15","doi-asserted-by":"crossref","first-page":"1764","DOI":"10.1016\/S0735-1097(02)01855-7","article-title":"Implantation of the permanent Jarvik-2000 left ventricular assist device: a single-center experience","volume":"39","author":"Siegenthaler","year":"2002","journal-title":"J Am Coll Cardiol"}],"container-title":["European Journal of Cardio-Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ejcts\/article-pdf\/31\/4\/698\/17775667\/31-4-698.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,20]],"date-time":"2020-04-20T01:52:15Z","timestamp":1587347535000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ejcts\/article-lookup\/doi\/10.1016\/j.ejcts.2006.12.036"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,4]]},"references-count":15,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2007,4]]}},"alternative-id":["S1010794007000073"],"URL":"https:\/\/doi.org\/10.1016\/j.ejcts.2006.12.036","relation":{},"ISSN":["1010-7940"],"issn-type":[{"value":"1010-7940","type":"print"}],"subject":[],"published":{"date-parts":[[2007,4]]}}}