{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T05:42:21Z","timestamp":1778823741368,"version":"3.51.4"},"reference-count":20,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,12,1]],"date-time":"2018-12-01T00:00:00Z","timestamp":1543622400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100009619","name":"AMED","doi-asserted-by":"publisher","award":["16ck0106033h0003"],"award-info":[{"award-number":["16ck0106033h0003"]}],"id":[{"id":"10.13039\/100009619","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"JSPS","doi-asserted-by":"publisher","award":["18J12886"],"award-info":[{"award-number":["18J12886"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["physicamedica.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1016\/j.ejmp.2018.11.010","type":"journal-article","created":{"date-parts":[[2018,11,27]],"date-time":"2018-11-27T17:40:20Z","timestamp":1543340420000},"page":"66-73","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"special_numbering":"C","title":["Range optimization for target and organs at risk in dynamic adaptive passive scattering proton beam therapy \u2013 A proof of concept"],"prefix":"10.1016","volume":"56","author":[{"given":"Shunsuke","family":"Moriya","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hidenobu","family":"Tachibana","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenji","family":"Hotta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoki","family":"Nakamura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeji","family":"Sakae","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuo","family":"Akimoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejmp.2018.11.010_b0005","doi-asserted-by":"crossref","first-page":"R491","DOI":"10.1088\/0031-9155\/51\/13\/R26","article-title":"Proton therapy","volume":"51","author":"Smith","year":"2006","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2018.11.010_b0010","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1016\/j.ijrobp.2006.01.052","article-title":"Significant reduction of normal tissue dose by proton radiotherapy compared with three-dimensional conformal or intensity-modulated radiation therapy in Stage I or Stage III non-small-cell lung cancer","volume":"65","author":"Chang","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2018.11.010_b0015","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/S0167-8140(99)00036-5","article-title":"A treatment planning inter-comparison of proton and intensity modulated photon radiotherapy","volume":"51","author":"Lomax","year":"1999","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2018.11.010_b0020","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.ijrobp.2008.05.011","article-title":"Quantification and visualization of charged particle range variations","volume":"72","author":"Mori","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2018.11.010_b0025","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1118\/1.3021139","article-title":"Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning","volume":"36","author":"Unkelbach","year":"2009","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2018.11.010_b0030","doi-asserted-by":"crossref","DOI":"10.1118\/1.4801910","article-title":"A novel dose-based positioning method for CT image-guided proton therapy","volume":"40","author":"Cheung","year":"2013","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2018.11.010_b0035","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1016\/j.radonc.2016.01.004","article-title":"First clinical application of a prompt gamma based in vivo proton range verification system","volume":"118","author":"Richter","year":"2016","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2018.11.010_b0040","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1016\/j.ijrobp.2010.08.006","article-title":"Interfractional variations in the setup of pelvic bony anatomy and soft tissue, and their implications on the delivery of proton therapy for localized prostate cancer","volume":"80","author":"Trofimov","year":"2011","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2018.11.010_b0045","doi-asserted-by":"crossref","first-page":"4947","DOI":"10.1088\/0031-9155\/56\/15\/019","article-title":"Introducing an on-line adaptive procedure for prostate image guided intensity modulate proton therapy","volume":"56","author":"Zhang","year":"2011","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2018.11.010_b0050","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1016\/j.ijrobp.2014.06.057","article-title":"Contrast-enhanced proton radiography for patient set-up by using x-ray CT prior knowledge","volume":"90","author":"Spadea","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2018.11.010_b0055","doi-asserted-by":"crossref","first-page":"4474","DOI":"10.1002\/mp.12444","article-title":"Feasibility of dynamic adaptive passive scattering proton therapy with computed tomography image guidance in the lung","volume":"44","author":"Moriya","year":"2017","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2018.11.010_b0060","first-page":"1","article-title":"Preface","volume":"7","author":"Deluca","year":"2007","journal-title":"J ICRU"},{"key":"10.1016\/j.ejmp.2018.11.010_b0065","doi-asserted-by":"crossref","first-page":"1570","DOI":"10.1016\/j.ijrobp.2009.05.035","article-title":"Critical appraisal of volumetric modulated arc therapy in stereotactic body radiation therapy for metastases to abdominal lymph nodes","volume":"75","author":"Bignardi","year":"2009","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2018.11.010_b0070","first-page":"108","article-title":"Evaluation of normal tissue exposure in patients receiving radiotherapy for pancreatic cancer based on RTOG 0848","volume":"6","author":"Ling","year":"2015","journal-title":"J Gastrointest Oncol"},{"key":"10.1016\/j.ejmp.2018.11.010_b0075","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1016\/S0360-3016(02)04151-2","article-title":"Intensity-modulated radiation therapy: a novel approach to the management of malignant pleural mesothelioma","volume":"55","author":"Ahamad","year":"2003","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2018.11.010_b0080","doi-asserted-by":"crossref","first-page":"N287","DOI":"10.1088\/0031-9155\/56\/22\/N03","article-title":"Clinical implementation of a GPU-based simplified Monte Carlo method for a treatment planning system of proton beam therapy","volume":"56","author":"Kohno","year":"2011","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2018.11.010_b0085","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1016\/j.ijrobp.2012.02.041","article-title":"Adaptive\/nonadaptive proton radiation planning and outcomes in a phase II trial for locally advanced non-small cell lung cancer","volume":"84","author":"Koay","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2018.11.010_b0090","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.ejmp.2016.12.011","article-title":"Characterization of prompt gamma-ray emission with respect to the Bragg peak for proton beam range verification: a Monte Carlo study","volume":"33","author":"Zarifi","year":"2017","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2018.11.010_b0095","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/j.ejmp.2014.04.003","article-title":"Proton range monitoring with in-beam PET: Monte Carlo activity predictions and comparison with cyclotron data","volume":"30","author":"Kraan","year":"2014","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2018.11.010_b0100","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.ejmp.2017.01.003","article-title":"Spectroscopic study of prompt-gamma emission for range verification in proton therapy","volume":"34","author":"Kelleter","year":"2017","journal-title":"Phys Med"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179718313267?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179718313267?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,12,6]],"date-time":"2018-12-06T03:11:14Z","timestamp":1544065874000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179718313267"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12]]},"references-count":20,"alternative-id":["S1120179718313267"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2018.11.010","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2018,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Range optimization for target and organs at risk in dynamic adaptive passive scattering proton beam therapy \u2013 A proof of concept","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2018.11.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}