{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T01:40:16Z","timestamp":1773020416381,"version":"3.50.1"},"reference-count":35,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2024,11]]},"DOI":"10.1016\/j.ejmp.2024.104854","type":"journal-article","created":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T12:07:35Z","timestamp":1730462855000},"page":"104854","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"special_numbering":"C","title":["Assessment of pencil beam scanning proton therapy beam delivery accuracy through machine learning and log file analysis"],"prefix":"10.1016","volume":"127","author":[{"given":"Ranjith","family":"C.P.","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mayakannan","family":"Krishnan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vysakh","family":"Raveendran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lalit","family":"Chaudhari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siddhartha","family":"Laskar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"153","key":"10.1016\/j.ejmp.2024.104854_b0005","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.radonc.2020.09.038","article-title":"What is plan quality in radiotherapy? The importance of evaluating dose metrics, complexity, and robustness of treatment plans","volume":"1","author":"Hernandez","year":"2020","journal-title":"Radiother Oncol"},{"issue":"4","key":"10.1016\/j.ejmp.2024.104854_b0010","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1002\/acm2.12556","article-title":"Development and long-term stability of a comprehensive daily QA program for a modern pencil beam scanning (PBS) proton therapy delivery system","volume":"20","author":"Rana","year":"2019","journal-title":"J Appl Clin Med Phys"},{"issue":"8","key":"10.1016\/j.ejmp.2024.104854_b0015","doi-asserted-by":"crossref","first-page":"e678","DOI":"10.1002\/mp.13622","article-title":"AAPM task group 224: Comprehensive proton therapy machine quality assurance","volume":"46","author":"Arjomandy","year":"2019","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2024.104854_b0020","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1140\/epjp\/i2011-11066-0","article-title":"Pencil beam characteristics of the next-generation proton scanning gantry of PSI: design issues and initial commissioning results","volume":"126","author":"Pedroni","year":"2011","journal-title":"The European Physical Journal Plus"},{"issue":"9","key":"10.1016\/j.ejmp.2024.104854_b0025","doi-asserted-by":"crossref","first-page":"2455","DOI":"10.1118\/1.1598711","article-title":"Evaluation of the gamma dose distribution comparison method","volume":"30","author":"Low","year":"2003","journal-title":"Med Phys"},{"issue":"3","key":"10.1016\/j.ejmp.2024.104854_b0030","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1120\/jacmp.v16i3.5323","article-title":"Use of a novel two-dimensional ionisation chamber array for pencil beam scanning proton therapy beam quality assurance","volume":"16","author":"Lin","year":"2015","journal-title":"J Appl Clin Med Phys"},{"issue":"20","key":"10.1016\/j.ejmp.2024.104854_b0035","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/aae2f4","article-title":"Alternatives to patient-specific verification measurements in proton therapy: a comparative experimental study with intentional errors","volume":"63","author":"Matter","year":"2018","journal-title":"Phys Med Biol"},{"issue":"11","key":"10.1016\/j.ejmp.2024.104854_b0040","doi-asserted-by":"crossref","first-page":"7139","DOI":"10.1002\/mp.16747","article-title":"Monte Carlo simulation-based patient-specific QA using machine log files for line-scanning proton radiation therapy","volume":"50","author":"Jeon","year":"2023","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2024.104854_b0045","doi-asserted-by":"crossref","unstructured":"Matter M, Nenoff L, Marc L, Weber DC, Lomax AJ, Albertini F. Update on yesterday\u2019s dose\u2014use of delivery log-files for daily adaptive proton therapy (DAPT). Physics in Medicine & Biology. 2020 Sep 23;65(19):195011. https:\/\/doi.org 10.1088\/1361-6560\/ab9f5e.","DOI":"10.1088\/1361-6560\/ab9f5e"},{"issue":"70","key":"10.1016\/j.ejmp.2024.104854_b0050","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.ejmp.2019.12.018","article-title":"Platform for automatic patient quality assurance via Monte Carlo simulations in proton therapy","volume":"1","author":"Marmitt","year":"2020","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2024.104854_b0055","doi-asserted-by":"crossref","unstructured":"Toscano S, Souris K, Goma C, Barrag\u00e1n-Montero A, Puydupin S, Vander Stappen F, Janssens G, Matic A, Geets X, Sterpin E. Impact of machine log-files uncertainties on the quality assurance of proton pencil beam scanning treatment delivery. Physics in Medicine & Biology. 2019 Apr 29;64(9):095021. https:\/\/doi.org 10.1088\/1361-6560\/ab120c.","DOI":"10.1088\/1361-6560\/ab120c"},{"issue":"7","key":"10.1016\/j.ejmp.2024.104854_b0060","doi-asserted-by":"crossref","first-page":"e13972","DOI":"10.1002\/acm2.13972","article-title":"Development of a log file analysis tool for proton patient QA, system performance tracking, and delivered dose reconstruction","volume":"24","author":"Ates","year":"2023","journal-title":"J Appl Clin Med Phys"},{"issue":"2","key":"10.1016\/j.ejmp.2024.104854_b0065","doi-asserted-by":"crossref","DOI":"10.1118\/1.4773312","article-title":"Use treatment log files in spot scanning proton therapy as part of patient-specific quality assurance","volume":"40","author":"Li","year":"2013","journal-title":"Med Phys"},{"issue":"3","key":"10.1016\/j.ejmp.2024.104854_b0070","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s12194-021-00625-3","article-title":"Impact of spot positional errors in robustly optimised intensity-modulated proton therapy plan of craniospinal irradiation","volume":"14","author":"Noufal","year":"2021","journal-title":"Radiol Phys Technol"},{"issue":"7","key":"10.1016\/j.ejmp.2024.104854_b0075","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1002\/acm2.13293","article-title":"Impact of errors in spot size and spot position in robustly optimised pencil beam scanning proton-based stereotactic body radiation therapy (SBRT) lung plans","volume":"22","author":"Rana","year":"2021","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2024.104854_b0080","doi-asserted-by":"crossref","unstructured":"Parodi K, Mairani A, Brons S, Naumann J, Kr\u00e4mer M, Sommerer F, Haberer T. The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study. Physics in Medicine & Biology. 2010 Aug 16;55(17):5169. https:\/\/doi.org \/10.1088\/0031-9155\/55\/17\/018.","DOI":"10.1088\/0031-9155\/55\/17\/018"},{"issue":"12","key":"10.1016\/j.ejmp.2024.104854_b0085","doi-asserted-by":"crossref","first-page":"3979","DOI":"10.1088\/0031-9155\/58\/12\/3979","article-title":"Dosimetric consequences of pencil beam width variations in scanned beam particle therapy","volume":"58","author":"Chanrion","year":"2013","journal-title":"Phys Med Biol"},{"issue":"17","key":"10.1016\/j.ejmp.2024.104854_b0090","doi-asserted-by":"crossref","first-page":"5169","DOI":"10.1088\/0031-9155\/55\/17\/018","article-title":"The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study","volume":"55","author":"Parodi","year":"2010","journal-title":"Phys Med Biol"},{"issue":"57","key":"10.1016\/j.ejmp.2024.104854_b0095","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.ejmp.2018.12.011","article-title":"Impact of spot size variations on dose in scanned proton beam therapy","volume":"1","author":"Kraan","year":"2019","journal-title":"Phys Med"},{"issue":"3","key":"10.1016\/j.ejmp.2024.104854_b0100","doi-asserted-by":"crossref","DOI":"10.1088\/2057-1976\/ad3ce0","article-title":"An artificial neural network based approach for predicting the proton beam spot dosimetric characteristics of a pencil beam scanning technique","volume":"10","author":"Ranjith","year":"2024","journal-title":"Biomed Phys Eng Express"},{"issue":"18","key":"10.1016\/j.ejmp.2024.104854_b0105","article-title":"Application and comparison of machine learning models for predicting quality assurance outcomes in radiation therapy treatment planning","volume":"1","author":"Wall","year":"2020","journal-title":"Inf Med Unlocked"},{"issue":"3","key":"10.1016\/j.ejmp.2024.104854_b0110","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/j.meddos.2021.02.003","article-title":"Mean parotid dose prediction model using machine learning regression method for intensity-modulated radiotherapy in head and neck cancer","volume":"46","author":"Ranjith","year":"2021","journal-title":"Med Dosim"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104854_b0115","article-title":"Improving proton dose calculation accuracy by using deep learning","volume":"2","author":"Wu","year":"2021","journal-title":"Mach Learn: Sci Technol"},{"issue":"1","key":"10.1016\/j.ejmp.2024.104854_b0120","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1186\/s13014-023-02201-y","article-title":"IMPT of head and neck cancer: unsupervised machine learning treatment planning strategy for reducing radiation dermatitis","volume":"18","author":"Padannayil","year":"2023","journal-title":"Radiat Oncol"},{"issue":"78","key":"10.1016\/j.ejmp.2024.104854_b0125","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.ejmp.2020.09.008","article-title":"A machine learning-based framework for delivery error prediction in proton pencil beam scanning using irradiation log-files","volume":"1","author":"Maes","year":"2020","journal-title":"Phys Med"},{"issue":"5","key":"10.1016\/j.ejmp.2024.104854_b0130","doi-asserted-by":"crossref","first-page":"e13911","DOI":"10.1002\/acm2.13911","article-title":"Spot delivery error predictions for intensity modulated proton therapy using robustness analysis with machine learning","volume":"24","author":"Newpower","year":"2023","journal-title":"J Appl Clin Med Phys"},{"issue":"736","key":"10.1016\/j.ejmp.2024.104854_b0135","first-page":"112","article-title":"Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning","volume":"1","author":"Courtois","year":"2014","journal-title":"Nucl Instrum Methods Phys Res, Sect A"},{"key":"10.1016\/j.ejmp.2024.104854_b0140","doi-asserted-by":"crossref","unstructured":"Lin Y, Clasie B, Lu HM, Flanz J, Shen T, Jee KW. Impacts of gantry angle dependent scanning beam properties on proton PBS treatment. Physics in Medicine & Biology. 2016 Dec 20;62(2):344. https:\/\/doi.org \/10.1088\/1361-6560\/aa5084.","DOI":"10.1088\/1361-6560\/aa5084"},{"key":"10.1016\/j.ejmp.2024.104854_b0145","first-page":"2017","article-title":"Forecasting drought using multilayer perceptron artificial neural network model","volume":"2","author":"Ali","year":"2017","journal-title":"Adv Meteorol"},{"key":"10.1016\/j.ejmp.2024.104854_b0150","doi-asserted-by":"crossref","unstructured":"Arjunan M, Krishnan G, Sharma DS, MP N, Patro KC, Thiyagarajan R, Srinivas C, Jalali R. Dosimetric impact of random spot positioning errors in intensity modulated proton therapy plans of small and large volume tumors. The British Journal of Radiology. 2021 Mar 1;94(1119):20201031. https:\/\/doi.org\/10.1259\/bjr.20201031.","DOI":"10.1259\/bjr.20201031"},{"issue":"109","key":"10.1016\/j.ejmp.2024.104854_b0155","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.addr.2016.11.006","article-title":"Proton therapy\u2013present and future","volume":"15","author":"Mohan","year":"2017","journal-title":"Adv Drug Deliv Rev"},{"issue":"2","key":"10.1016\/j.ejmp.2024.104854_b0160","doi-asserted-by":"crossref","first-page":"59","DOI":"10.4103\/jmp.JMP_12_20","article-title":"Characterization and performance evaluation of the first-proton therapy facility in India","volume":"45","author":"Shamurailatpam","year":"2020","journal-title":"Journal of Medical Physics"},{"key":"10.1016\/j.ejmp.2024.104854_b0165","doi-asserted-by":"crossref","first-page":"5287","DOI":"10.1118\/1.4928397","article-title":"Panizza D, et al Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy","volume":"42","author":"Mirandola","year":"2015","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2024.104854_b0170","doi-asserted-by":"crossref","unstructured":"Pidikiti R, Patel BC, Maynard MR, Dugas JP, Syh J, Sahoo N, et al Commissioning of the world's first compact pencil-beam scanning proton therapy system J Appl Clin Med Phys. 2018;19:94\u2013105. https:\/\/doi.org\/10.1002\/acm2.12225.","DOI":"10.1002\/acm2.12225"},{"key":"10.1016\/j.ejmp.2024.104854_b0175","first-page":"154","article-title":"Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas MD Anderson Cancer Center","volume":"37","author":"Gillin","year":"2010","journal-title":"Proton Therapy Center, Houston Med Phys"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179724011116?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179724011116?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,11,7]],"date-time":"2024-11-07T19:59:12Z","timestamp":1731009552000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179724011116"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":35,"alternative-id":["S1120179724011116"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2024.104854","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2024,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Assessment of pencil beam scanning proton therapy beam delivery accuracy through machine learning and log file analysis","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2024.104854","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"104854"}}