{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T13:35:21Z","timestamp":1790948121087,"version":"4.1.0"},"reference-count":24,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"am","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["21K07722"],"award-info":[{"award-number":["21K07722"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["20K16819"],"award-info":[{"award-number":["20K16819"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["24K18790"],"award-info":[{"award-number":["24K18790"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["22K07792"],"award-info":[{"award-number":["22K07792"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2024,11]]},"DOI":"10.1016\/j.ejmp.2024.104852","type":"journal-article","created":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T06:16:41Z","timestamp":1730441801000},"page":"104852","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["Selection criteria for circular collimator- vs. Multileaf collimator-based plans in robotic stereotactic radiotherapy for brain metastases and benign intracranial disease: Impact of target size, shape complexity, and proximity to at-risk organs"],"prefix":"10.1016","volume":"127","author":[{"given":"Takeshi","family":"Takizawa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3488-3871","authenticated-orcid":false,"given":"Satoshi","family":"Tanabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9023-880X","authenticated-orcid":false,"given":"Hisashi","family":"Nakano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoru","family":"Utsunomiya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuya","family":"Maruyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Motoki","family":"Kaidu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Ishikawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiyoshi","family":"Onda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"21","key":"10.1016\/j.ejmp.2024.104852_b0005","doi-asserted-by":"crossref","first-page":"2483","DOI":"10.1001\/jama.295.21.2483","article-title":"Stereotactic radiosurgery plus whole-brain radiation therapy vs stereotactic radiosurgery alone for treatment of brain metastases: a randomized controlled trial","volume":"295","author":"Aoyama","year":"2006","journal-title":"JAMA"},{"issue":"3","key":"10.1016\/j.ejmp.2024.104852_b0010","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.radonc.2011.01.011","article-title":"Dose-effect relation in stereotactic radiotherapy for brain metastases. A systematic review","volume":"98","author":"Wiggenraad","year":"2011","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2024.104852_b0015","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1007\/s11060-009-9831-6","article-title":"Stereotactic radiosurgery of benign intracranial tumors","volume":"92","author":"Pollock","year":"2009","journal-title":"J Neurooncol"},{"issue":"2","key":"10.1016\/j.ejmp.2024.104852_b0020","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/s12194-022-00655-5","article-title":"The impact of target positioning error and tumor size on radiobiological parameters in robotic stereotactic radiosurgery for metastatic brain tumors","volume":"15","author":"Takizawa","year":"2022","journal-title":"Radiol Phys Technol"},{"key":"10.1016\/j.ejmp.2024.104852_b0025","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.ejmp.2018.11.012","article-title":"CyberKnife MLC-based treatment planning for abdominal and pelvic SBRT: analysis of multiple dosimetric parameters, overall scoring index and clinical scoring","volume":"56","author":"Masi","year":"2018","journal-title":"Phys Med"},{"issue":"5","key":"10.1016\/j.ejmp.2024.104852_b0030","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1120\/jacmp.v16i5.5502","article-title":"Investigating the clinical advantages of a robotic linac equipped with a multileaf collimator in the treatment of brain and prostate cancer patients","volume":"16","author":"McGuinness","year":"2015","journal-title":"J Appl Clin Med Phys"},{"issue":"5","key":"10.1016\/j.ejmp.2024.104852_b0035","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1093\/jrr\/rrw130","article-title":"Comparison of multileaf collimator and conventional circular collimator systems in Cyberknife stereotactic radiotherapy","volume":"58","author":"Murai","year":"2017","journal-title":"J Radiat Res"},{"issue":"5","key":"10.1016\/j.ejmp.2024.104852_b0040","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1120\/jacmp.v17i5.6260","article-title":"Dosimetric comparison between cone\/Iris-based and InCise MLC-based CyberKnife plans for single and multiple brain metastases","volume":"17","author":"Jang","year":"2016","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104852_b0045","doi-asserted-by":"crossref","first-page":"9953","DOI":"10.1038\/s41598-019-46133-8","article-title":"Plan quality and secondary cancer risk assessment in patients with benign intracranial lesions after radiosurgery using the CyberKnife M6 robotic radiosurgery system","volume":"9","author":"Lan","year":"2019","journal-title":"Sci Rep"},{"key":"10.1016\/j.ejmp.2024.104852_b0050","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.ejmp.2020.02.009","article-title":"Performance assessment of a new optimization system for robotic SBRT MLC-based plans","volume":"71","author":"Calusi","year":"2020","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2024.104852_b0055","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1016\/j.ejmp.2019.07.020","article-title":"Novel inverse planning optimization algorithm for robotic radiosurgery: first clinical implementation and dosimetric evaluation","volume":"64","author":"Zeverino","year":"2019","journal-title":"Phys Med"},{"issue":"5","key":"10.1016\/j.ejmp.2024.104852_b0060","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1002\/acm2.12851","article-title":"Clinical impact of the VOLO optimizer on treatment plan quality and clinical treatment efficiency for CyberKnife","volume":"21","author":"Sch\u00fcler","year":"2020","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104852_b0065","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.ijrobp.2021.09.027","article-title":"A story of hypofractionation and the table on the wall","volume":"112","author":"Timmerman","year":"2022","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104852_b0070","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1186\/s13014-021-01766-w","article-title":"Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics","volume":"16","author":"Chea","year":"2021","journal-title":"Radiat Oncol"},{"issue":"suppl","key":"10.1016\/j.ejmp.2024.104852_b0075","first-page":"194","article-title":"A simple dose gradient measurement tool to complement the conformity index","volume":"105","author":"Paddick","year":"2006","journal-title":"J Neurol Surg"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104852_b0080","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.ijrobp.2020.08.013","article-title":"Single- and multifraction stereotactic radiosurgery dose\/volume tolerances of the brain","volume":"110","author":"Milano","year":"2021","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"4","key":"10.1016\/j.ejmp.2024.104852_b0085","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1093\/jrr\/rrt006","article-title":"Three-fraction CyberKnife radiotherapy for brain metastases in critical areas: referring to the risk evaluating radiation necrosis and the surrounding brain volumes circumscribed with a single dose equivalence of 14 Gy (V14)","volume":"54","author":"Inoue","year":"2013","journal-title":"J Radiat Res"},{"key":"10.1016\/j.ejmp.2024.104852_b0090","doi-asserted-by":"crossref","first-page":"32","DOI":"10.4103\/sni.sni_303_18","article-title":"Updated risk models demonstrate low risk of symptomatic radionecrosis following stereotactic radiosurgery for brain metastases","volume":"10","author":"Peng","year":"2019","journal-title":"Surg Neurol Int"},{"issue":"Suppl","key":"10.1016\/j.ejmp.2024.104852_b0095","doi-asserted-by":"crossref","first-page":"189","DOI":"10.3171\/2012.7.GKS12962","article-title":"Dose-volume effects on brainstem dose tolerance in radiosurgery","volume":"117","author":"Xue","year":"2012","journal-title":"J Neurosurg"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104852_b0100","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.ijrobp.2019.09.038","article-title":"Spinal cord dose tolerance to stereotactic body radiation therapy","volume":"110","author":"Sahgal","year":"2021","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104852_b0105","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.ijrobp.2018.01.053","article-title":"Single- and multi-fraction stereotactic radiosurgery dose tolerances of the optic pathways","volume":"110","author":"Milano","year":"2021","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"6","key":"10.1016\/j.ejmp.2024.104852_b0110","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1120\/jacmp.v16i6.5748","article-title":"A method to improve dose gradient for robotic radiosurgery","volume":"16","author":"Li","year":"2015","journal-title":"J Appl Clin Med Phys"},{"issue":"2","key":"10.1016\/j.ejmp.2024.104852_b0115","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.ijrobp.2019.10.041","article-title":"Dosimetric multicenter planning comparison studies for stereotactic body radiation therapy: methodology and future perspectives","volume":"106","author":"Giglioli","year":"2020","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"2","key":"10.1016\/j.ejmp.2024.104852_b0120","doi-asserted-by":"crossref","first-page":"120","DOI":"10.4103\/jmp.jmp_82_22","article-title":"Multiple brain metastases radiosurgery with cyberknife device: dosimetric comparison between fixed\/iris and multileaf collimator plans","volume":"48","author":"Ianiro","year":"2023","journal-title":"J Med Phys"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179724011098?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179724011098?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,2,12]],"date-time":"2025-02-12T02:26:44Z","timestamp":1739327204000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179724011098"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":24,"alternative-id":["S1120179724011098"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2024.104852","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2024,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Selection criteria for circular collimator- vs. Multileaf collimator-based plans in robotic stereotactic radiotherapy for brain metastases and benign intracranial disease: Impact of target size, shape complexity, and proximity to at-risk organs","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2024.104852","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"104852"}}