{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T04:37:48Z","timestamp":1771303068078,"version":"3.50.1"},"reference-count":34,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,7,1]],"date-time":"2018-07-01T00:00:00Z","timestamp":1530403200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["ejradiology.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Radiology"],"published-print":{"date-parts":[[2018,7]]},"DOI":"10.1016\/j.ejrad.2018.04.018","type":"journal-article","created":{"date-parts":[[2018,4,27]],"date-time":"2018-04-27T13:18:22Z","timestamp":1524835102000},"page":"136-142","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":42,"special_numbering":"C","title":["Artifact reduction from dental implants using virtual monoenergetic reconstructions from novel spectral detector CT"],"prefix":"10.1016","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7928-0487","authenticated-orcid":false,"given":"Nils","family":"Gro\u00dfe Hokamp","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.R.","family":"Laukamp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Lennartz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Zopfs","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Abdullayev","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4687-5956","authenticated-orcid":false,"given":"V.F.","family":"Neuhaus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8942-3776","authenticated-orcid":false,"given":"D.","family":"Maintz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2908-7560","authenticated-orcid":false,"given":"J.","family":"Borggrefe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejrad.2018.04.018_bib0005","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1007\/s00234-015-1537-1","article-title":"Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?","volume":"57","author":"De Crop","year":"2015","journal-title":"Neuroradiology"},{"key":"10.1016\/j.ejrad.2018.04.018_bib0010","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1177\/0284185117692174","article-title":"Dual-energy CT with virtual monochromatic images and metal artifact reduction software for reducing metallic dental artifacts","volume":"58","author":"Cha","year":"2017","journal-title":"Acta Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0015","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.2214\/AJR.09.2610","article-title":"Value of 3D CT in defining skeletal complications of orthopedic hardware in the postoperative patient","volume":"193","author":"Fayad","year":"2009","journal-title":"Am. J. Roentgenol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0020","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1148\/rg.273065087","article-title":"Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT","volume":"27","author":"Lee","year":"2007","journal-title":"Radiographics"},{"key":"10.1016\/j.ejrad.2018.04.018_bib0025","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1007\/s12194-012-0179-9","article-title":"Photon starvation artifacts of X-ray CT: Their true cause and a solution","volume":"6","author":"Mori","year":"2013","journal-title":"Radiol. Phys. Technol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0030","doi-asserted-by":"crossref","first-page":"229","DOI":"10.2217\/iim.12.13","article-title":"CT artifacts: causes and reduction techniques","volume":"4","author":"Boas","year":"2012","journal-title":"Imaging Med."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0035","doi-asserted-by":"crossref","first-page":"2064","DOI":"10.1148\/rg.2016160079","article-title":"Artifacts at cardiac CT: physics and solutions","volume":"36","author":"Kalisz","year":"2016","journal-title":"Radiographics"},{"key":"10.1016\/j.ejrad.2018.04.018_bib0040","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1148\/radiographics.18.2.9536489","article-title":"The AAPM\/RSNA physics tutorial for residents. X-ray interactions","volume":"18","author":"Bushberg","year":"1998","journal-title":"Radiographics"},{"key":"10.1016\/j.ejrad.2018.04.018_bib0045","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20140473","article-title":"Metal artefact reduction in CT imaging of hip prostheses-an evaluation of commercial techniques provided by four vendors","volume":"88","author":"Andersson","year":"2015","journal-title":"Br. J. Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0050","doi-asserted-by":"crossref","first-page":"e11","DOI":"10.1016\/j.crad.2013.08.008","article-title":"Reduction of dental metallic artefacts in CT: value of a newly developed algorithm for metal artefact reduction (O-MAR)","volume":"69","author":"Kidoh","year":"2014","journal-title":"Clin. Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0055","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1007\/s00330-005-2919-2","article-title":"First performance evaluation of a dual-source CT (DSCT) system","volume":"16","author":"Flohr","year":"2006","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0060","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1007\/s00256-012-1458-6","article-title":"Reducing the effects of metal artefact using high keV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements","volume":"42","author":"Lewis","year":"2013","journal-title":"Skeletal Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0065","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.ejrad.2017.01.002","article-title":"Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses","volume":"88","author":"Wellenberg","year":"2017","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0070","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and multi-energy CT: principles, technical approaches, and clinical applications","volume":"276","author":"McCollough","year":"2015","journal-title":"Radiology"},{"key":"10.1016\/j.ejrad.2018.04.018_bib0075","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.2214\/AJR.12.9116","article-title":"Dual-energy CT: general principles","volume":"199","author":"Johnson","year":"2012","journal-title":"AJR Am. J. Roentgenol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0080","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1088\/0031-9155\/21\/5\/002","article-title":"Energy-selective reconstructions in X-ray computerized tomography","volume":"21","author":"Alvarez","year":"1976","journal-title":"Phys. Med. Biol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0085","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.ejrad.2017.05.013","article-title":"Metal artifact reduction by dual-layer computed tomography using virtual monoenergetic images","volume":"93","author":"Neuhaus","year":"2017","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0090","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/s00256-017-2776-5","article-title":"Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms","volume":"47","author":"Gro\u00dfe Hokamp","year":"2018","journal-title":"Skeletal Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0095","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1007\/s40134-012-0006-4","article-title":"State of the art of CT detectors and sources: a literature review","volume":"1","author":"Shefer","year":"2013","journal-title":"Curr. Radiol. Rep."},{"issue":"Jan. (2)","key":"10.1016\/j.ejrad.2018.04.018_bib0100","doi-asserted-by":"crossref","first-page":"025027","DOI":"10.1088\/1361-6560\/aa9e1b","article-title":"Objective image characterization of a spectral CT scanner with dual-layer detector","volume":"63","author":"Ozguner","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0105","doi-asserted-by":"crossref","first-page":"1424","DOI":"10.1007\/s00330-011-2062-1","article-title":"Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation","volume":"21","author":"Bamberg","year":"2011","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0110","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1177\/001316447303300309","article-title":"The equivalence of weighted kappa and the intraclass correlation coefficient as measures of reliability","volume":"33","author":"Fleiss","year":"1973","journal-title":"Educ. Psychol. Meas."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0115","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.1088\/0031-9155\/60\/3\/1047","article-title":"An evaluation of three commercially available metal artifact reduction methods for CT imaging","volume":"60","author":"Huang","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0120","doi-asserted-by":"crossref","DOI":"10.1016\/j.crad.2016.12.006","article-title":"Iterative metal artefact reduction in CT: can dedicated algorithms improve image quality after spinal instrumentation?","volume":"72","author":"Aissa","year":"2017","journal-title":"Clin. Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0125","doi-asserted-by":"crossref","first-page":"e0143584","DOI":"10.1371\/journal.pone.0143584","article-title":"Comparison and combination of dual-energy- and iterative-based metal artefact reduction on hip prosthesis and dental implants","volume":"10","author":"Bongers","year":"2015","journal-title":"PLoS One"},{"issue":"Sep. (9)","key":"10.1016\/j.ejrad.2018.04.018_bib0130","doi-asserted-by":"crossref","first-page":"4463","DOI":"10.1002\/mp.12424","article-title":"Determining the orientation angle of directional leads for deep brain stimulation using computed tomography and digital x-ray imaging: a phantom study","volume":"44","author":"Sitz","year":"2017","journal-title":"Med. Phys."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0135","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1118\/1.596187","article-title":"Correction for scattered radiation and other background signals in dual-energy computed tomography material thickness measurements","volume":"15","author":"Vetter","year":"1988","journal-title":"Med. Phys."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0140","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1118\/1.4905106","article-title":"Dual energy CT: How well can pseudo-monochromatic imaging reduce metal artifacts?","volume":"42","author":"Kuchenbecker","year":"2015","journal-title":"Med. Phys."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0145","doi-asserted-by":"crossref","first-page":"e538","DOI":"10.1016\/j.crad.2014.08.021","article-title":"Comparison of radiation dose and image quality from single-energy and dual-energy CT examinations in the same patients screened for hepatocellular carcinoma","volume":"69","author":"Purysko","year":"2014","journal-title":"Clin. Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0150","doi-asserted-by":"crossref","first-page":"S16","DOI":"10.2214\/AJR.12.9210","article-title":"Dual-energy CT: radiation dose aspects","volume":"199","author":"Henzler","year":"2012","journal-title":"AJR Am. J. Roentgenol."},{"issue":"Feb","key":"10.1016\/j.ejrad.2018.04.018_bib0155","article-title":"Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT","author":"Euler","year":"2018","journal-title":"Eur. Radiol."},{"issue":"Jan","key":"10.1016\/j.ejrad.2018.04.018_bib0160","article-title":"Thoracic-abdominal imaging with a novel dual-layer spectral detector CT: intra-individual comparison of image quality and radiation dose with 128-row single-energy acquisition","author":"Haneder","year":"2018","journal-title":"Acta Radiol."},{"key":"10.1016\/j.ejrad.2018.04.018_bib0165","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1007\/s00586-009-0998-5","article-title":"Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: State of the art","volume":"18","author":"Stradiotti","year":"2009","journal-title":"Eur. Spine J."},{"issue":"Mar","key":"10.1016\/j.ejrad.2018.04.018_bib0170","article-title":"Reduction of artifacts caused by deep brain stimulating electrodes in cranial computed tomography imaging by means of virtual monoenergetic images, metal artifact reduction algorithms, and their combination","author":"Gro\u00dfe Hokamp","year":"2018","journal-title":"Invest. Radiol."}],"container-title":["European Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X1830144X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X1830144X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,7,6]],"date-time":"2018-07-06T22:47:28Z","timestamp":1530917248000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0720048X1830144X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7]]},"references-count":34,"alternative-id":["S0720048X1830144X"],"URL":"https:\/\/doi.org\/10.1016\/j.ejrad.2018.04.018","relation":{},"ISSN":["0720-048X"],"issn-type":[{"value":"0720-048X","type":"print"}],"subject":[],"published":{"date-parts":[[2018,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Artifact reduction from dental implants using virtual monoenergetic reconstructions from novel spectral detector CT","name":"articletitle","label":"Article Title"},{"value":"European Journal of Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejrad.2018.04.018","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}