{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T22:15:35Z","timestamp":1761171335727,"version":"build-2065373602"},"reference-count":25,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T00:00:00Z","timestamp":1646092800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T00:00:00Z","timestamp":1646092800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,3,17]],"date-time":"2024-03-17T00:00:00Z","timestamp":1710633600000},"content-version":"am","delay-in-days":747,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2022,3]]},"DOI":"10.1016\/j.ejmp.2022.01.007","type":"journal-article","created":{"date-parts":[[2022,1,28]],"date-time":"2022-01-28T20:46:27Z","timestamp":1643402787000},"page":"57-63","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Comparison of the effects of varying tube voltage and iodinated concentration on increasing the iodinated radiation dose in computed tomography"],"prefix":"10.1016","volume":"95","author":[{"given":"Minori","family":"Hoshika","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Nakaura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seitaro","family":"Oda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masafumi","family":"Kidoh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasunori","family":"Nagayama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Sakabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshinori","family":"Hirai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinori","family":"Funama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.ejmp.2022.01.007_b0005","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1148\/radiol.2020202317","article-title":"Improving Image Quality and Reducing Radiation Dose for Pediatric CT by Using Deep Learning Reconstruction","volume":"298","author":"Brady","year":"2021","journal-title":"Radiology"},{"issue":"2","key":"10.1016\/j.ejmp.2022.01.007_b0010","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1148\/radiol.11110021","article-title":"Abdominal dynamic CT in patients with renal dysfunction: contrast agent dose reduction with low tube voltage and high tube current-time product settings at 256-detector row CT","volume":"261","author":"Nakaura","year":"2011","journal-title":"Radiology"},{"key":"10.1016\/j.ejmp.2022.01.007_b0015","doi-asserted-by":"crossref","first-page":"4262","DOI":"10.1002\/mp.12314","article-title":"Estimating patient dose from CT exams that use automatic exposure control: Development and validation of methods to accurately estimate tube current values","volume":"44","author":"McMillan","year":"2017","journal-title":"Med Phys."},{"issue":"4","key":"10.1016\/j.ejmp.2022.01.007_b0020","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1016\/j.ejmp.2014.02.005","article-title":"Image quality assessment of an iterative reconstruction algorithm applied to abdominal CT imaging","volume":"30","author":"Funama","year":"2014","journal-title":"Phys Med."},{"issue":"5","key":"10.1016\/j.ejmp.2022.01.007_b0025","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1097\/RCT.0000000000000488","article-title":"A Comparison of the Image Quality and Radiation Dose Using 100-kVp Combination of Different Noise Index and 120-kVp in Computed Tomography Pulmonary Angiography","volume":"40","author":"Zhao","year":"2016","journal-title":"J Comput Assist Tomogr."},{"issue":"2","key":"10.1016\/j.ejmp.2022.01.007_b0030","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.acra.2014.07.025","article-title":"Low-concentration contrast medium for 128-slice dual-source CT coronary angiography at a very low radiation dose using prospectively ECG-triggered high-pitch spiral acquisition","volume":"22","author":"Zheng","year":"2015","journal-title":"Acad Radiol."},{"issue":"6","key":"10.1016\/j.ejmp.2022.01.007_b0035","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.2214\/AJR.12.8958","article-title":"Can contrast media increase organ doses in CT examinations? A clinical study","volume":"200","author":"Amato","year":"2013","journal-title":"AJR Am J Roentgenol."},{"issue":"3","key":"10.1016\/j.ejmp.2022.01.007_b0040","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1148\/radiol.2017152852","article-title":"The Effect of Contrast Material on Radiation Dose at CT: Part II. A Systematic Evaluation across 58 Patient Models","volume":"283","author":"Sahbaee","year":"2017","journal-title":"Radiology"},{"issue":"1","key":"10.1016\/j.ejmp.2022.01.007_b0045","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1007\/s00330-017-4970-1","article-title":"The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging: Implications for CT dosimetry","volume":"28","author":"Perisinakis","year":"2018","journal-title":"Eur Radiol."},{"key":"10.1016\/j.ejmp.2022.01.007_b0050","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.ejmp.2018.02.001","article-title":"The impact of iodinated contrast media on intravascular and extravascular absorbed doses in X-ray imaging: A microdosimetric analysis","volume":"46","author":"Harbron","year":"2018","journal-title":"Phys Med."},{"key":"10.1016\/j.ejmp.2022.01.007_b0055","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.ejmp.2018.05.009","article-title":"What is the underestimation of radiation dose to the pediatric thyroid gland from contrast enhanced CT, if contrast medium uptake is not taken into account?","volume":"49","author":"Perisinakis","year":"2018","journal-title":"Phys Med."},{"key":"10.1016\/j.ejmp.2022.01.007_b0060","doi-asserted-by":"crossref","unstructured":"W. Cai C. Hu S. Hu X. Wang J. Gong W. Zhang et al. Feasibility study of iterative model reconstruction combined with low tube voltage, low iodine load, and low iodine delivery rate in craniocervical CT angiography Clin Radiol. 73 2 2018 217.e1 217.e6.","DOI":"10.1016\/j.crad.2017.09.009"},{"issue":"12","key":"10.1016\/j.ejmp.2022.01.007_b0065","doi-asserted-by":"crossref","first-page":"2454","DOI":"10.1016\/j.ejrad.2015.09.010","article-title":"Low tube voltage computed tomography urography using low-concentration contrast media: Comparison of image quality in conventional computed tomography urography","volume":"84","author":"Hwang","year":"2015","journal-title":"Eur J Radiol."},{"issue":"2","key":"10.1016\/j.ejmp.2022.01.007_b0070","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1148\/radiol.2432050808","article-title":"Coronary artery calcium: a multi-institutional, multimanufacturer international standard for quantification at cardiac CT","volume":"243","author":"McCollough","year":"2007","journal-title":"Radiology"},{"issue":"9","key":"10.1016\/j.ejmp.2022.01.007_b0075","doi-asserted-by":"crossref","first-page":"3904","DOI":"10.1007\/s00330-017-4752-9","article-title":"Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT","volume":"27","author":"Pelgrim","year":"2017","journal-title":"Eur Radiol."},{"key":"10.1016\/j.ejmp.2022.01.007_b0080","unstructured":"Report 24. Journal of the International Commission on Radiation Units and Measurements. 2016;os13:NP-NP."},{"issue":"3","key":"10.1016\/j.ejmp.2022.01.007_b0085","doi-asserted-by":"crossref","first-page":"1406","DOI":"10.1118\/1.3551990","article-title":"Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe","volume":"38","author":"McKenney","year":"2011","journal-title":"Med Phys."},{"issue":"2","key":"10.1016\/j.ejmp.2022.01.007_b0090","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1118\/1.596709","article-title":"Semiempirical model for generating tungsten target x-ray spectra","volume":"18","author":"Tucker","year":"1991","journal-title":"Med Phys."},{"issue":"19","key":"10.1016\/j.ejmp.2022.01.007_b0095","doi-asserted-by":"crossref","first-page":"N433","DOI":"10.1088\/0031-9155\/54\/19\/N01","article-title":"SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes","volume":"54","author":"Poludniowski","year":"2009","journal-title":"Phys Med Biol"},{"issue":"947","key":"10.1016\/j.ejmp.2022.01.007_b0100","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1259\/bjr\/66519303","article-title":"Conversion factor for CT dosimetry to assess patient dose using a 256-slice CT scanner","volume":"79","author":"Mori","year":"2006","journal-title":"Br J Radiol."},{"issue":"6","key":"10.1016\/j.ejmp.2022.01.007_b0105","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/j.jcct.2016.10.002","article-title":"SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the society of Cardiovascular Computed Tomography Guidelines Committee: Endorsed by the North American Society for Cardiovascular Imaging (NASCI)","volume":"10","author":"Abbara","year":"2016","journal-title":"J Cardiovasc Comput Tomogr."},{"issue":"1-4","key":"10.1016\/j.ejmp.2022.01.007_b0110","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1093\/rpd\/ncv527","article-title":"Implications of Patient Centring on Organ Dose in Computed Tomography","volume":"169","author":"Kataria","year":"2016","journal-title":"Radiat Prot Dosimetry."},{"issue":"3","key":"10.1016\/j.ejmp.2022.01.007_b0115","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications","volume":"276","author":"McCollough","year":"2015","journal-title":"Radiology"},{"issue":"5_supplement","key":"10.1016\/j.ejmp.2022.01.007_b0120","doi-asserted-by":"crossref","first-page":"S9","DOI":"10.2214\/AJR.12.9121","article-title":"Dual-energy CT-based monochromatic imaging","volume":"199","author":"Yu","year":"2012","journal-title":"AJR Am J Roentgenol."},{"issue":"1","key":"10.1016\/j.ejmp.2022.01.007_b0125","first-page":"20200006","article-title":"Decreasing the radiation dose for contrast-enhanced abdominal spectral CT with a half contrast dose: a matched-pair comparison with a 120 kVp protocol","volume":"2","author":"Sakabe","year":"2020","journal-title":"BJR Open."}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179722014089?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179722014089?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T03:47:52Z","timestamp":1761104872000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179722014089"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3]]},"references-count":25,"alternative-id":["S1120179722014089"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2022.01.007","relation":{},"ISSN":["1120-1797"],"issn-type":[{"type":"print","value":"1120-1797"}],"subject":[],"published":{"date-parts":[[2022,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of the effects of varying tube voltage and iodinated concentration on increasing the iodinated radiation dose in computed tomography","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2022.01.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}