{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T22:50:36Z","timestamp":1792104636060,"version":"4.4.0"},"reference-count":37,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T00:00:00Z","timestamp":1782345600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100018537","name":"National Science and Technology Major Project","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100018537","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100013076","name":"National Major Science and Technology Projects of China","doi-asserted-by":"publisher","award":["2024ZD0519901"],"award-info":[{"award-number":["2024ZD0519901"]}],"id":[{"id":"10.13039\/501100013076","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.ejmp.2026.105856","type":"journal-article","created":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T09:23:44Z","timestamp":1782293024000},"page":"105856","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["A rapid script-based framework for rotational robustness evaluation in lateral-opposed IMPT under customized setup scenarios"],"prefix":"10.1016","volume":"148","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-6407-479X","authenticated-orcid":false,"given":"Jiajun","family":"Zheng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hui","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liming","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hailun","family":"Pan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuming","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-5569-7866","authenticated-orcid":false,"given":"Yuanlin","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenqin","family":"Cai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunsheng","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yibin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiayi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"8","key":"10.1016\/j.ejmp.2026.105856_b1","doi-asserted-by":"crossref","first-page":"R155","DOI":"10.1088\/0031-9155\/60\/8\/R155","article-title":"The physics of proton therapy","volume":"60","author":"Newhauser","year":"2015","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.105856_b2","article-title":"Robust angle selection in particle therapy","volume":"11","author":"Zhou","year":"2021","journal-title":"Front Oncol"},{"issue":"2","key":"10.1016\/j.ejmp.2026.105856_b3","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.ijrobp.2007.03.018","article-title":"Radiotherapy treatment of early-stage prostate cancer with IMRT and protons: a treatment planning comparison","volume":"69","author":"Trofimov","year":"2007","journal-title":"Int J Radiat Oncology* Biology* Phys"},{"key":"10.1016\/j.ejmp.2026.105856_b4","article-title":"The status and challenges for prostate stereotactic body radiation therapy treatments in United States proton therapy centers: An NRG oncology practice survey","volume":"11","author":"Shen","year":"2024","journal-title":"Int J Part Ther"},{"issue":"3","key":"10.1016\/j.ejmp.2026.105856_b5","doi-asserted-by":"crossref","first-page":"432","DOI":"10.3171\/jns.1999.91.3.0432","article-title":"Proton radiation therapy for chordomas and chondrosarcomas of the skull base","volume":"91","author":"Hug","year":"1999","journal-title":"J Neurosurg"},{"key":"10.1016\/j.ejmp.2026.105856_b6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13014-014-0279-2","article-title":"Dosimetric robustness against setup errors in charged particle radiotherapy of skull base tumors","volume":"9","author":"Ammazzalorso","year":"2014","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.ejmp.2026.105856_b7","doi-asserted-by":"crossref","DOI":"10.3389\/fonc.2023.1161752","article-title":"The role of particle radiotherapy in the treatment of skull base tumors","volume":"13","author":"Iannalfi","year":"2023","journal-title":"Front Oncol"},{"issue":"8","key":"10.1016\/j.ejmp.2026.105856_b8","doi-asserted-by":"crossref","first-page":"e678","DOI":"10.1002\/mp.13622","article-title":"AAPM task group 224: comprehensive proton therapy machine quality assurance","volume":"46","author":"Arjomandy","year":"2019","journal-title":"Med Phys"},{"issue":"2","key":"10.1016\/j.ejmp.2026.105856_b9","doi-asserted-by":"crossref","first-page":"111","DOI":"10.14338\/IJPT-23-00004.1","article-title":"Novel monthly quality assurance regimen and 5-year analysis using a proton metrology system","volume":"10","author":"Ates","year":"2023","journal-title":"Int J Part Ther"},{"issue":"11","key":"10.1016\/j.ejmp.2026.105856_b10","doi-asserted-by":"crossref","first-page":"R99","DOI":"10.1088\/0031-9155\/57\/11\/R99","article-title":"Range uncertainties in proton therapy and the role of Monte Carlo simulations","volume":"57","author":"Paganetti","year":"2012","journal-title":"Phys Med Biol"},{"issue":"2","key":"10.1016\/j.ejmp.2026.105856_b11","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1118\/1.3679340","article-title":"Robust optimization of intensity modulated proton therapy","volume":"39","author":"Liu","year":"2012","journal-title":"Med Phys"},{"issue":"22","key":"10.1016\/j.ejmp.2026.105856_b12","doi-asserted-by":"crossref","first-page":"22TR02","DOI":"10.1088\/1361-6560\/aae659","article-title":"Robust radiotherapy planning","volume":"63","author":"Unkelbach","year":"2018","journal-title":"Phys Med Biol"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105856_b13","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1118\/1.3021139","article-title":"Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning","volume":"36","author":"Unkelbach","year":"2009","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105856_b14","doi-asserted-by":"crossref","DOI":"10.1016\/j.radonc.2024.110365","article-title":"Robustness evaluation of pencil beam scanning proton therapy treatment planning: A systematic review","author":"Sterpin","year":"2024","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2026.105856_b15","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.radonc.2019.09.010","article-title":"Multiple-CT optimization: An adaptive optimization method to account for anatomical changes in intensity-modulated proton therapy for head and neck cancers","volume":"142","author":"Yang","year":"2020","journal-title":"Radiother Oncol"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105856_b16","first-page":"75","article-title":"Stereotactic body proton therapy for early stage non-small cell lung cancer\u2013technical challenges and solutions: The MD Anderson experience","volume":"9","author":"Zhu","year":"2023","journal-title":"J Radiosurgery SBRT"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105856_b17","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1186\/s13014-022-02126-y","article-title":"Assessment of IMPT versus VMAT plans using different uncertainty scenarios for prostate cancer","volume":"17","author":"Butkus","year":"2022","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.ejmp.2026.105856_b18","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.ejmp.2020.11.035","article-title":"Assessment of daily dose accumulation for robustly optimized intensity modulated proton therapy treatment of prostate cancer","volume":"81","author":"Xu","year":"2021","journal-title":"Phys Medica"},{"key":"10.1016\/j.ejmp.2026.105856_b19","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.phro.2018.06.002","article-title":"A biological modelling based comparison of radiotherapy plan robustness using photons vs protons for focal prostate boosting","volume":"6","author":"Pedersen","year":"2018","journal-title":"Phys Imaging Radiat Oncol"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105856_b20","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.meddos.2023.10.009","article-title":"Treatment planning of scanned proton beams in RayStation","volume":"49","author":"Janson","year":"2024","journal-title":"Med Dosim"},{"issue":"2","key":"10.1016\/j.ejmp.2026.105856_b21","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.meddos.2018.03.006","article-title":"3D treatment planning system\u2014Varian eclipse for proton therapy planning","volume":"43","author":"Sahoo","year":"2018","journal-title":"Med Dosim"},{"key":"10.1016\/j.ejmp.2026.105856_b22","first-page":"52","article-title":"Errors and margins in radiotherapy","volume":"vol. 14","author":"Van Herk","year":"2004"},{"issue":"3","key":"10.1016\/j.ejmp.2026.105856_b23","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1016\/j.ijrobp.2006.05.055","article-title":"Pitch, roll, and yaw variations in patient positioning","volume":"66","author":"Kaiser","year":"2006","journal-title":"Int J Radiat Oncology* Biology* Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105856_b24","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.ijrobp.2008.08.042","article-title":"Dosimetric changes resulting from patient rotational setup errors in proton therapy prostate plans","volume":"75","author":"Sejpal","year":"2009","journal-title":"Int J Radiat Oncology* Biology* Phys"},{"issue":"2","key":"10.1016\/j.ejmp.2026.105856_b25","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.ijrobp.2009.07.1696","article-title":"Spot scanning proton beam therapy for prostate cancer: treatment planning technique and analysis of consequences of rotational and translational alignment errors","volume":"78","author":"Meyer","year":"2010","journal-title":"Int J Radiat Oncology* Biology* Phys"},{"issue":"3","key":"10.1016\/j.ejmp.2026.105856_b26","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/j.meddos.2013.03.007","article-title":"Multifield optimization intensity-modulated proton therapy (MFO-IMPT) for prostate cancer: robustness analysis through simulation of rotational and translational alignment errors","volume":"38","author":"Pugh","year":"2013","journal-title":"Med Dosim"},{"issue":"4","key":"10.1016\/j.ejmp.2026.105856_b27","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1093\/jrr\/rrab044","article-title":"Dosimetric impact of rotational setup errors in volumetric modulated arc therapy for postoperative cervical cancer","volume":"62","author":"Tsujii","year":"2021","journal-title":"J Radiat Res"},{"issue":"7","key":"10.1016\/j.ejmp.2026.105856_b28","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1002\/acm2.13322","article-title":"Radiobiological evaluation considering setup error on single-isocenter irradiation in stereotactic radiosurgery","volume":"22","author":"Nakano","year":"2021","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"10.1016\/j.ejmp.2026.105856_b29","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1002\/acm2.12815","article-title":"Dosimetric impact of rotational errors on the quality of VMAT-SRS for multiple brain metastases: comparison between single-and two-isocenter treatment planning techniques","volume":"21","author":"Prentou","year":"2020","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105856_b30","doi-asserted-by":"crossref","first-page":"01NT02","DOI":"10.1088\/1361-6560\/aca874","article-title":"Introduce a rotational robust optimization framework for spot-scanning proton arc (sparc) therapy","volume":"68","author":"Chang","year":"2022","journal-title":"Phys Med Biol"},{"issue":"2","key":"10.1016\/j.ejmp.2026.105856_b31","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.13510","article-title":"Validation of automated complex head and neck treatment planning with pencil beam scanning proton therapy","volume":"23","author":"Hedrick","year":"2022","journal-title":"J Appl Clin Med Phys"},{"issue":"10","key":"10.1016\/j.ejmp.2026.105856_b32","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1007\/s41365-023-01293-1","article-title":"SAPT: a synchrotron-based proton therapy facility in Shanghai","volume":"34","author":"Zhang","year":"2023","journal-title":"Nucl Sci Tech"},{"issue":"1055","key":"10.1016\/j.ejmp.2026.105856_b33","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20150468","article-title":"Are pitch and roll compensations required in all pathologies? A data analysis of 2945 fractions","volume":"88","author":"Mancosu","year":"2015","journal-title":"Br J Radiol"},{"key":"10.1016\/j.ejmp.2026.105856_b34","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1007\/s12194-016-0347-4","article-title":"Impact of pitch angle setup error and setup error correction on dose distribution in volumetric modulated arc therapy for prostate cancer","volume":"9","author":"Takemura","year":"2016","journal-title":"Radiol Phys Technol"},{"issue":"11","key":"10.1016\/j.ejmp.2026.105856_b35","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6501\/ab9239","article-title":"Analysis and improvement of the positioning accuracy of rotary axes of compound machine tools based on pitch error compensation","volume":"31","author":"Wu","year":"2020","journal-title":"Meas Sci Technol"},{"issue":"1","key":"10.1016\/j.ejmp.2026.105856_b36","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1118\/1.2138009","article-title":"A method to implement full six-degree target shift corrections for rigid body in image-guided radiotherapy","volume":"33","author":"Yue","year":"2006","journal-title":"Med Phys"},{"issue":"9","key":"10.1016\/j.ejmp.2026.105856_b37","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.14043","article-title":"Dosimetric effect of six degrees of freedom couch top with rotational setup error corrections in proton therapy","volume":"24","author":"Kato","year":"2023","journal-title":"J Appl Clin Med Phys"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726001432?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726001432?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T22:42:01Z","timestamp":1792104121000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179726001432"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":37,"alternative-id":["S1120179726001432"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.105856","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A rapid script-based framework for rotational robustness evaluation in lateral-opposed IMPT under customized setup scenarios","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.105856","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"105856"}}