{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T03:44:52Z","timestamp":1791863092377,"version":"4.3.4"},"reference-count":24,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100011676","name":"Elekta AB","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100011676","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000009","name":"Foundation for the National Institutes of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000009","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","physicamedica.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Physica Medica"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.ejmp.2026.107194","type":"journal-article","created":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T19:49:52Z","timestamp":1790365792000},"page":"107194","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Introduce the first SPArc optimization algorithm for synchrotron accelerator based proton therapy system"],"prefix":"10.1016","volume":"150","author":[{"given":"Xiaoda","family":"Cong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0439-2075","authenticated-orcid":false,"given":"Jiajian","family":"Shen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1050-3184","authenticated-orcid":false,"given":"Lewei","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peilin","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1733-6278","authenticated-orcid":false,"given":"Xuanfeng","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejmp.2026.107194_b0005","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/j.ijrobp.2016.08.049","article-title":"Spot-scanning proton arc (SPArc) therapy: the first robust and delivery-efficient spot-scanning proton arc therapy","volume":"96","author":"Ding","year":"2016","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2026.107194_b0010","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.radonc.2019.04.032","article-title":"The first prototype of spot-scanning proton arc treatment delivery","volume":"137","author":"Li","year":"2019","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ejmp.2026.107194_b0015","doi-asserted-by":"crossref","first-page":"3067","DOI":"10.1002\/mp.16879","article-title":"Development of a standalone delivery sequence model for proton arc therapy","volume":"51","author":"Liu","year":"2024","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.107194_b0020","first-page":"S187","article-title":"A novel linear energy transfer integrated spot-scanning proton arc therapy algorithm: feasibility study and clinical potential","volume":"108","author":"Li","year":"2020","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2026.107194_b0025","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1186\/s13014-016-0717-4","article-title":"A treatment planning study of proton arc therapy for para-aortic lymph node tumors: dosimetric evaluation of conventional proton therapy, proton arc therapy, and intensity modulated radiotherapy","volume":"11","author":"Rah","year":"2016","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.ejmp.2026.107194_b0030","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/s13014-018-0981-6","article-title":"Improve dosimetric outcome in stage III non-small-cell lung cancer treatment using spot-scanning proton arc (SPArc) therapy","volume":"13","author":"Li","year":"2018","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.ejmp.2026.107194_b0035","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1080\/0284186X.2019.1639823","article-title":"Towards proton arc therapy: physical and biologically equivalent doses with increasing number of beams in pediatric brain irradiation","volume":"58","author":"Toussaint","year":"2019","journal-title":"Acta Oncol"},{"key":"10.1016\/j.ejmp.2026.107194_b0040","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s13014-020-1476-9","article-title":"Improve the dosimetric outcome in bilateral head and neck cancer (HNC) treatment using spot-scanning proton arc (SPArc) therapy: a feasibility study","volume":"15","author":"Liu","year":"2020","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.ejmp.2026.107194_b0045","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1186\/s13014-020-01676-3","article-title":"Feasibility study: spot-scanning proton arc therapy (SPArc) for left-sided whole breast radiotherapy","volume":"15","author":"Chang","year":"2020","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.ejmp.2026.107194_b0050","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1080\/0284186X.2017.1358463","article-title":"Have we reached proton beam therapy dosimetric limitations? \u2013 a novel robust, delivery-efficient and continuous spot-scanning proton arc (SPArc) therapy is to improve the dosimetric outcome in treating prostate cancer","volume":"57","author":"Ding","year":"2018","journal-title":"Acta Oncol"},{"key":"10.1016\/j.ejmp.2026.107194_b0055","unstructured":"Particle Arc Therapy: from concept to clinical reality. https:\/\/www.estro.org\/Workshops\/2022-Physics-Workshop\/Particle-Arc-Therapy-from-concept-to-clinical-real."},{"key":"10.1016\/j.ejmp.2026.107194_b0060","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1080\/0284186X.2023.2172689","article-title":"The first direct method of spot sparsity optimization for proton arc therapy","volume":"62","author":"Zhao","year":"2023","journal-title":"Acta Oncol"},{"key":"10.1016\/j.ejmp.2026.107194_b0065","unstructured":"Fan, Q. et al. Optimizing spot-scanning proton arc therapy with a novel spot sparsity approach. Med Phys n\/a,."},{"key":"10.1016\/j.ejmp.2026.107194_b0070","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.14526","article-title":"Explore the feasibility of using spot-scanning proton arc therapy for a synchrotron accelerator-based proton therapy system \u2013 a simulation study","volume":"26","author":"Cong","year":"2025","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ejmp.2026.107194_b0075","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1016\/j.ijrobp.2008.02.033","article-title":"Comparison between in-beam and offline positron emission tomography imaging of proton and carbon ion therapeutic irradiation at synchrotron- and cyclotron-based facilities","volume":"71","author":"Parodi","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2026.107194_b0080","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ijrobp.2006.01.027","article-title":"Intensity-modulated radiation therapy, protons, and the risk of second cancers","volume":"65","author":"Hall","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ejmp.2026.107194_b0085","unstructured":"NAPT. https:\/\/www.napt.org\/."},{"key":"10.1016\/j.ejmp.2026.107194_b0090","first-page":"421","article-title":"On control and control theory","volume":"14","author":"Manzini","year":"1983","journal-title":"Ling Inq"},{"key":"10.1016\/j.ejmp.2026.107194_b0095","doi-asserted-by":"crossref","first-page":"5081","DOI":"10.1002\/mp.12504","article-title":"Technical note: using experimentally determined proton spot scanning timing parameters to accurately model beam delivery time","volume":"44","author":"Shen","year":"2017","journal-title":"Med Phys"},{"key":"10.1016\/j.ejmp.2026.107194_b0100","series-title":"Principles of optimal control theory","author":"Gamkrelidze","year":"2013"},{"key":"10.1016\/j.ejmp.2026.107194_b0105","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/j.adro.2018.02.006","article-title":"Multiple energy extraction reduces beam delivery time for a synchrotron-based proton spot-scanning system","volume":"3","author":"Younkin","year":"2018","journal-title":"Adv Radiat Oncol"},{"key":"10.1016\/j.ejmp.2026.107194_b0110","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ac8410","article-title":"Investigation of beam delivery time for synchrotron-based proton pencil beam scanning system with novel scanning mode","volume":"67","author":"Liang","year":"2022","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.107194_b0115","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ac8411","article-title":"An evolutionary optimization algorithm for proton arc therapy","volume":"67","author":"Zhao","year":"2022","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ejmp.2026.107194_b0120","doi-asserted-by":"crossref","first-page":"2450","DOI":"10.1002\/mp.14115","article-title":"Development of an isocentric rotating chair positioner to treat patients of head and neck cancer at upright seated position with multiple nonplanar fields in a fixed carbon-ion beamline","volume":"47","author":"Zhang","year":"2020","journal-title":"Med Phys"}],"container-title":["Physica Medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726002322?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1120179726002322?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T02:50:50Z","timestamp":1791859850000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1120179726002322"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":24,"alternative-id":["S1120179726002322"],"URL":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.107194","relation":{},"ISSN":["1120-1797"],"issn-type":[{"value":"1120-1797","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Introduce the first SPArc optimization algorithm for synchrotron accelerator based proton therapy system","name":"articletitle","label":"Article Title"},{"value":"Physica Medica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejmp.2026.107194","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Associazione Italiana di Fisica Medica e Sanitaria. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"107194"}}