{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T08:41:37Z","timestamp":1780735297555,"version":"3.54.1"},"reference-count":15,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2009,4,1]],"date-time":"2009-04-01T00:00:00Z","timestamp":1238544000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["European Journal of Radiology"],"published-print":{"date-parts":[[2009,4]]},"DOI":"10.1016\/j.ejrad.2008.01.006","type":"journal-article","created":{"date-parts":[[2008,2,22]],"date-time":"2008-02-22T16:56:41Z","timestamp":1203699401000},"page":"57-60","source":"Crossref","is-referenced-by-count":64,"title":["CT-guided cutting needle lung biopsy using modified coaxial technique: Factors effecting risk of complications"],"prefix":"10.1016","volume":"70","author":[{"given":"Erkan","family":"Yildirim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ismail","family":"Kirbas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Harman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Umut","family":"Ozyer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H. Gurkan","family":"Tore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cuneyt","family":"Aytekin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fatih","family":"Boyvat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.ejrad.2008.01.006_bib1","doi-asserted-by":"crossref","first-page":"239","DOI":"10.2214\/ajr.175.1.1750239","article-title":"Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules","volume":"175","author":"Tsukada","year":"2000","journal-title":"AJR Am J Roentgenol"},{"issue":"11","key":"10.1016\/j.ejrad.2008.01.006_bib2","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1016\/S1051-0443(07)61556-5","article-title":"Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions","volume":"12","author":"Yeow","year":"2001","journal-title":"J Vasc Interv Radiol"},{"issue":"4","key":"10.1016\/j.ejrad.2008.01.006_bib3","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1007\/s002700010067","article-title":"Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique","volume":"23","author":"Laurent","year":"2000","journal-title":"Cardiovasc Interv Radiol"},{"issue":"5","key":"10.1016\/j.ejrad.2008.01.006_bib4","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1097\/01.RVI.0000071087.76348.C7","article-title":"Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures","volume":"14","author":"Yeow","year":"2003","journal-title":"J Vasc Interv Radiol"},{"issue":"4","key":"10.1016\/j.ejrad.2008.01.006_bib5","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1053\/crad.1999.0368","article-title":"CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20mm: results with an automated 20-gauge coaxial cutting needle","volume":"55","author":"Laurent","year":"2000","journal-title":"Clin Radiol"},{"issue":"2","key":"10.1016\/j.ejrad.2008.01.006_bib6","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1148\/radiology.186.2.8421758","article-title":"Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value","volume":"186","author":"Moulton","year":"1993","journal-title":"Radiology"},{"issue":"3","key":"10.1016\/j.ejrad.2008.01.006_bib7","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1148\/radiology.169.3.3055026","article-title":"Percutaneous transthoracic needle biopsy","volume":"169","author":"Westcott","year":"1988","journal-title":"Radiology"},{"issue":"4","key":"10.1016\/j.ejrad.2008.01.006_bib8","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.2214\/ajr.172.4.10587145","article-title":"Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors","volume":"172","author":"Laurent","year":"1999","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"10.1016\/j.ejrad.2008.01.006_bib9","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1148\/radiology.218.2.r01fe33491","article-title":"Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?","volume":"218","author":"Ko","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.ejrad.2008.01.006_bib10","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1148\/radiology.212.1.r99jl33165","article-title":"Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax","volume":"212","author":"Cox","year":"1999","journal-title":"Radiology"},{"issue":"2","key":"10.1016\/j.ejrad.2008.01.006_bib11","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1148\/radiology.198.2.8596834","article-title":"Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung","volume":"198","author":"Kazerooni","year":"1996","journal-title":"Radiology"},{"issue":"4","key":"10.1016\/j.ejrad.2008.01.006_bib12","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1055\/s-2008-1056580","article-title":"Risk factors in percutaneous transthoracic needle biopsy","volume":"132","author":"Sinner","year":"1980","journal-title":"Rofo"},{"issue":"3","key":"10.1016\/j.ejrad.2008.01.006_bib13","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/S0720-048X(03)00058-5","article-title":"Transthoracic needle biopsy: factors effecting risk of pneumothorax","volume":"48","author":"Topal","year":"2003","journal-title":"Eur J Radiol"},{"issue":"6","key":"10.1016\/j.ejrad.2008.01.006_bib14","doi-asserted-by":"crossref","first-page":"1665","DOI":"10.2214\/ajr.180.6.1801665","article-title":"CT-guided transthoracic needle aspiration biopsy of small (\u226420mm) solitary pulmonary nodules","volume":"180","author":"Ohno","year":"2003","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"10.1016\/j.ejrad.2008.01.006_bib15","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1378\/chest.126.3.748","article-title":"Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies","volume":"126","author":"Yeow","year":"2004","journal-title":"Chest"}],"container-title":["European Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X08000077?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X08000077?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,12,31]],"date-time":"2018-12-31T14:20:25Z","timestamp":1546266025000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0720048X08000077"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,4]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,4]]}},"alternative-id":["S0720048X08000077"],"URL":"https:\/\/doi.org\/10.1016\/j.ejrad.2008.01.006","relation":{},"ISSN":["0720-048X"],"issn-type":[{"value":"0720-048X","type":"print"}],"subject":[],"published":{"date-parts":[[2009,4]]}}}