{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T00:43:55Z","timestamp":1789001035458,"version":"build-2803163510"},"reference-count":49,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001823","name":"Ministerstvo \u0160kolstv\u00ed, Ml\u00e1de\u017ee a T\u011blov\u00fdchovy","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001823","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2026,2]]},"DOI":"10.1016\/j.ejmp.2026.105718","type":"journal-article","created":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T19:19:30Z","timestamp":1767727170000},"page":"105718","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"special_numbering":"C","title":["Validation of the Tena pregnancy phantom and fetal dose assessment in proton scanning beam therapy"],"prefix":"10.1016","volume":"142","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7528-1984","authenticated-orcid":false,"given":"Natalia","family":"Moj\u017ceszek","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6692-6875","authenticated-orcid":false,"given":"Hrvoje","family":"Brki\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriela","family":"Folty\u0144ska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6649-2138","authenticated-orcid":false,"given":"Olivier Van","family":"Hoey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6712-5540","authenticated-orcid":false,"given":"Hubert","family":"Jab\u0142o\u0144ski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6707-4317","authenticated-orcid":false,"given":"Mladen","family":"Kasabasic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renata","family":"Kope\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katarzyna","family":"Krzempek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-3274-6095","authenticated-orcid":false,"given":"Monika","family":"Lipa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0899-3628","authenticated-orcid":false,"given":"Andrea","family":"Matamoros","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Monika","family":"Radoli\u0144ska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marzena","family":"Rydygier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6322-0615","authenticated-orcid":false,"given":"Tomasz","family":"Sk\u00f3ra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4398-1553","authenticated-orcid":false,"given":"Carlos","family":"Granja","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liliana","family":"Stolarczyk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dawid","family":"Krzempek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2374-3280","authenticated-orcid":false,"given":"Marijke De","family":"Saint-Hubert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejmp.2026.105718_b0005","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2015\/170343","article-title":"Estimating the radiation dose to the fetus in prophylactic internal iliac artery balloon occlusion: three cases","volume":"2015","author":"Kai","year":"2015","journal-title":"Case Rep Obstet Gynecol"},{"key":"10.1016\/j.ejmp.2026.105718_b0010","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1634\/theoncologist.2002-0279","article-title":"Coexistence of pregnancy and malignancy","volume":"7","author":"Pavlidis","year":"2002","journal-title":"Oncologist"},{"key":"10.1016\/j.ejmp.2026.105718_b0015","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/j.gendis.2023.04.008","article-title":"Non-invasive prenatal testing can detect silent cancers in expecting mothers","volume":"11","author":"Ottaiano","year":"2024","journal-title":"Genes Dis"},{"key":"10.1016\/j.ejmp.2026.105718_b0020","doi-asserted-by":"crossref","DOI":"10.1016\/j.radmeas.2021.106665","article-title":"Fetus dose calculation during proton therapy of pregnant phantoms using MCNPX and MCNP6. 2 codes","volume":"149","author":"De Saint-Hubert","year":"2021","journal-title":"Radiat Meas"},{"key":"10.1016\/j.ejmp.2026.105718_b0025","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.critrevonc.2019.02.002","article-title":"Modern radiotherapy in cancer treatment during pregnancy","volume":"136","author":"Mazzola","year":"2019","journal-title":"Crit Rev Oncol Hematol"},{"key":"10.1016\/j.ejmp.2026.105718_b0030","doi-asserted-by":"crossref","unstructured":"Streffer C, Shore R, Konermann G, Meadows A, Holm LE, Stather J, et al. Biological effects after prenatal irradiation (embryo and fetus). A report of the International Commission on Radiological Protection. Ann ICRP 2003;33:5\u2013206.","DOI":"10.1016\/S0146-6453(03)00021-6"},{"key":"10.1016\/j.ejmp.2026.105718_b0035","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1088\/0031-9155\/61\/2\/683","article-title":"Dose assessment for the fetus considering scattered and secondary radiation from photon and proton therapy when treating a brain tumor of the mother","volume":"61","author":"Geng","year":"2015","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.105718_b0040","first-page":"2672","article-title":"Out\u2010of\u2010field doses in pediatric craniospinal irradiations with 3D\u2010CRT, VMAT, and scanning proton radiotherapy: a phantom study","volume":"49","author":"Majer","year":"2022","journal-title":"Wiley Online Library"},{"key":"10.1016\/j.ejmp.2026.105718_b0045","doi-asserted-by":"crossref","DOI":"10.3389\/fonc.2022.904563","article-title":"Out-of-field doses produced by a proton scanning beam inside pediatric anthropomorphic phantoms and their comparison with different photon modalities","volume":"12","author":"Kne\u017eevi\u0107","year":"2022","journal-title":"Front Oncol"},{"key":"10.1016\/j.ejmp.2026.105718_b0050","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1016\/j.ijrobp.2023.09.040","article-title":"Pencil beam scanning proton therapy for pregnant patients with brain and head and neck cancers","volume":"118","author":"Dupere","year":"2024","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2026.105718_b0055","first-page":"33","article-title":"Proton therapy of a pregnant patient with nasopharyngeal carcinoma","volume":"35","author":"Heimovaara","year":"2022","journal-title":"Clin Transl Radiat Oncol"},{"key":"10.1016\/j.ejmp.2026.105718_b0060","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ac4b38","article-title":"Fetal dose from proton pencil beam scanning craniospinal irradiation during pregnancy: a Monte Carlo study","volume":"67","author":"Yeom","year":"2022","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.105718_b0065","doi-asserted-by":"crossref","first-page":"4325","DOI":"10.1088\/0031-9155\/59\/15\/4325","article-title":"The UF Family of hybrid phantoms of the pregnant female for computational radiation dosimetry","volume":"59","author":"Maynard","year":"2014","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.105718_b0070","doi-asserted-by":"crossref","unstructured":"Howell R, Scarboro S, \u2026 SK-P in M&, 2010 undefined. Accuracy of out-of-field dose calculations by a commercial treatment planning system. IopscienceIopOrg 2010;55:6999. https:\/\/doi.org\/10.1088\/0031-9155\/55\/23\/S03.","DOI":"10.1088\/0031-9155\/55\/23\/S03"},{"key":"10.1016\/j.ejmp.2026.105718_b0075","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1002\/acm2.12367","article-title":"Estimating the uncertainty of calculated out\u2010of\u2010field organ dose from a commercial treatment planning system","volume":"19","author":"Wang","year":"2018","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2026.105718_b0080","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1146\/annurev.bioeng.9.060906.151934","article-title":"Computational anthropomorphic models of the human anatomy: the path to realistic monte carlo modeling in radiological sciences","volume":"9","author":"Zaidi","year":"2007","journal-title":"Annu Rev Biomed Eng"},{"key":"10.1016\/j.ejmp.2026.105718_b0085","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.14240","article-title":"Development and validation of the low-cost pregnant female physical phantom for fetal dosimetry in MV photon radiotherapy","volume":"25","author":"Kopa\u010din","year":"2024","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2026.105718_b0090","unstructured":"Energy ECD-G for. Basic Safety Standards Directive \u2013 Better radiation protection. Publications Office; 2018. https:\/\/doi.org\/doi\/10.2833\/062951."},{"key":"10.1016\/j.ejmp.2026.105718_b0095","article-title":"Out-of-field doses for scanning proton radiotherapy of shallowly located paediatric tumours\u2013a comparison of range shifter and 3D printed compensator","author":"Wochnik","year":"2020","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.105718_b0100","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1093\/rpd\/ncx015","article-title":"Out-of-field dose measurements for 3D conformal and intensity modulated radiotherapy of a paediatric brain tumour","volume":"176","author":"Majer","year":"2017","journal-title":"Radiat Prot Dosim"},{"key":"10.1016\/j.ejmp.2026.105718_b0105","doi-asserted-by":"crossref","first-page":"154","DOI":"10.2298\/NTRP2402154F","article-title":"Monte Carlo simulation of photon breast radiotherapy of the pregnant patient - beam characteristics","volume":"39","author":"Faj","year":"2024","journal-title":"Nucl Technol Radiat Protect"},{"key":"10.1016\/j.ejmp.2026.105718_b0110","doi-asserted-by":"crossref","first-page":"541","DOI":"10.2478\/raon-2022-0039","article-title":"Development of a computational pregnant female phantom and calculation of fetal dose during a photon breast radiotherapy","volume":"56","author":"Kopacin","year":"2022","journal-title":"Radiol Oncol"},{"key":"10.1016\/j.ejmp.2026.105718_b0115","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.meddos.2009.05.004","article-title":"Ion Stopping Powers and CT Numbers","volume":"35","author":"Moyers","year":"2010","journal-title":"Med Dosim"},{"key":"10.1016\/j.ejmp.2026.105718_b0120","doi-asserted-by":"crossref","unstructured":"Kulesza J, Adams T, Armstrong J, Bolding S, Brown F, Bull J, et al. MCNP\u00ae Code Version 6.3.0 Theory & User Manual. Los Alamos, NM (United States): 2022. https:\/\/doi.org\/10.2172\/1889957.","DOI":"10.2172\/1889957"},{"key":"10.1016\/j.ejmp.2026.105718_b0125","doi-asserted-by":"crossref","unstructured":"Ferrari A, Sala PR, Fasso A, Ranft J. FLUKA: A Multi-Particle Transport Code. Menlo Park, CA: 2005. https:\/\/doi.org\/10.2172\/877507.","DOI":"10.2172\/877507"},{"key":"10.1016\/j.ejmp.2026.105718_b0130","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.nds.2014.07.049","article-title":"The FLUKA code: developments and challenges for high energy and medical applications","volume":"120","author":"B\u00f6hlen","year":"2014","journal-title":"Nucl Data Sheets"},{"key":"10.1016\/j.ejmp.2026.105718_b0135","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1118\/1.598248","article-title":"A technique for the quantitative evaluation of dose distributions","volume":"25","author":"Low","year":"1998","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105718_b0140","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1109\/TNS.2024.3369972","article-title":"Composition and spectral characterization of mixed-radiation fields with enhanced discrimination by quantum imaging detection","volume":"71","author":"Granja","year":"2024","journal-title":"IEEE Trans Nucl Sci"},{"key":"10.1016\/j.ejmp.2026.105718_b0145","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.nima.2007.08.079","article-title":"Timepix, a 65k programmable pixel readout chip for arrival time, energy and\/or photon counting measurements","volume":"581","author":"Llopart","year":"2007","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"10.1016\/j.ejmp.2026.105718_b0150","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.nima.2018.09.140","article-title":"Directional detection of charged particles and cosmic rays with the miniaturized radiation camera MiniPIX Timepix","volume":"911","author":"Granja","year":"2018","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"10.1016\/j.ejmp.2026.105718_b0155","doi-asserted-by":"crossref","first-page":"S262","DOI":"10.1016\/j.nima.2010.06.183","article-title":"Precise energy calibration of pixel detector working in time-over-threshold mode","volume":"633","author":"Jakubek","year":"2011","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"10.1016\/j.ejmp.2026.105718_b0160","doi-asserted-by":"crossref","DOI":"10.1088\/1748-0221\/19\/04\/C04026","article-title":"Data Processing Engine (DPE): data analysis tool for particle tracking and mixed radiation field characterization with pixel detectors Timepix","volume":"19","author":"Marek","year":"2024","journal-title":"J Instrum"},{"key":"10.1016\/j.ejmp.2026.105718_b0165","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejmp.2023.102529","article-title":"Out-of-field measurements and simulations of a proton pencil beam in a wide range of dose rates using a Timepix3 detector: dose rate, flux and LET","volume":"106","author":"Oancea","year":"2023","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2026.105718_b0170","doi-asserted-by":"crossref","DOI":"10.1016\/j.nima.2020.164901","article-title":"Wide-range tracking and LET-spectra of energetic light and heavy charged particles","volume":"988","author":"Granja","year":"2021","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"10.1016\/j.ejmp.2026.105718_b0175","unstructured":"X-Ray Mass Attenuation Coefficients | NIST n.d. https:\/\/doi.org\/10.18434\/T4D01F."},{"key":"10.1016\/j.ejmp.2026.105718_b0180","doi-asserted-by":"crossref","unstructured":"Granja C, Uhlar R, Chuprakov I, Alexa P, Sansarbayar E, Gledenov YM, et al. Detection of fast neutrons with the pixel detector Timepix3. Journal of Instrumentation 2023;18:P01003. https:\/\/doi.org\/10.1088\/1748-0221\/18\/01\/P01003.","DOI":"10.1088\/1748-0221\/18\/01\/P01003"},{"key":"10.1016\/j.ejmp.2026.105718_b0185","doi-asserted-by":"crossref","DOI":"10.1088\/1748-0221\/18\/11\/C11011","article-title":"Quantum-imaging detection of secondary neutrons in proton radiotherapy fields","volume":"18","author":"Granja","year":"2023","journal-title":"J Instrum"},{"key":"10.1016\/j.ejmp.2026.105718_b0190","doi-asserted-by":"crossref","DOI":"10.3389\/fonc.2022.882489","article-title":"Validation of a Monte Carlo framework for out-of-field dose calculations in proton therapy","volume":"12","author":"De Saint-Hubert","year":"2022","journal-title":"Front Oncol"},{"key":"10.1016\/j.ejmp.2026.105718_b0195","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1118\/1.4938578","article-title":"Experimental evaluation of neutron dose in radiotherapy patients: which dose?","volume":"43","author":"Romero-Exp\u00f3sito","year":"2015","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105718_b0200","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1120\/jacmp.v17i5.6327","article-title":"Spot scanning proton therapy minimizes neutron dose in the setting of radiation therapy administered during pregnancy","volume":"17","author":"Wang","year":"2016","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2026.105718_b0205","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1120\/jacmp.v15i2.4523","article-title":"Relative stopping power measurements to aid in the design of anthropomorphic phantoms for proton radiotherapy","volume":"15","author":"Grant","year":"2014","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2026.105718_b0210","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1120\/jacmp.v16i6.5577","article-title":"Evaluation of detectors for acquisition of pristine depth-dose curves in pencil beam scanning","volume":"16","author":"B\u00e4umer","year":"2015","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2026.105718_b0215","doi-asserted-by":"crossref","first-page":"2309","DOI":"10.1016\/j.asr.2021.04.045","article-title":"Characterization of bubble detectors for space application","volume":"68","author":"Lewis","year":"2021","journal-title":"Adv Space Res"},{"key":"10.1016\/j.ejmp.2026.105718_b0220","doi-asserted-by":"crossref","unstructured":"Van Hoey O et al. Assessment of out-of-field radiation doses in proton therapy by combining in-phantom measurements with different passive detectors. 2025 [at final stage for acceptance for the same special issue of Physica Medica].","DOI":"10.1016\/j.ejmp.2026.105719"},{"key":"10.1016\/j.ejmp.2026.105718_b0225","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1093\/rpd\/ncx254","article-title":"Comparison of response of passive dosimetry systems in scanning proton radiotherapy\u2014a study using paediatric anthropomorphic phantoms","volume":"180","author":"Kne\u017eevi\u0107","year":"2018","journal-title":"Radiat Prot Dosim"},{"key":"10.1016\/j.ejmp.2026.105718_b0230","doi-asserted-by":"crossref","first-page":"5099","DOI":"10.1002\/mp.16897","article-title":"Range shifter contribution to neutron exposure of patients undergoing proton pencil beam scanning","volume":"51","author":"Romero-Exp\u00f3sito","year":"2024","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105718_b0235","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.13957","article-title":"Measurements of fetal dose with Mevion S250i proton therapy system with HYPERSCAN","volume":"24","author":"Hopfensperger","year":"2023","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2026.105718_b0240","article-title":"Treatment of a pregnant patient with a brain tumor using pencil beam scanning proton therapy","author":"Dupere","year":"2024","journal-title":"Adv Radiat Oncol"},{"key":"10.1016\/j.ejmp.2026.105718_b0245","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejmp.2022.102513","article-title":"A review on fetal dose in Radiotherapy: a historical to contemporary perspective","volume":"105","author":"Wong","year":"2023","journal-title":"Phys Med: Eur J Med Phys"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726000050?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726000050?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T07:46:33Z","timestamp":1770450393000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179726000050"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":49,"alternative-id":["S1120179726000050"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.105718","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Validation of the Tena pregnancy phantom and fetal dose assessment in proton scanning beam therapy","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.105718","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"105718"}}