{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T13:17:57Z","timestamp":1787318277116,"version":"build-2736575974"},"reference-count":14,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2016,12,1]],"date-time":"2016-12-01T00:00:00Z","timestamp":1480550400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["physicamedica.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2016,12]]},"DOI":"10.1016\/j.ejmp.2016.11.007","type":"journal-article","created":{"date-parts":[[2016,11,23]],"date-time":"2016-11-23T21:46:49Z","timestamp":1479937609000},"page":"1846-1851","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"title":["Development of Monte Carlo based real-time treatment planning system with fast calculation algorithm for boron neutron capture therapy"],"prefix":"10.1016","volume":"32","author":[{"given":"Kenta","family":"Takada","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroaki","family":"Kumada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng Hong","family":"Liem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideyuki","family":"Sakurai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeji","family":"Sakae","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejmp.2016.11.007_b0005","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.apradiso.2014.02.018","article-title":"Project for the development of the linac based NCT facility in University of Tsukuba","volume":"88","author":"Kumada","year":"2014","journal-title":"Appl Radiat Isot"},{"key":"10.1016\/j.ejmp.2016.11.007_b0010","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.apradiso.2015.08.032","article-title":"Verification of nuclear data for the Tsukuba plan, a newly developed treatment planning system for boron neutron capture therapy","volume":"106","author":"Kumada","year":"2015","journal-title":"Appl Radiat Isot"},{"key":"10.1016\/j.ejmp.2016.11.007_b0015","first-page":"381","article-title":"Patient positioning in static beams for boron neutron capture therapy of malignant glioma","volume":"18","author":"Wielopolski","year":"2000","journal-title":"Radiat Med"},{"key":"10.1016\/j.ejmp.2016.11.007_b0020","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1016\/j.apradiso.2004.05.050","article-title":"Development and application of an unconstrained technique for patient positioning in fixed radiation beams","volume":"61","author":"Kiger","year":"2004","journal-title":"Appl Radiat Isot"},{"key":"10.1016\/j.ejmp.2016.11.007_b0025","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1007\/s12094-014-1200-z","article-title":"A prospective analysis of inter- and intrafractional errors to calculate CTV to PTV margins in head and neck patients","volume":"17","author":"Cacicedo","year":"2015","journal-title":"Clin Transl Oncol"},{"key":"10.1016\/j.ejmp.2016.11.007_b0030","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.radonc.2014.09.008","article-title":"An assessment of the magnitude of intra-fraction movement of head-and-neck IMRT cases and its implication on the action-level of the imaging protocol","volume":"112","author":"Pang","year":"2014","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2016.11.007_b0035","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1093\/rpd\/ncu357","article-title":"Whole-body dose evaluation with an adaptive treatment planning system for boron neutron capture therapy","volume":"167","author":"Takada","year":"2015","journal-title":"Radiat Prot Dosimetry"},{"key":"10.1016\/j.ejmp.2016.11.007_b0040","doi-asserted-by":"crossref","first-page":"3353","DOI":"10.1088\/0031-9155\/49\/15\/003","article-title":"Verification of the computational dosimetry system in JAERI (JCDS) for boron neutron capture therapy","volume":"49","author":"Kumada","year":"2004","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2016.11.007_b0045","doi-asserted-by":"crossref","first-page":"1882","DOI":"10.1016\/j.apradiso.2011.03.036","article-title":"Investigation of irradiation conditions for recurrent breast cancer in JRR-4","volume":"69","author":"Horiguchi","year":"2011","journal-title":"Appl Radiat Isot"},{"key":"10.1016\/j.ejmp.2016.11.007_b0050","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1080\/00223131.2013.814553","article-title":"Particle and heavy ion transport code system, PHITS, version 2.52","volume":"50","author":"Sato","year":"2013","journal-title":"J Nucl Sci Technol"},{"key":"10.1016\/j.ejmp.2016.11.007_b0055","first-page":"1","article-title":"Development and verification of BATAN\u2019S Standard, two-dimensional multigroup neutron diffusion codes (BATAN-2DIFF)","volume":"20","author":"Liem","year":"1994","journal-title":"Atom Indonesia"},{"key":"10.1016\/j.ejmp.2016.11.007_b0060","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1016\/j.apradiso.2004.05.035","article-title":"Measurement of free beam neutron spectra at eight BNCT facilities worldwide","volume":"61","author":"Auterinen","year":"2004","journal-title":"Appl Radiat Isot"},{"key":"10.1016\/j.ejmp.2016.11.007_b0065","doi-asserted-by":"crossref","first-page":"2328","DOI":"10.1118\/1.1509444","article-title":"The medical-irradiation characteristics for neutron capture therapy at the heavy water neutron irradiation facility of Kyoto University Research Reactor","volume":"29","author":"Sakurai","year":"2002","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2016.11.007_b0070","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.ejmp.2013.07.001","article-title":"Computational assessment of deep-seated tumor treatment capability of the 9Be(d, n)10B reaction for accelerator-based boron neutron capture therapy (AB-BNCT)","volume":"30","author":"Capoulat","year":"2014","journal-title":"Phys Med"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179716309814?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179716309814?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,6]],"date-time":"2018-09-06T08:25:53Z","timestamp":1536222353000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179716309814"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12]]},"references-count":14,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2016,12]]}},"alternative-id":["S1120179716309814"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2016.11.007","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2016,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Development of Monte Carlo based real-time treatment planning system with fast calculation algorithm for boron neutron capture therapy","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2016.11.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}