{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T09:17:24Z","timestamp":1791191844179,"version":"4.1.0"},"reference-count":33,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T00:00:00Z","timestamp":1398902400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2014,5]]},"DOI":"10.1016\/j.ejmp.2013.09.001","type":"journal-article","created":{"date-parts":[[2013,10,3]],"date-time":"2013-10-03T10:15:19Z","timestamp":1380795319000},"page":"301-308","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":21,"title":["Evaluation of the Block Matching deformable registration algorithm in\u00a0the field of head-and-neck adaptive radiotherapy"],"prefix":"10.1016","volume":"30","author":[{"given":"S.","family":"Huger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Graff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Harter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Marchesi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Royer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.C.","family":"Diaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Aouadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Wolf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Peiffert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Noel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejmp.2013.09.001_bib1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.radonc.2008.04.010","article-title":"Comparison of 12 deformable registration strategies in adaptive radiation therapy for the treatment of head and neck tumors","volume":"89","author":"Castadot","year":"2008","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2013.09.001_bib2","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.radonc.2011.09.024","article-title":"Does IGRT ensure target dose coverage of head and neck IMRT patients?","volume":"104","author":"Graff","year":"2012","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2013.09.001_bib3","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/j.ijrobp.2012.10.040","article-title":"The Residual Setup Errors of Different IGRT Alignment Procedures for Head and Neck IMRT and the Resulting Dosimetric Impact","volume":"86","author":"Graff","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib4","doi-asserted-by":"crossref","first-page":"S15","DOI":"10.1016\/j.ejmp.2011.06.033","article-title":"Adaptative radiotherapy in the head and neck cancers","volume":"27","author":"Huger","year":"2011","journal-title":"Physica medica"},{"key":"10.1016\/j.ejmp.2013.09.001_bib5","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1016\/j.ijrobp.2006.10.048","article-title":"Dose calculation using megavoltage cone-beam CT","volume":"67","author":"Morin","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib6","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1078\/0939-3889-00327","article-title":"Deformable registration for image-guided radiation therapy","volume":"16","author":"Sarrut","year":"2006","journal-title":"Z Med Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib7","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1016\/S0262-8856(03)00137-9","article-title":"Image registration methods: a survey","volume":"21","author":"Zitov\u00e1","year":"2003","journal-title":"Image and Vision Computing"},{"key":"10.1016\/j.ejmp.2013.09.001_bib8","doi-asserted-by":"crossref","first-page":"2088","DOI":"10.1118\/1.3554647","article-title":"Deformable planning CT to cone-beam CT image registration in head-and-neck cancer","volume":"38","author":"Hou","year":"2011","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib9","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.ijrobp.2004.07.677","article-title":"Implementation and validation of a three-dimensional deformable registration algorithm for targeted prostate cancer radiotherapy","volume":"61","author":"Wang","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib10","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1016\/j.ijrobp.2007.01.038","article-title":"Automatic delineation of on-line head-and-neck computed tomography images: toward on-line adaptive radiotherapy","volume":"68","author":"Zhang","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib11","doi-asserted-by":"crossref","first-page":"4755","DOI":"10.1118\/1.3223631","article-title":"Demons deformable registration for CBCT-guided procedures in the head and neck: convergence and accuracy","volume":"36","author":"Nithiananthan","year":"2009","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib12","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1118\/1.2836417","article-title":"A deformable phantom for 4D radiotherapy verification: design and image registration evaluation","volume":"35","author":"Serban","year":"2008","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib13","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1007\/978-3-540-40899-4_57","article-title":"Block Matching: A general Framework to Improve Robustness of Rigid Registration of Medical Images","volume":"1935","author":"Ourselin","year":"2000","journal-title":"Lect Notes Comput Sci."},{"key":"10.1016\/j.ejmp.2013.09.001_bib14","first-page":"137","article-title":"A robust and Efficient Block-Matching Framework for Non-linear Registration of Thoracic CT images","author":"Garcia","year":"2010","journal-title":"Medical Image Analysis for the Clinic: A Grand Challenge"},{"issue":"Suppl. 1","key":"10.1016\/j.ejmp.2013.09.001_bib15","doi-asserted-by":"crossref","first-page":"S20","DOI":"10.1016\/j.ejmp.2011.06.045","article-title":"Adaptive Radiotherapy: non rigid registration methods","volume":"27","author":"Malandain","year":"2011","journal-title":"Physica Medica"},{"key":"10.1016\/j.ejmp.2013.09.001_bib16","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.radonc.2006.05.009","article-title":"Changes in lateral dimensions of irradiated volume and their impact on the accuracy of dose delivery during radiotherapy for head and neck cancer","volume":"79","author":"Senkus-Konefka","year":"2006","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2013.09.001_bib17","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.radonc.2010.03.007","article-title":"Assessment by a deformable registration method of the volumetric and positional changes of target volumes and organs at risk in pharyngo-laryngeal tumors treated with concomitant chemo-radiation","volume":"95","author":"Castadot","year":"2010","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2013.09.001_bib18","doi-asserted-by":"crossref","first-page":"297","DOI":"10.2307\/1932409","article-title":"Measures of the Amount of Ecologic Association Between Species","volume":"26","author":"Lr","year":"1945","journal-title":"Ecology"},{"key":"10.1016\/j.ejmp.2013.09.001_bib19","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/j.radonc.2009.08.013","article-title":"A pre-clinical assessment of an atlas-based automatic segmentation tool for the head and neck","volume":"93","author":"Sims","year":"2009","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2013.09.001_bib20","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1109\/34.232073","article-title":"Comparing Images Using the Hausdorff Distance","volume":"15","author":"Huttenlocher","year":"1993","journal-title":"IEEE Transactions of pattern analysis and machine intelligence"},{"key":"10.1016\/j.ejmp.2013.09.001_bib21","doi-asserted-by":"crossref","first-page":"963","DOI":"10.2307\/2529876","article-title":"Random-effects models for longitudinal data","volume":"38","author":"Laird","year":"1982","journal-title":"Biometrics"},{"key":"10.1016\/j.ejmp.2013.09.001_bib22","first-page":"1014","article-title":"Newton-Raphson and EM Algorithms for Linear Mixed-Effects Models for Repeated-Measures Data","volume":"83","author":"Lindstrom","year":"1988","journal-title":"Journal of the American Statistical Association"},{"key":"10.1016\/j.ejmp.2013.09.001_bib23","doi-asserted-by":"crossref","first-page":"1785","DOI":"10.1118\/1.3555037","article-title":"Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach","volume":"38","author":"Nithiananthan","year":"2011","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib24","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/S1361-8415(98)80022-4","article-title":"Image matching as a diffusion process: an analogy with Maxwell's demons","volume":"2","author":"Thirion","year":"1998","journal-title":"Med Image Anal"},{"key":"10.1016\/j.ejmp.2013.09.001_bib25","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1118\/1.1339879","article-title":"Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter","volume":"28","author":"Siewerdsen","year":"2001","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib26","doi-asserted-by":"crossref","first-page":"3067","DOI":"10.1088\/0031-9155\/49\/14\/003","article-title":"Fast free-form deformable registration via calculus of variations","volume":"49","author":"Lu","year":"2004","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2013.09.001_bib27","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S1361-8415(02)00063-4","article-title":"Image registration via level-set motion: applications to atlas-based segmentation","volume":"7","author":"Vemuri","year":"2003","journal-title":"Med Image Anal"},{"key":"10.1016\/j.ejmp.2013.09.001_bib28","doi-asserted-by":"crossref","first-page":"4066","DOI":"10.1120\/jacmp.v14i1.4066","article-title":"A framework for deformable image registration validation in radiotherapy clinical applications","volume":"14","author":"Varadhan","year":"2013","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib29","doi-asserted-by":"crossref","first-page":"6491","DOI":"10.1088\/0031-9155\/55\/21\/010","article-title":"Biomechanical-based image registration for head and neck radiation treatment","volume":"55","author":"Al-Mayah","year":"2010","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2013.09.001_bib30","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.ijrobp.2009.06.012","article-title":"Dosimetric evaluation of automatic segmentation for adaptive IMRT for head-and-neck cancer","volume":"77","author":"Tsuji","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib31","doi-asserted-by":"crossref","first-page":"1858","DOI":"10.1016\/j.ijrobp.2011.03.035","article-title":"Dentalmaps: automatic dental delineation for radiotherapy planning in head-and-neck cancer","volume":"82","author":"Thariat","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib32","doi-asserted-by":"crossref","first-page":"3888","DOI":"10.1120\/jacmp.v14i1.3888","article-title":"A study on image quality provided by a kilovoltage cone-beam computed tomography","volume":"14","author":"Garayoa","year":"2013","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2013.09.001_bib33","doi-asserted-by":"crossref","first-page":"4583","DOI":"10.1118\/1.3597881","article-title":"A two-dimensional deformable phantom for quantitatively verifying deformation algorithms","volume":"38","author":"Kirby","year":"2011","journal-title":"Med Phys"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179713003967?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179713003967?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,7,28]],"date-time":"2019-07-28T18:53:48Z","timestamp":1564340028000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179713003967"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,5]]}},"alternative-id":["S1120179713003967"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2013.09.001","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2014,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of the Block Matching deformable registration algorithm in\u00a0the field of head-and-neck adaptive radiotherapy","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2013.09.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Associazione Italiana di Fisica Medica. Published by Associazione Italiana di Fisica in Medicina All rights reserved.","name":"copyright","label":"Copyright"}]}}