{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T05:27:38Z","timestamp":1768973258461,"version":"3.49.0"},"reference-count":31,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,12,1]],"date-time":"2017-12-01T00:00:00Z","timestamp":1512086400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["physicamedica.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2017,12]]},"DOI":"10.1016\/j.ejmp.2017.11.007","type":"journal-article","created":{"date-parts":[[2017,11,20]],"date-time":"2017-11-20T05:45:57Z","timestamp":1511156757000},"page":"58-65","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"special_numbering":"C","title":["Comparison of different treatment planning optimization methods for vaginal HDR brachytherapy with multichannel applicators: A reduction of the high doses to the vaginal mucosa is possible"],"prefix":"10.1016","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2193-2814","authenticated-orcid":false,"given":"Mauro","family":"Carrara","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Davide","family":"Cusumano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tommaso","family":"Giandini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chiara","family":"Tenconi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ester","family":"Mazzarella","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simone","family":"Grisotto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eleonora","family":"Massari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Davide","family":"Mazzeo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annamaria","family":"Cerrotta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brigida","family":"Pappalardi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo","family":"Fallai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emanuele","family":"Pignoli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejmp.2017.11.007_b0005","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.ygyno.2005.11.004","article-title":"Salvage treatment with high-dose-rate brachytherapy for isolated vaginal endometrial cancer recurrence","volume":"101","author":"Petignat","year":"2006","journal-title":"Gynecol Oncol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0010","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1186\/1748-717X-3-7","article-title":"High-dose rate brachytherapy (HDRB) for primary or recurrent cancer in the vagina","volume":"13","author":"Beriwal","year":"2008","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0015","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1259\/bjr.73.875.11144798","article-title":"Radiotherapy for vaginal carcinoma: a 23-year review","volume":"73","author":"Stryker","year":"2000","journal-title":"Br J Radiol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0020","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1016\/j.ygyno.2008.07.007","article-title":"Twenty-year review of radiotherapy for vaginal cancer: an institutional experience","volume":"111","author":"Lian","year":"2008","journal-title":"Gynecol Oncol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0025","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.brachy.2011.06.008","article-title":"American Brachytherapy Society consensus guidelines for interstitial brachytherapy for vaginal cancer","volume":"11","author":"Beriwal","year":"2012","journal-title":"Brachytherapy"},{"key":"10.1016\/j.ejmp.2017.11.007_b0030","doi-asserted-by":"crossref","first-page":"1698","DOI":"10.1016\/j.ejmp.2016.08.016","article-title":"3D-printed applicators for high dose rate brachytherapy: dosimetric assessment at different infill percentage","volume":"32","author":"Ricotti","year":"2016","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2017.11.007_b0035","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/S0360-3016(98)00453-2","article-title":"The use and advantages of a multi-channel vaginal cylinder in high-dose-rate brachytherapy","volume":"44","author":"Demanes","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2017.11.007_b0040","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.radonc.2003.11.006","article-title":"Multi-channel intracavitary vaginal brachytherapy using three-dimensional optimization of source geometry","volume":"70","author":"Tanderup","year":"2004","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0045","doi-asserted-by":"crossref","first-page":"S108","DOI":"10.1016\/S0167-8140(12)72236-3","article-title":"Comparing classic and multichannel cylindrical vaginal applicators in intracavitary gynaecologic brachytherapy","volume":"103","author":"Cerrotta","year":"2012","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0050","doi-asserted-by":"crossref","first-page":"362","DOI":"10.5114\/jcb.2014.47816","article-title":"Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning","volume":"6","author":"Bahadur","year":"2014","journal-title":"J Contemp Brachytherapy"},{"key":"10.1016\/j.ejmp.2017.11.007_b0055","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejmp.2017.05.003","article-title":"Clinical application of MOSkin dosimeters to rectal wall in vivo dosimetry in gynecological HDR brachytherapy","author":"Carrara","year":"2017","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2017.11.007_b0060","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.brachy.2014.10.001","article-title":"Image-based multichannel vaginal cylinder brachytherapy for vaginal cancer","volume":"14","author":"Vargo","year":"2015","journal-title":"Brachytherapy"},{"key":"10.1016\/j.ejmp.2017.11.007_b0065","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/j.brachy.2013.01.117","article-title":"Dosimetric comparison of multi-channel vaginal cylinder high-dose-rate brachytherapy to one single channel vaginal cylinder for patients with vaginal cancer","volume":"12","author":"Kim","year":"2013","journal-title":"Brachytherapy"},{"key":"10.1016\/j.ejmp.2017.11.007_b0070","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.3109\/0284186X.2014.928829","article-title":"Dosimetric evaluation of manually and inversely optimized treatment planning for high dose brachytherapy of cervical cancer","volume":"53","author":"Palmqvist","year":"2014","journal-title":"Acta Oncol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0075","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.brachy.2013.04.009","article-title":"Dosimetric comparison of optimization methods for multichannel intracavitary brachytherapy for superficial vaginal tumors","volume":"12","author":"Lapuz","year":"2013","journal-title":"Brachytherapy"},{"key":"10.1016\/j.ejmp.2017.11.007_b0080","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1118\/1.1368127","article-title":"Inverse planning anatomy-based dose optimization for HDR-Brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function","volume":"28","author":"Lessard","year":"2001","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2017.11.007_b0085","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/S0167-8140(05)81018-7","article-title":"HIPO: a hybrid inverse treatment planning optimization algorithm in HDR brachytherapy","volume":"76","author":"Karabis","year":"2005","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0090","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/S0167-8140(02)00384-5","article-title":"The irradiation tolerance dose of the proximal vagina","volume":"67","author":"Au","year":"2003","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0095","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.ijrobp.2014.01.032","article-title":"Manifestation pattern of early-late vaginal morbidity after definitive radiation (chemo)therapy and image-guided adaptive brachytherapy for locally advanced cervical cancer: an analysis from the EMBRACE study","volume":"1","author":"Kirchheiner","year":"2014","journal-title":"Int Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2017.11.007_b0100","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.radonc.2009.10.004","article-title":"New inverse planning technology for image-guided cervical cancer brachytherapy: description and evaluation within a clinical frame","volume":"93","author":"Trnkov\u00e1","year":"2009","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0105","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1118\/1.1646040","article-title":"Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations","volume":"31","author":"Rivard","year":"2004","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2017.11.007_b0110","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1016\/j.ejmp.2016.09.004","article-title":"Heterogeneity and scatter effects on Ir-192 brachytherapy dose distribution","volume":"32","author":"Osman","year":"2016","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2017.11.007_b0115","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.brachy.2014.09.006","article-title":"A comparison of inverse optimization algorithms for HDR\/PDR prostate brachytherapy treatment planning","volume":"14","author":"Dinkla","year":"2015","journal-title":"Brachytherapy"},{"key":"10.1016\/j.ejmp.2017.11.007_b0120","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1118\/1.596152","article-title":"A dose homogeneity index for evaluating 192Ir interstitial breast implants","volume":"15","author":"Wu","year":"1998","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2017.11.007_b0125","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/S0360-3016(97)00732-3","article-title":"A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy","volume":"40","author":"Baltas","year":"1998","journal-title":"Int J Rad Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2017.11.007_b0130","unstructured":"International Commission on Radiation Units and Measurements (ICRU) 38 report. Dose and Volume Specification for Reporting Intracavitary Therapy in Gynecology; 1985."},{"key":"10.1016\/j.ejmp.2017.11.007_b0135","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.brachy.2011.08.005","article-title":"American Brachytherapy Society consensus guidelines for adjuvant vaginal cuff brachytherapy after hysterectomy","volume":"11","author":"Small","year":"2012","journal-title":"Brachytherapy"},{"key":"10.1016\/j.ejmp.2017.11.007_b0140","unstructured":"International Commission on Radiation Units and Measurements (ICRU) 89 report. Prescribing, Recording, and Reporting Brachytherapy for Cancer of the Cervix; 2016."},{"key":"10.1016\/j.ejmp.2017.11.007_b0145","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.radonc.2013.11.002","article-title":"Review of clinical brachytherapy uncertainties: Analysis guidelines of GEC-ESTRO and the AAPM","volume":"110","author":"Kirisits","year":"2014","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2017.11.007_b0150","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1016\/S0360-3016(02)03802-6","article-title":"Inverse planning for interstitial gynecologic template brachytherapy: truly anatomy-based planning","volume":"54","author":"Lessard","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2017.11.007_b0155","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1016\/j.brachy.2015.08.009","article-title":"Multichannel vaginal cylinder brachytherapy-Impact of tumor thickness and location on dose to organs at risk","volume":"14","author":"Glaser","year":"2015","journal-title":"Brachytherapy"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179717306002?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179717306002?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,8,25]],"date-time":"2018-08-25T20:07:03Z","timestamp":1535227623000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179717306002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12]]},"references-count":31,"alternative-id":["S1120179717306002"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2017.11.007","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2017,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of different treatment planning optimization methods for vaginal HDR brachytherapy with multichannel applicators: A reduction of the high doses to the vaginal mucosa is possible","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2017.11.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}