{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T22:06:27Z","timestamp":1790633187464,"version":"4.1.0"},"reference-count":25,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,2,1]],"date-time":"2018-02-01T00:00:00Z","timestamp":1517443200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["ejradiology.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Radiology"],"published-print":{"date-parts":[[2018,2]]},"DOI":"10.1016\/j.ejrad.2017.12.024","type":"journal-article","created":{"date-parts":[[2017,12,30]],"date-time":"2017-12-30T02:41:32Z","timestamp":1514601692000},"page":"111-117","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":50,"special_numbering":"C","title":["Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: Effects on image quality, artefacts and diagnostic performance for the detection of stenosis"],"prefix":"10.1016","volume":"99","author":[{"given":"Doris","family":"Leithner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scherwin","family":"Mahmoudi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian L.","family":"Wichmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon S.","family":"Martin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lukas","family":"Lenga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moritz H.","family":"Albrecht","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Booz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christophe T.","family":"Arendt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Beeres","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tommaso","family":"D'Angelo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boris","family":"Bodelle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas J.","family":"Vogl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan-Erik","family":"Scholtz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejrad.2017.12.024_bib0005","doi-asserted-by":"crossref","first-page":"2559","DOI":"10.1161\/hs1101.098524","article-title":"Risk factors, outcome, and treatment in subtypes of ischemic stroke: the German stroke data bank","volume":"32","author":"Grau","year":"2001","journal-title":"Stroke"},{"key":"10.1016\/j.ejrad.2017.12.024_bib0010","first-page":"1058","article-title":"The effect of carotid siphon stenosis on stroke rate, death, and relief of symptoms following elective carotid endarterectomy","volume":"92","author":"Schuler","year":"1982","journal-title":"Surgery"},{"key":"10.1016\/j.ejrad.2017.12.024_bib0015","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3310\/hta10300","article-title":"Accurate, practical and cost-effective assessment of carotid stenosis in the UK","volume":"10","author":"Wardlaw","year":"2006","journal-title":"Health Technol. Assess."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0020","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1148\/radiol.10090908","article-title":"Intravenous contrast medium administration and scan timing at CT: considerations and approaches","volume":"256","author":"Bae","year":"2010","journal-title":"Radiology"},{"key":"10.1016\/j.ejrad.2017.12.024_bib0025","doi-asserted-by":"crossref","first-page":"S9","DOI":"10.2214\/AJR.12.9121","article-title":"Dual-energy CT-based monochromatic imaging","volume":"199","author":"Yu","year":"2012","journal-title":"AJR Am. J. Roentgenol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0030","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.acra.2013.12.006","article-title":"Optimization of kiloelectron volt settings in cerebral and cervical dual-energy CT angiography determined with virtual monoenergetic imaging","volume":"21","author":"Schneider","year":"2014","journal-title":"Acad. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0035","doi-asserted-by":"crossref","first-page":"143","DOI":"10.3174\/ajnr.A4502","article-title":"Advanced modeled iterative reconstruction in low-tube-voltage contrast-enhanced neck CT: evaluation of objective and subjective image quality","volume":"37","author":"Scholtz","year":"2016","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0040","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/B978-0-444-53485-9.00001-5","article-title":"Computed tomography imaging and angiography \u2013 principles","volume":"135","author":"Kamalian","year":"2016","journal-title":"Handb. Clin. Neurol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0045","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1097\/RLI.0000000000000077","article-title":"Virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in head and neck cancer","volume":"49","author":"Wichmann","year":"2014","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0050","doi-asserted-by":"crossref","first-page":"1994","DOI":"10.3174\/ajnr.A2654","article-title":"Image quality and radiation dose of dual-energy CT of the head and neck compared with a standard 120-kVp acquisition","volume":"32","author":"Tawfik","year":"2011","journal-title":"AJNR. Am. J. Neuroradiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0055","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1016\/j.ejrad.2016.01.015","article-title":"Carotid dual-energy CT angiography: evaluation of low keV calculated monoenergetic datasets by means of a frequency-split approach for noise reduction at low keV levels","volume":"85","author":"Riffel","year":"2016","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0060","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1097\/RLI.0000000000000060","article-title":"Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media","volume":"49","author":"Grant","year":"2014","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0065","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/RLI.0000000000000216","article-title":"Dual-energy computed tomography angiography of the lower extremity runoff: impact of noise-optimized virtual monochromatic imaging on image quality and diagnostic accuracy","volume":"51","author":"Wichmann","year":"2016","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0070","doi-asserted-by":"crossref","first-page":"e574","DOI":"10.1016\/j.ejrad.2013.04.040","article-title":"Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging","volume":"82","author":"Sudarski","year":"2013","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0075","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1007\/s00330-015-3970-2","article-title":"Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast","volume":"26","author":"Albrecht","year":"2016","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0080","first-page":"681","article-title":"Comparison of the ECST, CC, and NASCET grading methods and ultrasound for assessing carotid stenosis","volume":"247","author":"Staikov","year":"2000","journal-title":"Eur. Carotid Surg. Trial. North Am. Symp. Carotid Endarterectomy Trial J. Neurol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0085","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1097\/RLI.0000000000000272","article-title":"Comprehensive comparison of virtual monoenergetic and linearly blended reconstruction techniques in third-generation dual-source dual-energy computed tomography angiography of the thorax and abdomen","volume":"51","author":"Albrecht","year":"2016","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0090","doi-asserted-by":"crossref","first-page":"2139","DOI":"10.1007\/s00330-011-2162-y","article-title":"Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT","volume":"21","author":"Bauer","year":"2011","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0095","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.crad.2014.10.018","article-title":"Non-linear image blending improves visualization of head and neck primary squamous cell carcinoma compared to linear blending in dual-energy CT","volume":"70","author":"Scholtz","year":"2015","journal-title":"Clin. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0100","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1007\/s00330-016-4422-3","article-title":"Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement","volume":"27","author":"Martin","year":"2017","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0105","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1055\/s-0034-1366423","article-title":"Assessment of the hepatic veins in poor contrast conditions using dual energy CT: evaluation of a novel monoenergetic extrapolation software algorithm","volume":"186","author":"Schabel","year":"2014","journal-title":"Rofo"},{"key":"10.1016\/j.ejrad.2017.12.024_bib0110","doi-asserted-by":"crossref","first-page":"1931","DOI":"10.1161\/CIRCULATIONAHA.115.014672","article-title":"Contrast-induced nephropathy","volume":"132","author":"Wichmann","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.ejrad.2017.12.024_bib0115","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/RLI.0000000000000089","article-title":"Differentiation of low-attenuation intracranial hemorrhage and calcification using dual-energy computed tomography in a phantom system","volume":"50","author":"Nute","year":"2015","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.ejrad.2017.12.024_bib0120","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1148\/radiol.10091806","article-title":"Evaluation of dual-energy CT for differentiating intracerebral hemorrhage from iodinated contrast material staining","volume":"257","author":"Gupta","year":"2010","journal-title":"Radiology"},{"key":"10.1016\/j.ejrad.2017.12.024_bib0125","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1007\/s10554-015-0728-5","article-title":"Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging","volume":"32","author":"Beeres","year":"2016","journal-title":"Int. J. Cardiovasc. Imaging"}],"container-title":["European Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X17305466?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X17305466?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,8,24]],"date-time":"2018-08-24T20:54:44Z","timestamp":1535144084000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0720048X17305466"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2]]},"references-count":25,"alternative-id":["S0720048X17305466"],"URL":"https:\/\/doi.org\/10.1016\/j.ejrad.2017.12.024","relation":{},"ISSN":["0720-048X"],"issn-type":[{"value":"0720-048X","type":"print"}],"subject":[],"published":{"date-parts":[[2018,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: Effects on image quality, artefacts and diagnostic performance for the detection of stenosis","name":"articletitle","label":"Article Title"},{"value":"European Journal of Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejrad.2017.12.024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}