{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T03:45:07Z","timestamp":1791863107181,"version":"4.3.4"},"reference-count":40,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T00:00:00Z","timestamp":1789948800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002322","name":"CAPES","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002322","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.ejmp.2026.107189","type":"journal-article","created":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T03:29:47Z","timestamp":1789615787000},"page":"107189","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Dosimetry with LIF:Mg,Ti (TLD-100) for locating non-paubable breast cancer using Iodine-125 seeds"],"prefix":"10.1016","volume":"150","author":[{"given":"Hamona Novaes","family":"Santos","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carla","family":"Daruich de Souza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucas Verdi","family":"Angelocci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto Kenji","family":"Sakuraba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paula Guimar\u00e3es","family":"Antunes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos Alberto","family":"Zeituni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Elisa Chuery Martins","family":"Rostelato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejmp.2026.107189_b0005","doi-asserted-by":"crossref","first-page":"441","DOI":"10.3390\/diagnostics14040441","article-title":"Radioactive seed localization for nonpalpable breast lesions: systematic review and meta-analysis","volume":"14","author":"Ferreira","year":"2024","journal-title":"Diagnostics"},{"key":"10.1016\/j.ejmp.2026.107189_b0010","doi-asserted-by":"crossref","first-page":"2261","DOI":"10.1016\/j.ejso.2017.09.021","article-title":"Patient satisfaction with radioguided occult lesion localisation using iodine-125 seeds (\u2018ROLLIS\u2019) versus conventional hookwire localisation","volume":"43","author":"Ong","year":"2017","journal-title":"Eur J Surg Oncol"},{"key":"10.1016\/j.ejmp.2026.107189_b0015","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1016\/j.acra.2006.03.017","article-title":"Radiation safety with use of I-125 seeds for localization of nonpalpable breast lesions","volume":"13","author":"Pavlicek","year":"2006","journal-title":"Acad Radiol"},{"key":"10.1016\/j.ejmp.2026.107189_b0020","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ab0149","article-title":"Development and application of a simple method for calculating breast dose from radio-guided occult lesion localisation using iodine-125 seeds (ROLLIS)","volume":"64","author":"Reed","year":"2019","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.107189_b0025","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.clinimag.2020.12.008","article-title":"Pre-operative localization of impalpable breast lesions using iodine 125 seeds: placement accuracy and multidisciplinary challenges","volume":"73","author":"Frost","year":"2021","journal-title":"Clin Imaging"},{"key":"10.1016\/j.ejmp.2026.107189_b0030","unstructured":"Princeton University, 2015. Iodine-125. https:\/\/ehs.princeton.edu\/laboratory-research\/radiation-safety\/radioactive-materials\/radioisotope-fact-sheets\/iodine-125."},{"key":"10.1016\/j.ejmp.2026.107189_b0035","unstructured":"Best Medical, 2020. Radioactive Seeds, http:\/\/www.bestmedical.com\/product_seeds_ip.html."},{"key":"10.1016\/j.ejmp.2026.107189_b0040","doi-asserted-by":"crossref","DOI":"10.1016\/j.apradiso.2020.109307","article-title":"New core configuration for the fabrication of 125I radioactive sources for cancer treatment","volume":"165","author":"Daruich de Souza","year":"2020","journal-title":"Appl Radiat Isotopes"},{"key":"10.1016\/j.ejmp.2026.107189_b0045","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1111\/1754-9485.12302","article-title":"Radioguided occult lesion localisation using iodine-125 seeds (\u2018ROLLIS\u2019) for removal of impalpable breast lesions: first Australian experience","volume":"59","author":"Taylor","year":"2015","journal-title":"J Med Imaging Radiat Oncol"},{"key":"10.1016\/j.ejmp.2026.107189_b0050","doi-asserted-by":"crossref","unstructured":"Pouw, B., de Wit-van der Veen, L.J., Stokkel, M.P., Loo, C.E., Vrancken Peeters, M.J., Vald\u00e9s Olmos, R.A., 2015. Heading toward radioactive seed localization in non-palpable breast cancer surgery? A meta-analysis. J Surg Oncol 111, 185\u2013191.","DOI":"10.1002\/jso.23785"},{"key":"10.1016\/j.ejmp.2026.107189_b0055","series-title":"Thermoluminescence dosimetry materials: properties and uses","author":"McKeever","year":"1995"},{"key":"10.1016\/j.ejmp.2026.107189_b0060","unstructured":"Thermo Fisher Scientific, 2020. TLD-100\u2122 Thermoluminescent Dosimetry Material, https:\/\/www.thermofisher.com\/order\/catalog\/product\/SNO10106, p. May 27."},{"key":"10.1016\/j.ejmp.2026.107189_b0065","doi-asserted-by":"crossref","unstructured":"Griffiths, H.J., 1992. Recommendations of the International Commission on Radiological Protection. Annals of the ICRP Publication 60. Radiology 182.","DOI":"10.1148\/radiology.182.3.692-a"},{"key":"10.1016\/j.ejmp.2026.107189_b0070","unstructured":"International Commission on Radiological Protection, 1991. ICRP 60: Occupational radiological protection in interventional procedures, Recommendations of the International Commission on Radiological Protection. International Commission on Radiological Protection. ICRP Publication 21, https:\/\/www.icrp.org\/publication.asp?id=icrp%20publication%2060."},{"key":"10.1016\/j.ejmp.2026.107189_b0075","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/j.radmeas.2014.05.005","article-title":"The use of TLDs for brachytherapy dosimetry","volume":"71","author":"DeWerd","year":"2014","journal-title":"Radiat Measur"},{"key":"10.1016\/j.ejmp.2026.107189_b0080","unstructured":"Reed, J.L., 2014. Determina\u00e7\u00e3o da depend\u00eancia energ\u00e9tica intr\u00ednseca de dos\u00edmetros termoluminescentes LiF:Mg, Ti para fontes de braquiterapia de 125I e 103Pd em rela\u00e7\u00e3o ao 60Co. . F\u00edsica M\u00e9dica 41."},{"key":"10.1016\/j.ejmp.2026.107189_b0085","doi-asserted-by":"crossref","DOI":"10.1016\/j.radmeas.2020.106342","article-title":"Fading study and readout optimization for routinely use of LiF:Mg,Ti thermoluminescent detectors for personal dosimetry","volume":"135","author":"Sorger","year":"2020","journal-title":"Radiat Meas"},{"key":"10.1016\/j.ejmp.2026.107189_b0090","doi-asserted-by":"crossref","unstructured":"Rivard, M.J., Coursey, B.M., DeWerd, L.A., Hanson, W.F., Huq, M.S., Ibbott, G.S., et al., 2004. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. AAPM- American Association of Physics in Medicine, https:\/\/www.aapm.org\/pubs\/reports\/rpt_84.pdf, p. 42.","DOI":"10.1118\/1.1646040"},{"key":"10.1016\/j.ejmp.2026.107189_b0095","unstructured":"Los Alamos National Laboratory, 2022. Monte Carlo Methods, Codes, & Applications Group, https:\/\/mcnp.lanl.gov\/."},{"key":"10.1016\/j.ejmp.2026.107189_b0100","unstructured":"Pelowitz, D., 2013. MCNP6 User\u2019s Manual Version 1.0. Radiation Safety Information Computational Center, Los Alamos, NM."},{"key":"10.1016\/j.ejmp.2026.107189_b0105","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1016\/j.brachy.2014.07.004","article-title":"A medical image-based graphical platform\u2014Features, applications and relevance for brachytherapy","volume":"13","author":"Fonseca","year":"2014","journal-title":"Brachytherapy"},{"key":"10.1016\/j.ejmp.2026.107189_b0110","doi-asserted-by":"crossref","unstructured":"Beaulieu, L., Tedgren, \u00c5.C., Carrier, J.-F., Davis, S.D., Mourtada, F., Rivard, M.J., et al., 2012. Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation (Task Group No. 186). Med Phys 39, 28.","DOI":"10.1118\/1.4747264"},{"key":"10.1016\/j.ejmp.2026.107189_b0115","unstructured":"Rogers, D., Bazalova-Carter, M., Bolch, W., Heath, E., McNitt-Gray, M., Sempau, J., et al., 2018. RECORDS: improved Reporting of montE CarlO RaDiation transport Studies: Report of the AAPM Research Committee Task Group 268. AAPM-American Association of Physics in Medicine, https:\/\/www.aapm.org\/pubs\/reports\/detail.asp?docid=168, p. 5."},{"key":"10.1016\/j.ejmp.2026.107189_b0120","unstructured":"Helene, O.A.M., Vanin, V.R., 1991. Statistical treatment of data in experimental physics. Blucher, S\u00e3o Paulo."},{"key":"10.1016\/j.ejmp.2026.107189_b0125","unstructured":"Vuolo, J.H., 1996. Error Theory Fundaments, 2nd ed. Edgard Bl\u00fccher, S\u00e3o Paulo."},{"key":"10.1016\/j.ejmp.2026.107189_b0130","unstructured":"RSD, 2022. The Alderson Radiation Therapy Phantom, http:\/\/www.rsdphantoms.com\/pages\/aldersonradiationphantom.html."},{"key":"10.1016\/j.ejmp.2026.107189_b0135","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1088\/0031-9155\/26\/1\/013","article-title":"The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities","volume":"26","author":"Shrimpton","year":"1981","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.107189_b0140","unstructured":"International Commission on Radiological Protection, 2007. ICRP Publication 103: The 2007 Recommendations of the International Commission on Radiological Protection https:\/\/www.icrp.org\/docs\/icrp_publication_103-annals_of_the_icrp_37(2-4)-free_extract.pdf."},{"key":"10.1016\/j.ejmp.2026.107189_b0145","series-title":"Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2","author":"National Research Council","year":"2006"},{"key":"10.1016\/j.ejmp.2026.107189_b0150","unstructured":"Bushong, S.C., 2016. Radiologic Science for Technologists: Physics, Biology, and Protection, 11th ed. Mosby, Elsevier, Maryland Heights, Missouri, USA."},{"key":"10.1016\/j.ejmp.2026.107189_b0155","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1177\/0146645316634566","article-title":"Use of effective dose","volume":"45","author":"Harrison","year":"2016","journal-title":"Ann ICRP"},{"key":"10.1016\/j.ejmp.2026.107189_b0160","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1667\/RR0763.1","article-title":"Solid cancer incidence in atomic bomb survivors: 1958-1998","volume":"168","author":"Preston","year":"2007","journal-title":"Radiat Res"},{"key":"10.1016\/j.ejmp.2026.107189_b0165","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1515\/raon-2016-0019","article-title":"Effect of photon energy spectrum on dosimetric parameters of brachytherapy sources","volume":"50","author":"Ghorbani","year":"2016","journal-title":"Radiol Oncol"},{"key":"10.1016\/j.ejmp.2026.107189_b0170","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1016\/0360-3016(90)90458-V","article-title":"Measurement of dose rate from exposure-calibrated 125I seeds","volume":"18","author":"Luxton","year":"1990","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2026.107189_b0175","unstructured":"United Nations Scientific Committee, 2001. Sources and Effects of Ionizing Radiation. United Nations Scientific Committee on the Effects of Atomic Radiation, https:\/\/www.unscear.org\/."},{"key":"10.1016\/j.ejmp.2026.107189_b0180","doi-asserted-by":"crossref","unstructured":"Lin, E.C., 2010. Radiation risk from medical imaging. Mayo Clinic Proceedings 85, 1142-1146.","DOI":"10.4065\/mcp.2010.0260"},{"key":"10.1016\/j.ejmp.2026.107189_b0185","unstructured":"United Nations Scientific Committee on the Effects of Atomic Radiation, 2017. UNSCEAR\u2019S Global Survey of Radiation Exposure: Medical Exposure, https:\/\/survey.unscear.org\/lib\/exe\/fetch.php?media=unscear_medical_exposure_survey_manual_v2.pdf."},{"key":"10.1016\/j.ejmp.2026.107189_b0190","doi-asserted-by":"crossref","unstructured":"Leyton, F., Canevaro, L., Dourado, A., Castello, H., Bacelar, A., Navarro, M.T., Va\u00f1\u00f3, E., et al., 2014. Riscos da radia\u00e7\u00e3o X e a import\u00e2ncia da prote\u00e7\u00e3o radiol\u00f3gica na cardiologia intervencionista: uma revis\u00e3o sistem\u00e1tica. Revista Brasileira de Cardiologia Invasiva 22, 87-98.","DOI":"10.1590\/0104-1843000000015"},{"key":"10.1016\/j.ejmp.2026.107189_b0195","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1111\/j.1540-8175.2011.01433.x","article-title":"Risk of low-level ionizing radiation from medical imaging procedures","volume":"28","author":"Kerut","year":"2011","journal-title":"Echocardiography"},{"key":"10.1016\/j.ejmp.2026.107189_b0200","unstructured":"Instituto Nacional do Cancer, 2023. Estimativa 2023: Incid\u00eancia de c\u00e2ncer no Brasil. Inca, Rio de Janeiro."}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726002279?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726002279?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T02:54:37Z","timestamp":1791860077000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179726002279"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":40,"alternative-id":["S1120179726002279"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.107189","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Dosimetry with LIF:Mg,Ti (TLD-100) for locating non-paubable breast cancer using Iodine-125 seeds","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.107189","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"107189"}}