{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T01:02:09Z","timestamp":1778202129886,"version":"3.51.4"},"reference-count":23,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2014,1,1]],"date-time":"2014-01-01T00:00:00Z","timestamp":1388534400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["ejradiology.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Radiology"],"published-print":{"date-parts":[[2014,1]]},"DOI":"10.1016\/j.ejrad.2013.10.002","type":"journal-article","created":{"date-parts":[[2013,10,16]],"date-time":"2013-10-16T15:31:06Z","timestamp":1381937466000},"page":"e67-e71","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":29,"title":["How does arm positioning of polytraumatized patients in the initial computed tomography (CT) affect image quality and diagnostic accuracy?"],"prefix":"10.1016","volume":"83","author":[{"given":"Johannes","family":"Kahn","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ulrich","family":"Grupp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Maurer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"9673","key":"10.1016\/j.ejrad.2013.10.002_bib0005","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1016\/S0140-6736(09)60232-4","article-title":"Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study","volume":"373","author":"Huber-Wagner","year":"2009","journal-title":"Lancet"},{"issue":"Suppl. 4","key":"10.1016\/j.ejrad.2013.10.002_bib0010","doi-asserted-by":"crossref","first-page":"D105","DOI":"10.1007\/s10406-005-0122-9","article-title":"The trauma concept: the role of MDCT in the diagnosis and management of visceral injuries","volume":"15","author":"Becker","year":"2005","journal-title":"Eur Radiol"},{"issue":"3","key":"10.1016\/j.ejrad.2013.10.002_bib0015","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1097\/TA.0b013e31817de3f4","article-title":"Whole-body multislice computed tomography as the first line diagnostic tool in patients with multiple injuries: the focus on time","volume":"66","author":"Wurmb","year":"2009","journal-title":"J Trauma"},{"issue":"3","key":"10.1016\/j.ejrad.2013.10.002_bib0020","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/j.ejrad.2008.08.014","article-title":"The utilization of dual source CT in imaging of polytrauma","volume":"68","author":"Nicolaou","year":"2008","journal-title":"Eur J Radiol"},{"issue":"12","key":"10.1016\/j.ejrad.2013.10.002_bib0025","doi-asserted-by":"crossref","first-page":"1641","DOI":"10.1055\/s-2005-858790","article-title":"Whole-body MSCT of patients after polytrauma: abdominal injuries","volume":"177","author":"R\u00f6hrl","year":"2005","journal-title":"Rofo"},{"issue":"1","key":"10.1016\/j.ejrad.2013.10.002_bib0030","doi-asserted-by":"crossref","first-page":"3","DOI":"10.2214\/AJR.07.3702","article-title":"Evaluation of a single-pass continuous whole-body 16-MDCT protocol for patients with polytrauma","volume":"192","author":"Nguyen","year":"2009","journal-title":"Am J Roentgenol"},{"issue":"5","key":"10.1016\/j.ejrad.2013.10.002_bib0035","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s10140-006-0554-0","article-title":"Whole body 16-row multislice CT in emergency room: effects of different protocols on scanning time, image quality and radiation exposure","volume":"13","author":"Fanucci","year":"2007","journal-title":"Emerg Radiol"},{"issue":"1","key":"10.1016\/j.ejrad.2013.10.002_bib0040","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.injury.2011.10.014","article-title":"Radiation exposure in whole-body computed tomography of multiple trauma patients: bearing devices and patient positioning","volume":"43","author":"Loewenhardt","year":"2012","journal-title":"Injury"},{"issue":"3","key":"10.1016\/j.ejrad.2013.10.002_bib0045","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1148\/radiol.2293021651","article-title":"Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: initial experience","volume":"229","author":"Ptak","year":"2003","journal-title":"Radiology"},{"issue":"4","key":"10.1016\/j.ejrad.2013.10.002_bib0050","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1007\/s10140-011-0948-5","article-title":"Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality","volume":"18","author":"Karlo","year":"2011","journal-title":"Emerg Radiol"},{"issue":"3","key":"10.1016\/j.ejrad.2013.10.002_bib0055","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s10140-006-0490-z","article-title":"A novel multiple-trauma CT-scanning protocol using patient repositioning","volume":"13","author":"Hoppe","year":"2006","journal-title":"Emerg Radiol"},{"issue":"4","key":"10.1016\/j.ejrad.2013.10.002_bib0060","doi-asserted-by":"crossref","first-page":"900","DOI":"10.1097\/TA.0b013e3181edc80e","article-title":"Influence of arm positioning on radiation dose for whole body computed tomography in trauma patients","volume":"70","author":"Bayer","year":"2011","journal-title":"J Trauma"},{"issue":"9","key":"10.1016\/j.ejrad.2013.10.002_bib0065","doi-asserted-by":"crossref","first-page":"1630","DOI":"10.1007\/s003300050601","article-title":"Standardized CT examination of the multitraumatized patient","volume":"8","author":"Leidner","year":"1998","journal-title":"Eur Radiol"},{"issue":"2","key":"10.1016\/j.ejrad.2013.10.002_bib0070","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1148\/radiol.2492080169","article-title":"Arm raising at exposure-controlled multidetector trauma CT of thoracoabdominal region: higher image quality, lower radiation dose","volume":"249","author":"Brink","year":"2008","journal-title":"Radiology"},{"issue":"3","key":"10.1016\/j.ejrad.2013.10.002_bib0075","doi-asserted-by":"crossref","first-page":"673","DOI":"10.2214\/AJR.04.1513","article-title":"Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis","volume":"186","author":"Rizzo","year":"2006","journal-title":"Am J Roentgenol"},{"issue":"2","key":"10.1016\/j.ejrad.2013.10.002_bib0080","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1148\/rg.262055138","article-title":"CT dose reduction and dose management tools: overview of available options","volume":"26","author":"McCollough","year":"2006","journal-title":"Radiographics"},{"issue":"7","key":"10.1016\/j.ejrad.2013.10.002_bib0085","doi-asserted-by":"crossref","first-page":"1728","DOI":"10.1007\/s00330-001-1225-x","article-title":"Whole-body computed tomography in polytrauma: techniques and management","volume":"12","author":"Linsenmaier","year":"2002","journal-title":"Eur Radiol"},{"issue":"4","key":"10.1016\/j.ejrad.2013.10.002_bib0090","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/0020-1383(94)90073-6","article-title":"The golden hour and prehospital trauma care","volume":"25","author":"McNicholl","year":"1994","journal-title":"Injury"},{"key":"10.1016\/j.ejrad.2013.10.002_bib0095","article-title":"The golden hour of shock \u2013 how time is running out: prehospital time intervals in Germany \u2013 a multivariate analysis of 15, 103 patients from the TraumaRegister DGU\u00ae","author":"Wyen","year":"2012","journal-title":"Emerg Med J"},{"issue":"5","key":"10.1016\/j.ejrad.2013.10.002_bib0100","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1007\/PL00011915","article-title":"Experience with a continuous, single-pass whole-body multidetector CT protocol for trauma: the three-minute multiple trauma CT scan","volume":"8","author":"Ptak","year":"2001","journal-title":"Emerg Radiol"},{"issue":"2","key":"10.1016\/j.ejrad.2013.10.002_bib0105","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1055\/s-2004-813872","article-title":"Prospective randomized trial of a modified standard multislice CT protocol for the evaluation of multiple trauma patients","volume":"177","author":"Heyer","year":"2005","journal-title":"Rofo"},{"issue":"5","key":"10.1016\/j.ejrad.2013.10.002_bib0110","doi-asserted-by":"crossref","first-page":"e63217","DOI":"10.1371\/journal.pone.0063217","article-title":"Population trends and variation in body mass index from 1971 to 2008 in the framingham heart study offspring cohort","volume":"8","author":"Block","year":"2013","journal-title":"PLoS ONE"},{"issue":"6","key":"10.1016\/j.ejrad.2013.10.002_bib0115","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1007\/s10140-007-0577-1","article-title":"A novel multiple-trauma CT-scanning protocol using patient repositioning may increase risks of iatrogenic injuries","volume":"13","author":"Benneker","year":"2007","journal-title":"Emerg Radiol"}],"container-title":["European Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X13005317?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X13005317?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,10,12]],"date-time":"2018-10-12T00:25:18Z","timestamp":1539303918000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0720048X13005317"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,1]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,1]]}},"alternative-id":["S0720048X13005317"],"URL":"https:\/\/doi.org\/10.1016\/j.ejrad.2013.10.002","relation":{},"ISSN":["0720-048X"],"issn-type":[{"value":"0720-048X","type":"print"}],"subject":[],"published":{"date-parts":[[2014,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"How does arm positioning of polytraumatized patients in the initial computed tomography (CT) affect image quality and diagnostic accuracy?","name":"articletitle","label":"Article Title"},{"value":"European Journal of Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejrad.2013.10.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Elsevier Ireland Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}