{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T23:43:45Z","timestamp":1792107825019,"version":"4.4.0"},"reference-count":27,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T00:00:00Z","timestamp":1781654400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003196","name":"Ministry of Health","doi-asserted-by":"publisher","award":["PNRR-POC-2022-12376062"],"award-info":[{"award-number":["PNRR-POC-2022-12376062"]}],"id":[{"id":"10.13039\/501100003196","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100013168","name":"Istituto Nazionale di Fisica Nucleare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100013168","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004007","name":"Istituto Nazionale di Fisica Nucleare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004007","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000780","name":"European Commission","doi-asserted-by":"publisher","award":["PNRR-POC-2022-12376062"],"award-info":[{"award-number":["PNRR-POC-2022-12376062"]}],"id":[{"id":"10.13039\/501100000780","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.ejmp.2026.105859","type":"journal-article","created":{"date-parts":[[2026,6,28]],"date-time":"2026-06-28T09:10:01Z","timestamp":1782637801000},"page":"105859","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["VIT-MBRT, a GPU accelerated Monte Carlo tool for investigations on preclinical minibeam radiation therapy"],"prefix":"10.1016","volume":"148","author":[{"given":"N.","family":"Luongo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"U.","family":"Crimaldi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9449-9927","authenticated-orcid":false,"given":"L.A.","family":"Cerbone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6159-2909","authenticated-orcid":false,"given":"X.","family":"Jia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Y.","family":"Lai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Clemente","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Oliviero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Pacelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Spinelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Fiorino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-1967-3701","authenticated-orcid":false,"given":"S.","family":"Pizzardi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9409-0008","authenticated-orcid":false,"given":"P.","family":"Russo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6606-4304","authenticated-orcid":false,"given":"G.","family":"Mettivier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejmp.2026.105859_b0005","doi-asserted-by":"crossref","first-page":"685","DOI":"10.3390\/cancers14030685","article-title":"Treatment planning study for microbeam radiotherapy using clinical patient data","volume":"14","author":"Kraus","year":"2022","journal-title":"Cancers"},{"key":"10.1016\/j.ejmp.2026.105859_b0010","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.1118\/1.596771","article-title":"Microbeam radiation therapy","volume":"19","author":"Slatkin","year":"1992","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105859_b0015","doi-asserted-by":"crossref","unstructured":"Donzelli A., Br\u00e4uer-Krisch E., Nemoz C., Brochard T., Oelfke U., \u201cConformal image-guided microbeam radiation therapy at the ESRF biomedical beamline ID17\u201d, Med. Phys. 43, 6(1), 2016, 3157\u2013 67. https:\/\/doi.org\/10.1118\/1.4950724.","DOI":"10.1118\/1.4950724"},{"key":"10.1016\/j.ejmp.2026.105859_b0020","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1107\/S1600577515022894","article-title":"\u201cImage guidance protocol for synchrotron microbeam radiation therapy","volume":"23","author":"Pelliccia","year":"2016","journal-title":"J Synchrotron Rad\u201d"},{"issue":"8","key":"10.1016\/j.ejmp.2026.105859_b0025","doi-asserted-by":"crossref","first-page":"4669","DOI":"10.1118\/1.4728220","article-title":"Monte Carlo simulation of a compact microbeam radiotherapy system based on carbon nanotube field emission technology","volume":"39","author":"Schreiber","year":"2012","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105859_b0030","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ab7361","article-title":"\u201cDose profiles and x-ray energy optimization for microbeam radiation therapy by high-dose, high resolution dosimetry using Sm-doped fluoroaluminate glass plates and Monte Carlo transport simulation\u201d to cite this article","volume":"65","author":"Chicilo","year":"2020","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.105859_b0035","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.ejmp.2017.12.017","article-title":"Experimental optimisation of the X-ray energy in microbeam radiation Therapy","volume":"45","author":"Livingstone","year":"2018","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2026.105859_b0040","first-page":"395","article-title":"Optimization of x-ray microplanar beam radiation therapy for deep-seated tumours by a simulation study","volume":"22","author":"Shinohara","year":"2014","journal-title":"J Xray Sci Technol"},{"key":"10.1016\/j.ejmp.2026.105859_b0045","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.ejmp.2019.03.019","article-title":"Identifying optimal clinical scenarios for synchrotron microbeam radiation therapy: a treatment planning study","volume":"60","author":"Smyth","year":"2019","journal-title":"Phys Med"},{"issue":"8","key":"10.1016\/j.ejmp.2026.105859_b0050","doi-asserted-by":"crossref","first-page":"3568","DOI":"10.1118\/1.3166186","article-title":"Gadolinium dose enhancement studies in microbeam radiation therapy","volume":"36","author":"Prezado","year":"2009","journal-title":"Med Phys"},{"issue":"12","key":"10.1016\/j.ejmp.2026.105859_b0055","doi-asserted-by":"crossref","first-page":"6301","DOI":"10.1118\/1.4966032","article-title":"A preclinical microbeam facility with a conventional x-ray tube","volume":"43","author":"Bartzsch","year":"2016","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105859_b0060","doi-asserted-by":"crossref","first-page":"103420","DOI":"10.1016\/j.ejmp.2024.103420","article-title":"Preclinical photon minibeam radiotherapy using a custom collimator: Dosimetry characterization and preliminary in-vivo results on a glioma model","volume":"124","author":"Akbas","year":"2024","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2026.105859_b0065","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejmp.2025.104894","article-title":"Real-time dose measurement in minibeam radiotherapy using radioluminescence imaging","volume":"130","author":"Marson","year":"2025","journal-title":"Phys Med"},{"key":"10.1016\/j.ejmp.2026.105859_b0070","doi-asserted-by":"crossref","first-page":"29926","DOI":"10.1038\/s41598-025-15281-5","article-title":"Development of a preclinical X-rays minibeam Monte Carlo treatment planning system","volume":"15","author":"Pizzardi","year":"2025","journal-title":"Sci Rep"},{"key":"10.1016\/j.ejmp.2026.105859_b0075","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1088\/0031-9155\/57\/3\/577","article-title":"Fast monte carlo simulation for patient-specific CT\/CBCT imaging dose calculation","volume":"57","author":"Jia","year":"2012","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.105859_b0080","doi-asserted-by":"crossref","first-page":"7368","DOI":"10.1118\/1.4766436","article-title":"A GPU tool for efficient accurate and realistic simulation of cone-beam CT projections","volume":"39","author":"Jia","year":"2012","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105859_b0085","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/adc9f6","article-title":"Absorbed and effective dose estimates in HR-pQCT of the distal radius and tibia: virtual dosimetry with a GPU-accelerated Monte Carlo code","volume":"70","author":"Cerbone","year":"2025","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.105859_b0090","unstructured":"Woodcock E., Murphy T., Hemmings P. and Longworth S. \u201cTechniques used in the GEM code for Monte Carlo neutronics calculations in reactors and other systems of complex geometry. In: Applications of Computing Methods to Reactor Problems\u201d, Argonne National Laboratories Report, 1965, pp 40 ANL-7050."},{"key":"10.1016\/j.ejmp.2026.105859_b0095","unstructured":"Berger, M.J., Coursey, J.S., Zucker, M.A., and Chang, J. (2005),\u201cESTAR, PSTAR, and ASTAR: Computer Programs for Calculating Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions(version1.2.3)\u201d. [Online] Available: http:\/\/physics.nist.gov\/Star, 2025, National Institute of Standards and Technology, Gaithersburg, MD."},{"key":"10.1016\/j.ejmp.2026.105859_b0100","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ad2012","article-title":"Virtual dosimetry study with three cone-beam breast computed tomography scanners using a fast GPU-based Monte Carlo code","volume":"69","author":"Mettivier","year":"2024","journal-title":"Phys Med Biol"},{"issue":"4","key":"10.1016\/j.ejmp.2026.105859_b0105","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.3390\/cancers14041027","article-title":"Virtual clinical trials in 2D and 3D X-ray breast imaging and dosimetry: comparison of CPU-based and GPU-based Monte Carlo codes","volume":"14","author":"Mettivier","year":"2022","journal-title":"Cancers"},{"issue":"11","key":"10.1016\/j.ejmp.2026.105859_b0110","doi-asserted-by":"crossref","first-page":"6818","DOI":"10.1118\/1.4758060","article-title":"TOPAS: an innovative proton Monte Carlo platform for research and clinical applications","volume":"39","author":"Perl","year":"2012","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105859_b0115","doi-asserted-by":"crossref","first-page":"N433","DOI":"10.1088\/0031-9155\/54\/19\/N01","article-title":"SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes","volume":"54","author":"Poludniowski","year":"2009","journal-title":"Phys Med Biol"},{"issue":"12","key":"10.1016\/j.ejmp.2026.105859_b0120","doi-asserted-by":"crossref","first-page":"2745","DOI":"10.1118\/1.1517611","article-title":"History by history statistical estimators in the BEAM code system","volume":"29","author":"Walters","year":"2002","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.105859_b0125","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","article-title":"NIH image to ImageJ: 25 years of image analysis","volume":"9","author":"Schneider","year":"2012","journal-title":"Nat Methods"},{"key":"10.1016\/j.ejmp.2026.105859_b0130","first-page":"1990","article-title":"Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients from 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest","volume":"1989","author":"Hubbell","year":"1996","journal-title":"Radiation Physics Division, PML, NIST"},{"key":"10.1016\/j.ejmp.2026.105859_b0135","doi-asserted-by":"crossref","first-page":"17696","DOI":"10.1038\/s41598-019-53991-9","article-title":"Validation of a Monte Carlo simulation for microbeam radiation therapy on the imaging and medical beamline at the Australian synchrotron","volume":"9","author":"Dipuglia","year":"2019","journal-title":"Sci Rep"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726001468?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726001468?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T22:43:53Z","timestamp":1792104233000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179726001468"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":27,"alternative-id":["S1120179726001468"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.105859","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"VIT-MBRT, a GPU accelerated Monte Carlo tool for investigations on preclinical minibeam radiation therapy","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.105859","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"105859"}}