{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T22:06:19Z","timestamp":1769551579266,"version":"3.49.0"},"reference-count":18,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001637","name":"Trinity College Dublin","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001637","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100020552","name":"Oman Ministry of Higher Education","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100020552","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2024,8]]},"DOI":"10.1016\/j.ejmp.2024.103430","type":"journal-article","created":{"date-parts":[[2024,7,23]],"date-time":"2024-07-23T16:09:59Z","timestamp":1721750999000},"page":"103430","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Blood Micro-sampling: An alternative blood collection method for radioiodine therapy dosimetry"],"prefix":"10.1016","volume":"124","author":[{"given":"Amna","family":"Al Jabri","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jennie","family":"Cooke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8185-968X","authenticated-orcid":false,"given":"Se\u00e1n","family":"Cournane","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marie-Louise","family":"Healy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejmp.2024.103430_b0005","unstructured":"Directive C. Council Directive 2013\/59\/EURATOM of 5 December 2013 Laying down Basic Safety Standards for Protection against the Dangers Arising from Exposure to Ionising Radiation, and Repealing Directives 89\/618\/Euratom, 90\/641\/Euratom, 96\/29\/Euratom, 97\/43\/Euratom and 2003\/122\/Euratom. 2013. Official Journal of the European Union L. 2013;13:1-73."},{"key":"10.1016\/j.ejmp.2024.103430_b0010","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1007\/s00259-008-0761-x","article-title":"EANM Dosimetry Committee series on standard operational procedures for pre-therapeutic dosimetry I: blood and bone marrow dosimetry in differentiated thyroid cancer therapy","volume":"35","author":"Lassmann","year":"2008","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1016\/j.ejmp.2024.103430_b0015","first-page":"899","article-title":"Blood and bone marrow dosimetry in radioiodine therapy of thyroid cancer","volume":"46","author":"Sgouros","year":"2005","journal-title":"J Nucl Med"},{"key":"10.1016\/j.ejmp.2024.103430_b0020","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1088\/1361-6498\/ab9507","article-title":"Radiation exposure to allied health personnel handling blood specimens from patients receiving radioactive iodine-131 and recombinant human TSH (Thyrogen\u00ae) stimulation","volume":"41","author":"Sarah","year":"2021","journal-title":"J Radiol Prot"},{"key":"10.1016\/j.ejmp.2024.103430_b0025","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1080\/17434440.2023.2170783","article-title":"Minimally invasive capillary blood sampling methods","volume":"20","author":"Hoffman","year":"2023","journal-title":"Expert Rev Med Devices"},{"key":"10.1016\/j.ejmp.2024.103430_b0030","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1039\/C6JA00394J","article-title":"Iron isotopic analysis of finger-prick and venous blood by multi-collector inductively coupled plasma-mass spectrometry after volumetric absorptive microsampling","volume":"32","author":"Anoshkina","year":"2017","journal-title":"J Anal At Spectrom"},{"key":"10.1016\/j.ejmp.2024.103430_b0035","article-title":"Evaluation of Glutathione S-Transferase Activity in Venous and Finger-Prick Blood in Healthy Smoking and Non-Smoking Men in Kuwait. Jordan","volume":"12","author":"Almutairi","year":"2019","journal-title":"J Pharm Sci"},{"key":"10.1016\/j.ejmp.2024.103430_b0040","doi-asserted-by":"crossref","first-page":"e43702","DOI":"10.1371\/journal.pone.0043702","article-title":"Comparison of venous and capillary differential leukocyte counts using a standard hematology analyzer and a novel microfluidic impedance cytometer","volume":"7","author":"Hollis","year":"2012","journal-title":"PLoS One"},{"key":"10.1016\/j.ejmp.2024.103430_b0045","doi-asserted-by":"crossref","first-page":"65","DOI":"10.4103\/0974-2727.176238","article-title":"Comparison of complete blood count parameters between venous and capillary blood in oncology patients","volume":"8","author":"Chavan","year":"2016","journal-title":"Journal of laboratory physicians"},{"key":"10.1016\/j.ejmp.2024.103430_b0050","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1111\/j.1365-2125.2010.03668.x","article-title":"Can finger-prick sampling replace venous sampling to determine the pharmacokinetic profile of oral paracetamol?","volume":"70","author":"Mohammed","year":"2010","journal-title":"Br J Clin Pharmacol"},{"key":"10.1016\/j.ejmp.2024.103430_b0055","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1080\/312704000905","article-title":"Correlation of capillary and venous blood glucometry with laboratory determination","volume":"8","author":"Kumar","year":"2004","journal-title":"Prehosp Emerg Care"},{"key":"10.1016\/j.ejmp.2024.103430_b0060","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1007\/s00228-010-0804-7","article-title":"Comparison of plasma, venous and capillary blood levels of piperaquine in patients with uncomplicated falciparum malaria","volume":"66","author":"Ashley","year":"2010","journal-title":"Eur J Clin Pharmacol"},{"key":"10.1016\/j.ejmp.2024.103430_b0065","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1002\/dta.1760","article-title":"Do capillary dried blood spot concentrations of gamma-hydroxybutyric acid mirror those in venous blood? A comparative study","volume":"7","author":"Sadones","year":"2015","journal-title":"Drug Test Anal"},{"key":"10.1016\/j.ejmp.2024.103430_b0070","first-page":"2119","article-title":"Are capillary DBS applicable for therapeutic drug monitoring of common antipsychotics?","volume":"7","author":"Patteet","year":"2015","journal-title":"A proof of concept Bioanalysis"},{"key":"10.1016\/j.ejmp.2024.103430_b0075","series-title":"Dosimetric concepts and calibration of instruments","first-page":"1","author":"Dietze","year":"2001"},{"key":"10.1016\/j.ejmp.2024.103430_b0080","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1159\/000490384","article-title":"2018 European Thyroid Association guideline for the management of Graves\u2019 hyperthyroidism","volume":"7","author":"Kahaly","year":"2018","journal-title":"European thyroid journal"},{"key":"10.1016\/j.ejmp.2024.103430_b0085","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1136\/emj.2003.011619","article-title":"Capillary versus venous bedside blood glucose estimations","volume":"22","author":"Boyd","year":"2005","journal-title":"Emerg Med J"},{"key":"10.1016\/j.ejmp.2024.103430_b0090","doi-asserted-by":"crossref","first-page":"1875","DOI":"10.1021\/acssensors.1c00139","article-title":"Touch-based fingertip blood-free reliable glucose monitoring: Personalized data processing for predicting blood glucose concentrations","volume":"6","author":"Sempionatto","year":"2021","journal-title":"ACS Sensors"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179724002254?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179724002254?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T17:59:39Z","timestamp":1762365579000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179724002254"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8]]},"references-count":18,"alternative-id":["S1120179724002254"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2024.103430","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2024,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Blood Micro-sampling: An alternative blood collection method for radioiodine therapy dosimetry","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2024.103430","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"103430"}}