{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T00:18:05Z","timestamp":1784679485382,"version":"3.55.0"},"reference-count":16,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2019,7,1]],"date-time":"2019-07-01T00:00:00Z","timestamp":1561939200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,7,1]],"date-time":"2019-07-01T00:00:00Z","timestamp":1561939200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"name":"Siemens Healthcare USA"},{"DOI":"10.13039\/501100011699","name":"Siemens Healthineers","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100011699","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","ejradiology.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Radiology"],"published-print":{"date-parts":[[2019,7]]},"DOI":"10.1016\/j.ejrad.2019.04.010","type":"journal-article","created":{"date-parts":[[2019,4,19]],"date-time":"2019-04-19T19:48:01Z","timestamp":1555703281000},"page":"14-20","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"special_numbering":"C","title":["The effect of intraparenchymal blood patching on the rate of pneumothorax in patients undergoing percutaneous CT-guided core biopsy of the lung"],"prefix":"10.1016","volume":"116","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9990-1092","authenticated-orcid":false,"given":"R.M.","family":"Perl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Risse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Hetzel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.","family":"B\u00f6sm\u00fcller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Kloth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Fritz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Horger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.ejrad.2019.04.010_bib0005","doi-asserted-by":"crossref","first-page":"333","DOI":"10.21037\/jtd.2017.02.16","article-title":"CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing","volume":"9","author":"Tian","year":"2017","journal-title":"J. Thorac. Dis."},{"issue":"2","key":"10.1016\/j.ejrad.2019.04.010_bib0010","doi-asserted-by":"crossref","first-page":"210","DOI":"10.3348\/kjr.2012.13.2.210","article-title":"CT-guided percutaneous biopsy of intrathoracic lesions","volume":"13","author":"Lal","year":"2012","journal-title":"Korean J. Radiol."},{"issue":"2","key":"10.1016\/j.ejrad.2019.04.010_bib0015","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1111\/j.1365-2796.2011.02498.x","article-title":"Systems cancer medicine: towards realization of predictive, preventive, personalized and participatory (P4) medicine","volume":"271","author":"Tian","year":"2012","journal-title":"J. Intern. Med."},{"issue":"Suppl. 1","key":"10.1016\/j.ejrad.2019.04.010_bib0020","first-page":"S99","article-title":"Pneumothorax after transthoracic needle biopsy of lung lesions under CT guidance","volume":"6","author":"Boskovic","year":"2014","journal-title":"J. Thorac. Dis."},{"issue":"10","key":"10.1016\/j.ejrad.2019.04.010_bib0025","doi-asserted-by":"crossref","first-page":"3483","DOI":"10.1007\/s00330-015-4200-7","article-title":"Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors","volume":"26","author":"Moreland","year":"2016","journal-title":"Eur. Radiol."},{"issue":"1","key":"10.1016\/j.ejrad.2019.04.010_bib0030","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1007\/s00330-016-4357-8","article-title":"Complication rates of CT-guided transthoracic lung biopsy: meta-analysis","volume":"27","author":"Heerink","year":"2017","journal-title":"Eur. Radiol."},{"issue":"3","key":"10.1016\/j.ejrad.2019.04.010_bib0035","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1378\/chest.126.3.748","article-title":"Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies","volume":"126","author":"Yeow","year":"2004","journal-title":"Chest"},{"issue":"4","key":"10.1016\/j.ejrad.2019.04.010_bib0040","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1016\/j.jvir.2016.12.1217","article-title":"Pulmonary intraparenchymal blood patching decreases the rate of pneumothorax-related complications following percutaneous CT-Guided needle biopsy","volume":"28","author":"Graffy","year":"2017","journal-title":"J. Vasc. Interv. Radiol."},{"issue":"1","key":"10.1016\/j.ejrad.2019.04.010_bib0045","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1148\/radiology.216.1.r00jl3293","article-title":"Autologous blood clot seal to prevent pneumothorax at CT-guided lung biopsy","volume":"216","author":"Lang","year":"2000","journal-title":"Radiology"},{"issue":"1 Pt 1","key":"10.1016\/j.ejrad.2019.04.010_bib0050","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1148\/radiology.166.1.3336708","article-title":"Transthoracic needle aspiration biopsy: evaluation of the blood patch technique","volume":"166","author":"Bourgouin","year":"1988","journal-title":"Radiology"},{"issue":"2","key":"10.1016\/j.ejrad.2019.04.010_bib0055","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1148\/radiology.176.2.2367653","article-title":"Usefulness of the blood patch technique after transthoracic needle aspiration biopsy","volume":"176","author":"Herman","year":"1990","journal-title":"Radiology"},{"issue":"6","key":"10.1016\/j.ejrad.2019.04.010_bib0060","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.2214\/AJR.12.8980","article-title":"Effect of intraparenchymal blood patch on rates of pneumothorax and pneumothorax requiring chest tube placement after percutaneous lung biopsy","volume":"200","author":"Malone","year":"2013","journal-title":"AJR Am. J. Roentgenol."},{"issue":"6","key":"10.1016\/j.ejrad.2019.04.010_bib0065","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1007\/s00270-015-1097-0","article-title":"The effect of needle gauge on the risk of pneumothorax and chest tube placement after percutaneous computed tomographic (CT)-Guided lung biopsy","volume":"38","author":"Kuban","year":"2015","journal-title":"Cardiovasc. Intervent. Radiol."},{"issue":"6","key":"10.1016\/j.ejrad.2019.04.010_bib0070","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1007\/BF00338305","article-title":"Fibrin glue for sealing the needle track in fine-needle percutaneous lung biopsy using a coaxial system: part II--clinical study","volume":"18","author":"Petsas","year":"1995","journal-title":"Cardiovasc. Intervent. Radiol."},{"issue":"6","key":"10.1016\/j.ejrad.2019.04.010_bib0075","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1007\/s00330-008-0872-6","article-title":"CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track","volume":"18","author":"Billich","year":"2008","journal-title":"Eur. Radiol."},{"issue":"2","key":"10.1016\/j.ejrad.2019.04.010_bib0080","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0192920","article-title":"Coaxial technique-promoted diagnostic accuracy of CT-guided percutaneous cutting needle biopsy for small and deep lung lesions","volume":"13","author":"Zhang","year":"2018","journal-title":"PLoS One"}],"container-title":["European Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X19301445?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X19301445?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T07:14:58Z","timestamp":1759994098000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0720048X19301445"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7]]},"references-count":16,"alternative-id":["S0720048X19301445"],"URL":"https:\/\/doi.org\/10.1016\/j.ejrad.2019.04.010","relation":{},"ISSN":["0720-048X"],"issn-type":[{"value":"0720-048X","type":"print"}],"subject":[],"published":{"date-parts":[[2019,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The effect of intraparenchymal blood patching on the rate of pneumothorax in patients undergoing percutaneous CT-guided core biopsy of the lung","name":"articletitle","label":"Article Title"},{"value":"European Journal of Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejrad.2019.04.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}