{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T23:17:23Z","timestamp":1782947843223,"version":"3.54.5"},"reference-count":39,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1016\/j.ejmp.2026.105824","type":"journal-article","created":{"date-parts":[[2026,5,31]],"date-time":"2026-05-31T22:06:30Z","timestamp":1780265190000},"page":"105824","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Quantitative accuracy and total-body voxel-based dosimetry of 177Lu molecular radiotherapy using a ring-shaped 360\u00b0 CZT digital SPECT\/CT"],"prefix":"10.1016","volume":"147","author":[{"given":"Panattha","family":"Damthongsen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wuri","family":"Handayani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benchamat","family":"Phromphao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nut","family":"Noipinit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thunyaluk","family":"Sawatnatee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tanawat","family":"Sontrapornpol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Panya","family":"Pasawang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6247-2829","authenticated-orcid":false,"given":"Kitiwat","family":"Khamwan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"5","key":"10.1016\/j.ejmp.2026.105824_b0005","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1148\/39.5.541","article-title":"The use of radioactive tracers in biology and medicine","volume":"39","author":"Hamilton","year":"1942","journal-title":"Radiology"},{"issue":"Supplement 2","key":"10.1016\/j.ejmp.2026.105824_b0010","doi-asserted-by":"crossref","first-page":"13S","DOI":"10.2967\/jnumed.118.220566","article-title":"Future of theranostics: an outlook on precision oncology in nuclear medicine","volume":"60","author":"Langbein","year":"2019","journal-title":"J Nucl Med"},{"issue":"14","key":"10.1016\/j.ejmp.2026.105824_b0015","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1001\/jama.1946.02870490016004","article-title":"Radioactive iodine therapy: effect on functioning metastases of adenocarcinoma of the thyroid","volume":"132","author":"Seidlin","year":"1946","journal-title":"J Am Med Assoc"},{"issue":"6","key":"10.1016\/j.ejmp.2026.105824_b0020","doi-asserted-by":"crossref","first-page":"1778","DOI":"10.1007\/s00259-022-05727-7","article-title":"EANM dosimetry committee recommendations for dosimetry of 177Lu-labelled somatostatin-receptor-and PSMA-targeting ligands","volume":"49","author":"Sj\u00f6green Gleisner","year":"2022","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"11","key":"10.1016\/j.ejmp.2026.105824_b0025","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1007\/s12149-024-01960-2","article-title":"Comparative post-therapeutic dosimetry between 2D planar-based and hybrid-based methods for personalized Lu-177 treatment","volume":"38","author":"Handayani","year":"2024","journal-title":"Ann Nucl Med"},{"issue":"3","key":"10.1016\/j.ejmp.2026.105824_b0030","doi-asserted-by":"crossref","first-page":"1888","DOI":"10.1002\/mp.15444","article-title":"Comparison of voxel S\u2010value methods for personalized voxel\u2010based dosimetry of 177Lu\u2010DOTATATE","volume":"49","author":"Kim","year":"2022","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105824_b0035","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.ejmp.2018.11.001","article-title":"A dosimetry procedure for organs-at-risk in 177Lu peptide receptor radionuclide therapy of patients with neuroendocrine tumours","volume":"56","author":"Marin","year":"2018","journal-title":"Phys Med"},{"issue":"7","key":"10.1016\/j.ejmp.2026.105824_b0040","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.2967\/jnumed.117.201095","article-title":"Whole-body voxel-based personalized dosimetry: the multiple voxel S-value approach for heterogeneous media with nonuniform activity distributions","volume":"59","author":"Lee","year":"2018","journal-title":"J Nucl Med"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0045","first-page":"11S","article-title":"MIRD pamphlet no. 17: the dosimetry of nonuniform activity distributions\u2014radionuclide S values at the voxel level","volume":"40","author":"Bolch","year":"1999","journal-title":"J Nucl Med"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0050","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s40658-020-0284-5","article-title":"Evaluation of a new multipurpose whole-body CZT-based camera: comparison with a dual-head Anger camera and first clinical images","volume":"7","author":"Desmonts","year":"2020","journal-title":"EJNMMI Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0055","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1186\/s40658-024-00684-6","article-title":"360\u00b0 CZT-SPECT\/CT cameras: 99mTc-and 177Lu-phantom-based evaluation under clinical conditions","volume":"11","author":"Hoog","year":"2024","journal-title":"EJNMMI Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0060","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1186\/s40658-023-00576-1","article-title":"Performance study of a 360\u00b0 CZT camera for monitoring 177Lu-PSMA treatment","volume":"10","author":"Vergnaud","year":"2023","journal-title":"EJNMMI Phys"},{"issue":"5","key":"10.1016\/j.ejmp.2026.105824_b0065","doi-asserted-by":"crossref","first-page":"771","DOI":"10.2967\/jnumed.124.268910","article-title":"Assessment of [177Lu] Lu-DOTATATE Dosimetry from High-speed Whole-Body Recordings provided by a 360\u00b0 Cadmium\u2013Zinc\u2013Telluride Camera Compared with results from a conventional Anger-Camera Protocol","volume":"66","author":"Zaragori","year":"2025","journal-title":"J Nucl Med"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0070","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1186\/s40658-023-00586-z","article-title":"Quantitative 177Lu SPECT\/CT imaging for personalized dosimetry using a ring-shaped CZT-based camera","volume":"10","author":"Danieli","year":"2023","journal-title":"EJNMMI Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0075","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/s40658-025-00727-6","article-title":"Towards fully automatized [177Lu] Lu-PSMA personalized dosimetry based on 360\u00b0 CZT whole-body SPECT\/CT: a proof-of-concept","volume":"12","author":"Dieudonn\u00e9","year":"2025","journal-title":"EJNMMI Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0080","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1186\/s40658-024-00627-1","article-title":"Comparison of a 3D CZT and conventional SPECT\/CT system for quantitative Lu-177 SPECT imaging","volume":"11","author":"Nuttens","year":"2024","journal-title":"EJNMMI Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0085","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1186\/s40658-024-00693-5","article-title":"Bias and precision of SPECT-based 177Lu activity-concentration estimation using a ring-configured solid-state versus a dual-headed anger system","volume":"11","author":"Stenvall","year":"2024","journal-title":"EJNMMI Phys"},{"issue":"11","key":"10.1016\/j.ejmp.2026.105824_b0090","doi-asserted-by":"crossref","first-page":"e493","DOI":"10.1097\/RLU.0000000000003169","article-title":"Feasibility of 177Lu therapy monitoring using fast whole-body SPECT recordings provided by a high-speed 360\u00b0 CZT camera","volume":"45","author":"Chevalier","year":"2020","journal-title":"Clin Nucl Med"},{"key":"10.1016\/j.ejmp.2026.105824_b0095","article-title":"Evolving SPECT-CT technology","author":"Willowson","year":"2024","journal-title":"Br J Radiol"},{"key":"10.1016\/j.ejmp.2026.105824_b0100","series-title":"NEMA standards publication NU 2-2018: performance measurements of positron emission tomographs","author":"Association","year":"2018"},{"issue":"8","key":"10.1016\/j.ejmp.2026.105824_b0105","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.13723","article-title":"Experimental evaluation of absolute quantification in 99mTc\u2010TRODAT\u20101 SPECT\/CT brain dopamine transporter (DAT) studies","volume":"23","author":"Zainudin","year":"2022","journal-title":"J Appl Clin Med Phys"},{"issue":"8","key":"10.1016\/j.ejmp.2026.105824_b0110","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.2967\/jnumed.111.100123","article-title":"MIRD pamphlet no. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy","volume":"53","author":"Dewaraja","year":"2012","journal-title":"J Nucl Med"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0115","doi-asserted-by":"crossref","first-page":"151","DOI":"10.2967\/jnumed.115.159012","article-title":"MIRD pamphlet no. 26: joint EANM\/MIRD guidelines for quantitative 177Lu SPECT applied for dosimetry of radiopharmaceutical therapy","volume":"57","author":"Ljungberg","year":"2016","journal-title":"J Nucl Med"},{"issue":"2","key":"10.1016\/j.ejmp.2026.105824_b0120","doi-asserted-by":"crossref","first-page":"483","DOI":"10.21037\/qims-20-1006","article-title":"Recent advances in voxel-based targeted radionuclide therapy dosimetry","volume":"11","author":"Mok","year":"2021","journal-title":"Quant Imaging Med Surg"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0125","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/s13550-016-0172-0","article-title":"Quantitative accuracy of (177)Lu SPECT reconstruction using different compensation methods: phantom and patient studies","volume":"6","author":"Hippel\u00e4inen","year":"2016","journal-title":"EJNMMI Res"},{"issue":"8","key":"10.1016\/j.ejmp.2026.105824_b0130","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.2967\/jnumed.124.267452","article-title":"Dosimetry of [177Lu]Lu-PSMA-Targeted Radiopharmaceutical Therapies in patients with Prostate Cancer: a Comparative Systematic Review and Metaanalysis","volume":"65","author":"Ells","year":"2024","journal-title":"J Nucl Med"},{"issue":"2","key":"10.1016\/j.ejmp.2026.105824_b0135","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1007\/s40336-023-00589-x","article-title":"Dosimetry in Lu-177-DOTATATE peptide receptor radionuclide therapy: a systematic review","volume":"12","author":"Nautiyal","year":"2024","journal-title":"Clinical and Translational Imaging"},{"issue":"8","key":"10.1016\/j.ejmp.2026.105824_b0140","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.2967\/jnumed.124.267452","article-title":"Dosimetry of [177Lu] Lu-PSMA\u2013targeted radiopharmaceutical therapies in patients with prostate cancer: a comparative systematic review and metaanalysis","volume":"65","author":"Ells","year":"2024","journal-title":"J Nucl Med"},{"issue":"3","key":"10.1016\/j.ejmp.2026.105824_b0145","first-page":"292","article-title":"Examining absorbed doses of indigenously developed 177Lu-PSMA-617 in metastatic castration-resistant prostate cancer patients at baseline and during course of peptide receptor radioligand therapy","volume":"36","author":"Kamaldeep","year":"2021","journal-title":"Cancer Biother Radiopharm"},{"issue":"11","key":"10.1016\/j.ejmp.2026.105824_b0150","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1007\/s12149-021-01659-8","article-title":"Patient dosimetry of 177Lu-PSMA I&T in metastatic prostate cancer treatment: the experience in Thailand","volume":"35","author":"Chatachot","year":"2021","journal-title":"Ann Nucl Med"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0155","doi-asserted-by":"crossref","first-page":"33","DOI":"10.2967\/jnumed.112.107524","article-title":"Individualized dosimetry of kidney and bone marrow in patients undergoing 177Lu-DOTA-octreotate treatment","volume":"54","author":"Sandstr\u00f6m","year":"2013","journal-title":"J Nucl Med"},{"key":"10.1016\/j.ejmp.2026.105824_b0160","first-page":"1590","article-title":"Feasibility of total body dosimetry of Lu-177 SPECT-CT images recorded by a CZT camera","volume":"62(Suppl 1)","author":"Imbert","year":"2021","journal-title":"J Nucl Med"},{"issue":"2","key":"10.1016\/j.ejmp.2026.105824_b0165","doi-asserted-by":"crossref","first-page":"e111","DOI":"10.1097\/RLU.0000000000001026","article-title":"Localization of Radiolabeled Somatostatin Analogs in the Spleen","volume":"41","author":"Melis","year":"2016","journal-title":"Clin Nucl Med"},{"issue":"7","key":"10.1016\/j.ejmp.2026.105824_b0170","doi-asserted-by":"crossref","first-page":"2143","DOI":"10.1182\/blood.V82.7.2143.2143","article-title":"In vitro autoradiographic and in vivo scintigraphic localization of somatostatin receptors in human lymphatic tissue","volume":"82","author":"Reubi","year":"1993","journal-title":"Blood"},{"key":"10.1016\/j.ejmp.2026.105824_b0175","first-page":"1","article-title":"Current prospects and Future Directions of Single Time Point Dosimetry in Radiopharmaceutical Therapy: a Systematic Review. Nuclear Medicine and Molecular","author":"Sadeghi","year":"2025","journal-title":"Imaging"},{"issue":"5","key":"10.1016\/j.ejmp.2026.105824_b0180","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/j.oooo.2018.01.011","article-title":"Physiologic distribution of PSMA-ligand in salivary glands and seromucous glands of the head and neck on PET\/CT","volume":"125","author":"Nulent","year":"2018","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"issue":"2","key":"10.1016\/j.ejmp.2026.105824_b0185","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/MNM.0000000000001792","article-title":"Estimation of absorbed dose to salivary glands in mCRPC patients undergoing 177Lu-PSMA-617 radioligand therapy using quantitative SPECT-CT at single time point: a single-center feasibility study","volume":"45","author":"Kaur","year":"2024","journal-title":"Nucl Med Commun"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105824_b0190","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1186\/s40658-023-00576-1","article-title":"Performance study of a 360\u00b0 CZT camera for monitoring (177)Lu-PSMA treatment","volume":"10","author":"Vergnaud","year":"2023","journal-title":"EJNMMI Phys"},{"issue":"8","key":"10.1016\/j.ejmp.2026.105824_b0195","doi-asserted-by":"crossref","first-page":"2250","DOI":"10.1007\/s00259-023-06176-6","article-title":"SPECT at the speed of PET: a feasibility study of CZT-based whole-body SPECT\/CT in the post (177)Lu-DOTATATE and (177)Lu-PSMA617 setting","volume":"50","author":"Song","year":"2023","journal-title":"Eur J Nucl Med Mol Imaging"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726001110?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726001110?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T22:30:06Z","timestamp":1782945006000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179726001110"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":39,"alternative-id":["S1120179726001110"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.105824","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Quantitative accuracy and total-body voxel-based dosimetry of 177Lu molecular radiotherapy using a ring-shaped 360\u00b0 CZT digital SPECT\/CT","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.105824","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"105824"}}