{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T22:19:55Z","timestamp":1761171595832,"version":"build-2065373602"},"reference-count":21,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:00:00Z","timestamp":1690848000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:00:00Z","timestamp":1690848000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T00:00:00Z","timestamp":1722988800000},"content-version":"am","delay-in-days":372,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2023,8]]},"DOI":"10.1016\/j.ejmp.2023.102646","type":"journal-article","created":{"date-parts":[[2023,8,7]],"date-time":"2023-08-07T09:45:56Z","timestamp":1691401556000},"page":"102646","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Improvement of diagnostic performance of hyperacute ischemic stroke in head CT using an image-based noise reduction technique with non-black-boxed process"],"prefix":"10.1016","volume":"112","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9774-0966","authenticated-orcid":false,"given":"Tetsuya","family":"Hirairi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katsuhiro","family":"Ichikawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5799-0944","authenticated-orcid":false,"given":"Atsushi","family":"Urikura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Kawashima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takasumi","family":"Tabata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tamaki","family":"Matsunami","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.ejmp.2023.102646_b0005","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1097\/RCT.0b013e3182a17629","article-title":"Preliminary results: prospective clinical study to assess image-based iterative reconstruction for abdominal computed tomography acquired at 2 radiation dose levels","volume":"38","author":"Pourjabbar","year":"2014","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.ejmp.2023.102646_b0010","doi-asserted-by":"crossref","unstructured":"Watanabe S, Ichikawa K, Kawashima H, Kono Y, Kosaka H, Yamada K, et al. Image quality comparison of a nonlinear image-based noise reduction technique with a hybrid-type iterative reconstruction for pediatric computed tomography. Phys Med. 2020; 76:100-108. https:\/\/doi.org\/286 10.1016\/j.ejmp.2020.06.015.","DOI":"10.1016\/j.ejmp.2020.06.015"},{"issue":"12","key":"10.1016\/j.ejmp.2023.102646_b0015","doi-asserted-by":"crossref","first-page":"2536","DOI":"10.1109\/TMI.2017.2708987","article-title":"Generative adversarial networks for noise reduction in low-dose CT","volume":"36","author":"Wolterink","year":"2017","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.ejmp.2023.102646_b0020","doi-asserted-by":"crossref","first-page":"41839","DOI":"10.1109\/ACCESS.2018.2858196","article-title":"Structurally-sensitive multi-scale deep neural network for low-dose CT denoising","volume":"6","author":"You","year":"2018","journal-title":"IEEE Access"},{"key":"10.1016\/j.ejmp.2023.102646_b0025","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1007\/s00234-015-1631-4","article-title":"Comparison of iterative model, hybrid iterative, and 1 filtered back projection reconstruction techniques in low-dose brain CT: impact of thin slice imaging","volume":"58","author":"Nakaura","year":"2016","journal-title":"Neuroradiology"},{"key":"10.1016\/j.ejmp.2023.102646_b0030","doi-asserted-by":"crossref","unstructured":"Sekino H, Ishii S, Kuroiwa D, Fujimaki H, Sugawara S, Suenaga H, et al. Usefulness of model-based iterative reconstruction in brain CT as compared with hybrid iterative reconstruction. J Comput Assist Tomogr. 2021; 01;45(4):600-605. https:\/\/doi,org\/10.1097\/RCT.0000000000001171.","DOI":"10.1097\/RCT.0000000000001171"},{"issue":"2","key":"10.1016\/j.ejmp.2023.102646_b0035","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1148\/radiol.2015132766","article-title":"Iterative CT reconstruction techniques","volume":"276","author":"Geyer","year":"2015","journal-title":"Radiology"},{"issue":"12","key":"10.1016\/j.ejmp.2023.102646_b0040","doi-asserted-by":"crossref","first-page":"1663","DOI":"10.1007\/s00247-016-3676-x","article-title":"Effect of the forward-projected model-based iterative reconstruction solution algorithm on image quality and radiation dose in pediatric cardiac computed tomography","volume":"46","author":"Nishiyama","year":"2016","journal-title":"Pediatr Radiol"},{"issue":"4","key":"10.1016\/j.ejmp.2023.102646_b0045","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1148\/rg.344135128","article-title":"Methods for clinical evaluation of noise reduction techniques in abdominopelvic CT","volume":"34","author":"Ehman","year":"2014","journal-title":"Radiographics"},{"issue":"8","key":"10.1016\/j.ejmp.2023.102646_b0050","doi-asserted-by":"crossref","first-page":"5498","DOI":"10.1007\/s00330-020-07668-x","article-title":"Deep learning\u2013based reconstruction may improve non-contrast cerebral CT imaging compared to other current reconstruction algorithms","volume":"31","author":"Oostveen","year":"2021","journal-title":"Eur Radiol"},{"key":"10.1016\/j.ejmp.2023.102646_b0055","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.3390\/diagnostics12051287","article-title":"Deep learning-based reconstruction vs. iterative reconstruction for quality of low-dose head-and-neck CT angiography with different tube-voltage protocols in emergency-department patients","volume":"12","author":"Lenfant","year":"2022","journal-title":"Diagnostics"},{"key":"10.1016\/j.ejmp.2023.102646_b0060","doi-asserted-by":"crossref","first-page":"102558","DOI":"10.1016\/j.ejmp.2023.102558","article-title":"Brain image quality according to beam collimation width and image reconstruction algorithm: a phantom study","volume":"108","author":"Greffier","year":"2023","journal-title":"Phys Med"},{"issue":"5","key":"10.1016\/j.ejmp.2023.102646_b0065","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.jcct.2020.01.002","article-title":"Validation of deep-learning image reconstruction for coronary computed tomography angiography: Impact on noise, image quality and diagnostic accuracy","volume":"14","author":"Benz","year":"2020","journal-title":"J Cardiovasc Comput Tomogra"},{"issue":"7","key":"10.1016\/j.ejmp.2023.102646_b0070","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1002\/acm2.13318","article-title":"Image quality improvement with deep learning-based reconstruction on abdominal ultrahigh-resolution CT: a phantom study","volume":"22","author":"Shirasaka","year":"2021","journal-title":"J Appl Clin Med Phys"},{"issue":"2","key":"10.1016\/j.ejmp.2023.102646_b0075","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1007\/s10140-021-02012-2","article-title":"Deep learning versus iterative image reconstruction algorithm for head CT in trauma","volume":"29","author":"Alagic","year":"2022","journal-title":"Emerg Radiol"},{"key":"10.1016\/j.ejmp.2023.102646_b0080","doi-asserted-by":"crossref","DOI":"10.1016\/j.compbiomed.2019.103353","article-title":"A three-dimensional cross-directional bilateral filter for edge-preserving noise reduction of low-dose computed tomography images","volume":"111","author":"Ichikawa","year":"2019","journal-title":"Comput Biol Med"},{"key":"10.1016\/j.ejmp.2023.102646_b0085","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1109\/ICCV.1998.710815","article-title":"Bilateral filtering for gray and color images","author":"Tomasi","year":"1998","journal-title":"IEEE Proc Int Conf Comput Vis"},{"key":"10.1016\/j.ejmp.2023.102646_b0090","unstructured":"The Japan Stroke Society: Japanese guideline for the management of stroke 2015, Supplement 2019. 2019 (in Japanese)."},{"issue":"9","key":"10.1016\/j.ejmp.2023.102646_b0095","doi-asserted-by":"crossref","first-page":"3609","DOI":"10.1007\/s00330-017-4733-z","article-title":"Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children","volume":"27","author":"Kim","year":"2017","journal-title":"Eur Radiol"},{"issue":"3","key":"10.1016\/j.ejmp.2023.102646_b0100","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1038\/bmt.2012.244","article-title":"Investigation of the freely available easy-to-use software \u2018EZR\u2019 for medical statistics","volume":"48","author":"Kanda","year":"2013","journal-title":"Bone Marrow Transplant"},{"issue":"1054","key":"10.1016\/j.ejmp.2023.102646_b0105","doi-asserted-by":"crossref","first-page":"20150463","DOI":"10.1259\/bjr.20150463","article-title":"The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique","volume":"88","author":"Kwon","year":"2015","journal-title":"Br J Radiol"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179723001230?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179723001230?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T03:57:55Z","timestamp":1761105475000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179723001230"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8]]},"references-count":21,"alternative-id":["S1120179723001230"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2023.102646","relation":{},"ISSN":["1120-1797"],"issn-type":[{"type":"print","value":"1120-1797"}],"subject":[],"published":{"date-parts":[[2023,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Improvement of diagnostic performance of hyperacute ischemic stroke in head CT using an image-based noise reduction technique with non-black-boxed process","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2023.102646","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"102646"}}