{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T06:02:08Z","timestamp":1785391328375,"version":"3.55.0"},"reference-count":44,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2024,11]]},"DOI":"10.1016\/j.ejmp.2024.104829","type":"journal-article","created":{"date-parts":[[2024,10,4]],"date-time":"2024-10-04T20:16:53Z","timestamp":1728073013000},"page":"104829","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Sectored single-energy volumetric-modulated proton arc therapy (VPAT): A preliminary multi-disease-site concept study"],"prefix":"10.1016","volume":"127","author":[{"given":"Arezoo","family":"Modiri","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sina","family":"Mossahebi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amit","family":"Sawant","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shifeng","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Baoshe","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8805-0250","authenticated-orcid":false,"given":"Byongyong","family":"Yi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.ejmp.2024.104829_b0005","doi-asserted-by":"crossref","first-page":"e16","DOI":"10.1016\/S1470-2045(19)30802-2","article-title":"Intelligence outcomes after proton versus photon therapy","volume":"21","author":"Das","year":"2020","journal-title":"Lancet Oncol"},{"issue":"1107","key":"10.1016\/j.ejmp.2024.104829_b0010","doi-asserted-by":"crossref","first-page":"20190378","DOI":"10.1259\/bjr.20190378","article-title":"Proton therapy for locally advanced non-small cell lung cancer","volume":"93","author":"Gjyshi","year":"2020","journal-title":"Br J Radiol"},{"key":"10.1016\/j.ejmp.2024.104829_b0015","doi-asserted-by":"crossref","DOI":"10.1177\/1753466618783878","article-title":"Advances in proton therapy in lung cancer","volume":"12","author":"Vyfhuis","year":"2018","journal-title":"Ther Adv Respir Dis"},{"issue":"3","key":"10.1016\/j.ejmp.2024.104829_b0020","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.semradonc.2018.02.010","article-title":"Relative biological effectiveness uncertainties and implications for beam arrangements and dose constraints in proton therapy","volume":"28","author":"Paganetti","year":"2018","journal-title":"Semin Radiat Oncol"},{"issue":"1107","key":"10.1016\/j.ejmp.2024.104829_b0025","doi-asserted-by":"crossref","first-page":"20190469","DOI":"10.1259\/bjr.20190469","article-title":"Is there a role for arcing techniques in proton therapy?","volume":"93","author":"Carabe-Fernandez","year":"2020","journal-title":"Br J Radiol"},{"issue":"S1","key":"10.1016\/j.ejmp.2024.104829_b0030","doi-asserted-by":"crossref","first-page":"S43","DOI":"10.1016\/0167-8140(96)80599-8","article-title":"Conformal proton tomotherapy using distal-edge tracking","volume":"37","author":"Deasy","year":"1995","journal-title":"Radiother Oncol"},{"issue":"4","key":"10.1016\/j.ejmp.2024.104829_b0035","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1016\/S0360-3016(97)00059-X","article-title":"Phantom assessment of lung dose from proton arc therapy","volume":"38","author":"Sandison","year":"1997","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"3","key":"10.1016\/j.ejmp.2024.104829_b0040","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1080\/0284186X.2017.1358463","article-title":"Have we reached proton beam therapy dosimetric limitations? - A novel robust, delivery-efficient and continuous spot-scanning proton arc (SPArc) therapy is to improve the dosimetric outcome in treating prostate cancer","volume":"57","author":"Ding","year":"2018","journal-title":"Acta Oncol"},{"issue":"5","key":"10.1016\/j.ejmp.2024.104829_b0045","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/j.ijrobp.2016.08.049","article-title":"Spot-Scanning proton Arc (SPArc) therapy: the first robust and delivery-efficient spot-scanning proton arc therapy","volume":"96","author":"Ding","year":"2016","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104829_b0050","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/j.ijrobp.2013.04.048","article-title":"Proton arc reduces range uncertainty effects and improves conformality compared with photon volumetric modulated arc therapy in stereotactic body radiation therapy for non-small cell lung cancer","volume":"87","author":"Seco","year":"2013","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2024.104829_b0055","doi-asserted-by":"crossref","DOI":"10.1002\/mp.14083","article-title":"A novel energy layer optimization framework for spot-scanning proton arc therapy","author":"Gu","year":"2020","journal-title":"Med Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104829_b0060","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s13014-020-1476-9","article-title":"Improve the dosimetric outcome in bilateral head and neck cancer (HNC) treatment using spot-scanning proton arc (SPArc) therapy: a feasibility study","volume":"15","author":"Liu","year":"2020","journal-title":"Radiat Oncol"},{"issue":"6","key":"10.1016\/j.ejmp.2024.104829_b0065","doi-asserted-by":"crossref","first-page":"1246","DOI":"10.1118\/1.599002","article-title":"Intensity modulated radiotherapy with charged particle beams: studies of inverse treatment planning for rotation therapy","volume":"27","author":"Oelfke","year":"2000","journal-title":"Med Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104829_b0070","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1186\/s13014-016-0717-4","article-title":"A treatment planning study of proton arc therapy for para-aortic lymph node tumors: dosimetric evaluation of conventional proton therapy, proton arc therapy, and intensity modulated radiotherapy","volume":"11","author":"Rah","year":"2016","journal-title":"Radiat Oncol (London, England)"},{"issue":"9\u201310","key":"10.1016\/j.ejmp.2024.104829_b0075","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.3109\/0284186X.2016.1170199","article-title":"Dosimetric feasibility of single-energy proton modulated arc therapy for treatment of chordoma at the skull base","volume":"55","author":"Blanco Kiely","year":"2016","journal-title":"Acta Oncol"},{"issue":"3","key":"10.1016\/j.ejmp.2024.104829_b0080","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1002\/mp.16098","article-title":"Spot scanning proton arc therapy reduces toxicity in oropharyngeal cancer patients","volume":"50","author":"de Jong","year":"2023","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2024.104829_b0085","unstructured":"Langner, U.W., Eley, J.G., Guerrero, M., Langen, K., Mossahebi, S., Zhu, M., D'Souza, W.D. and Yi, B. A method to deliver energy modulated planar proton arc therapy (EMPPAT). 20SemanticScholar."},{"issue":"2","key":"10.1016\/j.ejmp.2024.104829_b0090","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1118\/1.3049787","article-title":"Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy","volume":"36","author":"Sengbusch","year":"2009","journal-title":"Med Phys"},{"issue":"5","key":"10.1016\/j.ejmp.2024.104829_b0095","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/abe02b","article-title":"A static beam delivery device for fast scanning proton arc-therapy","volume":"66","author":"Nesteruk","year":"2021","journal-title":"Phys Med Biol"},{"issue":"9","key":"10.1016\/j.ejmp.2024.104829_b0100","doi-asserted-by":"crossref","first-page":"5723","DOI":"10.1002\/mp.16617","article-title":"Partitioning of discrete proton arcs into interlaced subplans can bring proton arc advances to existing proton facilities","volume":"50","author":"Engwall","year":"2023","journal-title":"Med Phys"},{"issue":"20","key":"10.1016\/j.ejmp.2024.104829_b0105","doi-asserted-by":"crossref","first-page":"6073","DOI":"10.1088\/0031-9155\/52\/20\/001","article-title":"Comparison of intensity modulated x-ray therapy and intensity modulated proton therapy for selective subvolume boosting: a phantom study","volume":"52","author":"Flynn","year":"2007","journal-title":"Phys Med Biol"},{"issue":"21","key":"10.1016\/j.ejmp.2024.104829_b0110","doi-asserted-by":"crossref","first-page":"N565","DOI":"10.1088\/0031-9155\/61\/21\/N565","article-title":"Range optimization for mono- and bi-energetic proton modulated arc therapy with pencil beam scanning","volume":"61","author":"Sanchez-Parcerisa","year":"2016","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2024.104829_b0115","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.radonc.2019.04.032","article-title":"The first prototype of spot-scanning proton arc treatment delivery","volume":"137","author":"Li","year":"2019","journal-title":"Radiother Oncol"},{"issue":"16","key":"10.1016\/j.ejmp.2024.104829_b0120","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ab9455","article-title":"Proton monoenergetic arc therapy (PMAT) to enhance LETd within the target","volume":"65","author":"Bertolet","year":"2020","journal-title":"Phys Med Biol"},{"issue":"6","key":"10.1016\/j.ejmp.2024.104829_b0125","first-page":"E503","article-title":"High-efficiency volumetric-modulated proton arc therapy (HEV-PAT): a multi-disease-site concept study (Abstract)","volume":"49","author":"Modiri","year":"2022","journal-title":"Med Phys"},{"issue":"2","key":"10.1016\/j.ejmp.2024.104829_b0130","doi-asserted-by":"crossref","first-page":"31","DOI":"10.14338\/IJPT-22-00013.1","article-title":"Proton arc therapy vs interstitial HDR brachytherapy in gynecologic cancer with parametrial\/pelvic side wall extension","volume":"9","author":"Yi","year":"2022","journal-title":"Int J Part Ther"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104829_b0135","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/0360-3016(95)00113-D","article-title":"Which is the most suitable number of photon beam portals in coplanar radiation therapy?","volume":"33","author":"S\u00f6derstr\u00f6m","year":"1995","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2024.104829_b0140","unstructured":"Internation Electrotechnical Commission, IEC 61217 Radiotherapy eqipment -Coordinate, movements and scales, 2011, IEC; https:\/\/webstore.iec.ch\/preview\/info_iec61217%7Bed2.0%7Db.pdf. [Accessed on Apr 3rd 2024]."},{"key":"10.1016\/j.ejmp.2024.104829_b0145","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ad29b7","article-title":"Optimizing the traversal time for gantry trajectories for proton arc therapy treatment plans","author":"Wase","year":"2024","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2024.104829_b0150","article-title":"Development of a standalone delivery sequence model for proton arc therapy","author":"Liu","year":"2023","journal-title":"Med Phys"},{"issue":"6","key":"10.1016\/j.ejmp.2024.104829_b0155","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ac55a6","article-title":"Fast robust optimization of proton PBS arc therapy plans using early energy layer selection and spot assignment","volume":"67","author":"Engwall","year":"2022","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2024.104829_b0160","doi-asserted-by":"crossref","DOI":"10.1016\/j.radonc.2023.109670","article-title":"Proton arc therapy increases the benefit of proton therapy for oropharyngeal cancer patients in the model based clinic","volume":"184","author":"de Jong","year":"2023","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2024.104829_b0165","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.ejmp.2018.12.011","article-title":"Impact of spot size variations on dose in scanned proton beam therapy","volume":"57","author":"Kraan","year":"2019","journal-title":"Phys Med"},{"issue":"3","key":"10.1016\/j.ejmp.2024.104829_b0170","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1118\/1.4908208","article-title":"Impact of range shifter material on proton pencil beam spot characteristics","volume":"42","author":"Shen","year":"2015","journal-title":"Med Phys"},{"issue":"8","key":"10.1016\/j.ejmp.2024.104829_b0175","doi-asserted-by":"crossref","first-page":"3496","DOI":"10.1002\/mp.13972","article-title":"Commissioning and beam characterization of the first gantry-mounted accelerator pencil beam scanning proton system","volume":"47","author":"Kang","year":"2020","journal-title":"Med Phys"},{"issue":"2","key":"10.1016\/j.ejmp.2024.104829_b0180","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1002\/acm2.12803","article-title":"Sensitivity analysis of Monte Carlo model of a gantry-mounted passively scattered proton system","volume":"21","author":"Baradaran-Ghahfarokhi","year":"2020","journal-title":"J Appl Clin Med Phys"},{"issue":"2","key":"10.1016\/j.ejmp.2024.104829_b0185","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1120\/jacmp.v17i2.5868","article-title":"Commissioning and initial experience with the first clinical gantry-mounted proton therapy system","volume":"17","author":"Zhao","year":"2016","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104829_b0190","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1002\/acm2.12225","article-title":"Commissioning of the world's first compact pencil-beam scanning proton therapy system","volume":"19","author":"Pidikiti","year":"2018","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104829_b0195","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.meddos.2023.10.011","article-title":"Dosimetric evaluation of dose shaping by adaptive aperture and its impact on plan quality","volume":"49","author":"Silvus","year":"2024","journal-title":"Med Dosim"},{"issue":"3","key":"10.1016\/j.ejmp.2024.104829_b0200","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1118\/1.4941957","article-title":"A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams","volume":"43","author":"Charlwood","year":"2016","journal-title":"Med Phys"},{"issue":"9","key":"10.1016\/j.ejmp.2024.104829_b0205","doi-asserted-by":"crossref","first-page":"e13997","DOI":"10.1002\/acm2.13997","article-title":"Effect of the initial energy layer and spot placement parameters on IMPT delivery efficiency and plan quality","volume":"24","author":"Zhu","year":"2023","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2024.104829_b0210","doi-asserted-by":"crossref","unstructured":"Yi, B., Mossahebi, S., Jatczak, J., Mundis, M., Houser, T., Alicia, D., Han, D., Gonzalez, R., Olis, S. and Zakhary, M., Optimal minimum MU for intensity-modulated proton therapy with pencil-beam scanning proton beams. J Appl Clin Med Phys, 2024. e14435(https:\/\/doi.org\/10.1002\/acm2.14435).","DOI":"10.1002\/acm2.14435"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104829_b0215","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1118\/1.597522","article-title":"The 200-MeV proton therapy project at the Paul Scherrer Institute: conceptual design and practical realization","volume":"22","author":"Pedroni","year":"1995","journal-title":"Med Phys"},{"issue":"8","key":"10.1016\/j.ejmp.2024.104829_b0220","doi-asserted-by":"crossref","first-page":"e14091","DOI":"10.1002\/acm2.14091","article-title":"FLASH instead of proton arc therapy is a more promising advancement for the next generation proton radiotherapy","volume":"24","author":"Kang","year":"2023","journal-title":"J Appl Clin Med Phys"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S112017972401086X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S112017972401086X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T19:58:50Z","timestamp":1731009530000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S112017972401086X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":44,"alternative-id":["S112017972401086X"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2024.104829","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2024,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Sectored single-energy volumetric-modulated proton arc therapy (VPAT): A preliminary multi-disease-site concept study","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2024.104829","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"104829"}}