{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:03:10Z","timestamp":1789689790546,"version":"4.0.1"},"reference-count":31,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T00:00:00Z","timestamp":1723161600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","ejradiology.com","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Radiology"],"published-print":{"date-parts":[[2024,10]]},"DOI":"10.1016\/j.ejrad.2024.111680","type":"journal-article","created":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T22:22:36Z","timestamp":1723242156000},"page":"111680","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":18,"special_numbering":"C","title":["PCD-CT enables contrast media reduction in abdominal imaging compared to an individualized kV-adapted contrast media injection protocol on EID-CT"],"prefix":"10.1016","volume":"179","author":[{"given":"Eva J.I.","family":"Hoeijmakers","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lion","family":"Stammen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joachim E.","family":"Wildberger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nienke G.","family":"Eijsvoogel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johanna M.","family":"Hersbach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joey C.J.G.","family":"Pernot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas G.","family":"Flohr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bibi","family":"Martens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C\u00e9cile R.L.P.N.","family":"Jeukens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"9","key":"10.1016\/j.ejrad.2024.111680_b0005","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1097\/RLI.0000000000000696","article-title":"Developments in X-ray contrast media and the potential impact on computed tomography","volume":"55","author":"Schockel","year":"2020","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.ejrad.2024.111680_b0010","first-page":"1","article-title":"Risk of acute kidney injury following IV iodinated contrast media exposure: 2023 update, from the AJR special series on contrast media","author":"McDonald","year":"2023","journal-title":"AJR Am. J. Roentgenol."},{"issue":"5","key":"10.1016\/j.ejrad.2024.111680_b0015","doi-asserted-by":"crossref","first-page":"1859","DOI":"10.1177\/02841851231151511","article-title":"Revised Swedish guidelines on intravenous iodine contrast medium-induced acute kidney injury 2022: a summary","volume":"64","author":"Nyman","year":"2023","journal-title":"Acta Radiol."},{"key":"10.1016\/j.ejrad.2024.111680_b0020","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/859328","article-title":"Contrast-induced acute kidney injury: definition, epidemiology, and outcome","volume":"2014","author":"Meinel","year":"2014","journal-title":"Biomed Res. Int."},{"issue":"6","key":"10.1016\/j.ejrad.2024.111680_b0025","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/RLI.0000000000000844","article-title":"Individualized scan protocols in abdominal computed tomography: radiation versus contrast media dose optimization","volume":"57","author":"Martens","year":"2022","journal-title":"Invest. Radiol."},{"issue":"5","key":"10.1016\/j.ejrad.2024.111680_b0030","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1097\/RCT.0000000000000106","article-title":"Reduction of iodine load in CT imaging of pancreas acquired with low tube voltage and an adaptive statistical iterative reconstruction technique","volume":"38","author":"Noda","year":"2014","journal-title":"J. Comput. Assist. Tomogr."},{"issue":"10","key":"10.1016\/j.ejrad.2024.111680_b0035","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1097\/RLI.0000000000000682","article-title":"Tailoring contrast media protocols to varying tube voltages in vascular and parenchymal CT imaging: the 10-to-10 rule","volume":"55","author":"Martens","year":"2020","journal-title":"Invest. Radiol."},{"issue":"10","key":"10.1016\/j.ejrad.2024.111680_b0040","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1097\/RLI.0000000000000693","article-title":"A solution for homogeneous liver enhancement in computed tomography: results from the COMpLEx trial","volume":"55","author":"Martens","year":"2020","journal-title":"Invest. Radiol."},{"issue":"1113","key":"10.1016\/j.ejrad.2024.111680_b0045","doi-asserted-by":"crossref","first-page":"20200340","DOI":"10.1259\/bjr.20200340","article-title":"Virtual monoenergetic images preserve diagnostic assessability in contrast media reduced abdominal spectral detector CT","volume":"93","author":"Lennartz","year":"2020","journal-title":"Br. J. Radiol."},{"issue":"6","key":"10.1016\/j.ejrad.2024.111680_b0050","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1097\/RLI.0000000000000643","article-title":"Double low-dose dual-energy liver CT in patients at high-risk of HCC: a prospective, randomized, single-center study","volume":"55","author":"Yoon","year":"2020","journal-title":"Invest. Radiol."},{"issue":"1100","key":"10.1016\/j.ejrad.2024.111680_b0055","doi-asserted-by":"crossref","first-page":"20180414","DOI":"10.1259\/bjr.20180414","article-title":"Iodine load reduction in dual-energy spectral CT portal venography with low energy images combined with adaptive statistical iterative reconstruction","volume":"92","author":"Han","year":"2019","journal-title":"Br. J. Radiol."},{"issue":"7","key":"10.1016\/j.ejrad.2024.111680_b0060","doi-asserted-by":"crossref","first-page":"e0133170","DOI":"10.1371\/journal.pone.0133170","article-title":"Possible contrast media reduction with low keV monoenergetic images in the detection of focal liver lesions: a dual-energy CT animal study","volume":"10","author":"Chung","year":"2015","journal-title":"PLoS One"},{"issue":"10","key":"10.1016\/j.ejrad.2024.111680_b0065","doi-asserted-by":"crossref","first-page":"1915","DOI":"10.1016\/j.ejrad.2015.06.019","article-title":"Monochromatic image reconstruction by dual energy imaging allows half iodine load computed tomography coronary angiography","volume":"84","author":"Carrascosa","year":"2015","journal-title":"Eur. J. Radiol."},{"issue":"7","key":"10.1016\/j.ejrad.2024.111680_b0070","doi-asserted-by":"crossref","first-page":"2894","DOI":"10.1007\/s00261-015-0462-4","article-title":"The initial experience of the upper abdominal CT angiography using low-concentration contrast medium on dual energy spectral CT","volume":"40","author":"Xin","year":"2015","journal-title":"Abdom. Imaging"},{"issue":"2","key":"10.1016\/j.ejrad.2024.111680_b0075","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1148\/radiol.2018172656","article-title":"Photon-counting CT: technical principles and clinical prospects","volume":"289","author":"Willemink","year":"2018","journal-title":"Radiology"},{"key":"10.1016\/j.ejrad.2024.111680_b0080","doi-asserted-by":"crossref","DOI":"10.1097\/RLI.0000000000001078","article-title":"Countering calcium blooming with personalized contrast media injection protocols: the 1-2-3 rule for photon-counting detector CCTA","author":"McDermott","year":"2024","journal-title":"Invest. Radiol."},{"issue":"7","key":"10.1016\/j.ejrad.2024.111680_b0085","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1097\/RLI.0000000000000251","article-title":"Human imaging with photon counting-based computed tomography at clinical dose levels: contrast-to-noise ratio and cadaver studies","volume":"51","author":"Gutjahr","year":"2016","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.ejrad.2024.111680_b0090","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2020.108909","article-title":"Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT","volume":"126","author":"Sawall","year":"2020","journal-title":"Eur. J. Radiol."},{"issue":"24","key":"10.1016\/j.ejrad.2024.111680_b0095","article-title":"An intra-individual comparison of low-keV photon-counting CT versus energy-integrating-detector CT angiography of the aorta","volume":"13","author":"Hennes","year":"2023","journal-title":"Diagnostics (Basel)"},{"issue":"2","key":"10.1016\/j.ejrad.2024.111680_b0100","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1097\/RLI.0000000000000911","article-title":"Reduced Iodinated contrast media administration in coronary CT angiography on a clinical photon-counting detector CT system: a phantom study using a dynamic circulation model","volume":"58","author":"Emrich","year":"2023","journal-title":"Invest. Radiol."},{"issue":"1","key":"10.1016\/j.ejrad.2024.111680_b0105","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.acra.2023.06.025","article-title":"Saving contrast media in coronary CT angiography with photon-counting detector CT","volume":"31","author":"Cundari","year":"2024","journal-title":"Acad. Radiol."},{"issue":"1","key":"10.1016\/j.ejrad.2024.111680_b0110","doi-asserted-by":"crossref","first-page":"e220140","DOI":"10.1148\/ryct.220140","article-title":"CT Angiography of the aorta using photon-counting detector CT with reduced contrast media volume","volume":"5","author":"Higashigaito","year":"2023","journal-title":"Radiol. Cardiothorac. Imaging"},{"issue":"11","key":"10.1016\/j.ejrad.2024.111680_b0115","doi-asserted-by":"crossref","first-page":"7830","DOI":"10.1007\/s00330-023-09777-9","article-title":"Photon-counting CT for diagnosis of acute pulmonary embolism: potential for contrast medium and radiation dose reduction","volume":"33","author":"Pannenbecker","year":"2023","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ejrad.2024.111680_b0120","doi-asserted-by":"crossref","DOI":"10.1097\/RCT.0000000000001617","article-title":"Reduced intravenous contrast dose portal venous phase photon-counting computed tomography compared with conventional energy-integrating detector portal venous phase computed tomography","author":"Dane","year":"2024","journal-title":"J. Comput. Assist. Tomogr."},{"issue":"6","key":"10.1016\/j.ejrad.2024.111680_b0125","doi-asserted-by":"crossref","first-page":"e28142","DOI":"10.1016\/j.heliyon.2024.e28142","article-title":"Image quality of abdominal photon-counting CT with reduced contrast media dose: Evaluation of reduced contrast media protocols during the COVID19 pandemic supply shortage","volume":"10","author":"Layer","year":"2024","journal-title":"Heliyon"},{"key":"10.1016\/j.ejrad.2024.111680_b0130","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2023.111153","article-title":"Reduced versus standard dose contrast volume for contrast-enhanced abdominal CT in overweight and obese patients using photon counting detector technology vs. second-generation dual-source energy integrating detector CT","volume":"169","author":"Hagen","year":"2023","journal-title":"Eur. J. Radiol."},{"issue":"5","key":"10.1016\/j.ejrad.2024.111680_b0135","article-title":"Optimal conspicuity of liver metastases in virtual monochromatic imaging reconstructions on a novel photon-counting detector CT-effect of keV settings and BMI","volume":"12","author":"Bette","year":"2022","journal-title":"Diagnostics (Basel)"},{"issue":"12","key":"10.1016\/j.ejrad.2024.111680_b0140","doi-asserted-by":"crossref","first-page":"8528","DOI":"10.1007\/s00330-023-09876-7","article-title":"Impact of virtual monoenergetic levels on coronary plaque volume components using photon-counting computed tomography","volume":"33","author":"Vattay","year":"2023","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ejrad.2024.111680_b0145","article-title":"International variation in radiation dose for computed tomography examinations: prospective cohort study","volume":"364","author":"Smith-Bindman","year":"2019","journal-title":"BMJ"},{"issue":"5","key":"10.1016\/j.ejrad.2024.111680_b0150","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1016\/j.acra.2022.05.021","article-title":"Radiation dose reduction in contrast-enhanced abdominal CT: comparison of photon-counting detector CT with 2nd generation dual-source dual-energy CT in an oncologic cohort","volume":"30","author":"Wrazidlo","year":"2023","journal-title":"Acad. Radiol."},{"key":"10.1016\/j.ejrad.2024.111680_b0155","doi-asserted-by":"crossref","first-page":"4494","DOI":"10.1007\/s00330-023-10493-7","article-title":"How subjective CT image quality assessment becomes surprisingly reliable: pairwise comparisons instead of Likert scale","volume":"34","author":"Hoeijmakers","year":"2024","journal-title":"Eur. Radiol."}],"container-title":["European Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X24003966?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X24003966?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,8,28]],"date-time":"2024-08-28T12:22:31Z","timestamp":1724847751000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0720048X24003966"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":31,"alternative-id":["S0720048X24003966"],"URL":"https:\/\/doi.org\/10.1016\/j.ejrad.2024.111680","relation":{},"ISSN":["0720-048X"],"issn-type":[{"value":"0720-048X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"PCD-CT enables contrast media reduction in abdominal imaging compared to an individualized kV-adapted contrast media injection protocol on EID-CT","name":"articletitle","label":"Article Title"},{"value":"European Journal of Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejrad.2024.111680","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"111680"}}