{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T01:07:14Z","timestamp":1780103234758,"version":"3.54.0"},"reference-count":31,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","ejradiology.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Radiology"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1016\/j.ejrad.2026.112878","type":"journal-article","created":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T14:52:21Z","timestamp":1776523941000},"page":"112878","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Influence of body size on the accuracy of lumbar bone mineral density by dual-energy CT: A phantom study"],"prefix":"10.1016","volume":"200","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-4571-3164","authenticated-orcid":false,"given":"Narumi","family":"Nonoura","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minoru","family":"Yamada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoki","family":"Nagasawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takenori","family":"Yamashita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiromi","family":"Hisazumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroya","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.ejrad.2026.112878_b0005","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/s11657-012-0109-9","article-title":"Japanese 2011 guidelines for prevention and treatment of osteoporosis\u2013executive summary","volume":"7","author":"Orimo","year":"2012","journal-title":"Arch Osteoporos."},{"key":"10.1016\/j.ejrad.2026.112878_b0010","unstructured":"International Atomic Energy Agency, Dual Energy X Ray Absorptiometry for Bone Mineral Density and Body Composition Assessment, IAEA Human Health Series No. 15, IAEA, Vienna (2011).p.1-30."},{"key":"10.1016\/j.ejrad.2026.112878_b0015","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.trsl.2016.09.006","article-title":"Advances in imaging approaches to fracture risk evaluation","volume":"181","author":"Manhard","year":"2017","journal-title":"Transl Res."},{"key":"10.1016\/j.ejrad.2026.112878_b0020","unstructured":"The International Society For Clinical Densitometry. Official Positions 2015.USA: The International Society For Clinical Densitometry;2015.p.4-14."},{"key":"10.1016\/j.ejrad.2026.112878_b0025","unstructured":"International Atomic Energy Agency, Dual Energy X Ray Absorptiometry for Bone Mineral Density and Body Composition Assessment, IAEA Human Health Series No. 15, IAEA, Vienna (2011).p.45-73."},{"issue":"1","key":"10.1016\/j.ejrad.2026.112878_b0030","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1002\/jbmr.506","article-title":"Simulated increases in body fat and errors in bone mineral density measurements by DXA and QCT","volume":"27","author":"Yu","year":"2012","journal-title":"J Bone Miner Res."},{"issue":"1","key":"10.1016\/j.ejrad.2026.112878_b0035","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.1186\/s12891-022-06076-0","article-title":"The impact of obesity on the accuracy of DXA BMD for DXA-equivalent BMD estimation","volume":"23","author":"Kim","year":"2022","journal-title":"BMC Musculoskelet Disord."},{"issue":"3","key":"10.1016\/j.ejrad.2026.112878_b0040","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and multi-energy CT: principles, technical approaches, and clinical applications","volume":"276","author":"McCollough","year":"2015","journal-title":"Radiology."},{"issue":"5","key":"10.1016\/j.ejrad.2026.112878_b0045","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1148\/rg.2020200038","article-title":"Update on multienergy CT: physics, principles, and applications","volume":"40","author":"Rajiah","year":"2020","journal-title":"Radiographics."},{"issue":"4","key":"10.1016\/j.ejrad.2026.112878_b0050","first-page":"725","article-title":"Projection decomposition via univariate optimization for dual-energy CT","volume":"30","author":"Cong","year":"2022","journal-title":"J Xray Sci Technol."},{"issue":"3","key":"10.1016\/j.ejrad.2026.112878_b0055","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1097\/RCT.0000000000001168","article-title":"Dual-energy computed tomography virtual noncalcium technique in diagnosing osteoporosis: correlation with quantitative computed tomography","volume":"45","author":"Liu","year":"2021","journal-title":"J Comput Assist Tomogr."},{"issue":"1","key":"10.1016\/j.ejrad.2026.112878_b0060","doi-asserted-by":"crossref","first-page":"341","DOI":"10.21037\/qims-20-367","article-title":"In vivo quantification of bone mineral density of lumbar vertebrae using fast kVp switching dual-energy CT: correlation with quantitative computed tomography","volume":"11","author":"Zhou","year":"2021","journal-title":"Quant Imaging Med Surg."},{"issue":"5","key":"10.1016\/j.ejrad.2026.112878_b0065","doi-asserted-by":"crossref","first-page":"3076","DOI":"10.1007\/s00330-021-08323-9","article-title":"Diagnostic accuracy of quantitative dual-energy CT-based volumetric bone mineral density assessment for the prediction of osteoporosis-associated fractures","volume":"32","author":"Gruenewald","year":"2022","journal-title":"Eur Radiol."},{"issue":"3","key":"10.1016\/j.ejrad.2026.112878_b0070","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s00774-013-0447-8","article-title":"Japanese Society for Bone and Mineral Research and Japan Osteoporosis Society Joint Review Committee for the Revision of the Diagnostic Criteria for Primary Osteoporosis. Diagnostic criteria for primary osteoporosis","volume":"31","author":"Soen","year":"2013","journal-title":"J Bone Miner Metab."},{"key":"10.1016\/j.ejrad.2026.112878_b0075","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.ejrad.2017.08.016","article-title":"Image quality of virtual monochromatic images obtained using 320-detector row CT: a phantom study evaluating the effects of iterative reconstruction and body size","volume":"95","author":"Okamura","year":"2017","journal-title":"Eur J Radiol."},{"issue":"10","key":"10.1016\/j.ejrad.2026.112878_b0080","article-title":"A survey of local diagnostic reference levels for the head, thorax, abdomen and pelvis computed tomography in Norway and Canada","volume":"11","author":"Tonkopi","year":"2022","journal-title":"Acta Radiol Open."},{"issue":"5","key":"10.1016\/j.ejrad.2026.112878_b0085","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1213\/ANE.0000000000002864","article-title":"Correlation coefficients: appropriate use and interpretation","volume":"126","author":"Schober","year":"2018","journal-title":"Anesth Analg."},{"key":"10.1016\/j.ejrad.2026.112878_b0090","unstructured":"Horizon-and-Discovery-Effective-Dose.pdf. Available from: https:\/\/www.dexamelbourne.com.au\/wp-content\/uploads\/2017\/04\/ (accessed 22 October 2025)."},{"issue":"6","key":"10.1016\/j.ejrad.2026.112878_b0095","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/j.bone.2005.11.007","article-title":"Comparison of effective dose to children and adults from dual X-ray absorptiometry examinations","volume":"38","author":"Blake","year":"2006","journal-title":"Bone."},{"issue":"1","key":"10.1016\/j.ejrad.2026.112878_b0100","volume":"37","year":"2007","journal-title":"Ann ICRP."},{"issue":"11","key":"10.1016\/j.ejrad.2026.112878_b0105","doi-asserted-by":"crossref","first-page":"2259","DOI":"10.1007\/s00198-022-06462-3","article-title":"Management of osteoporosis in patients with chronic kidney disease","volume":"33","author":"Abdalbary","year":"2022","journal-title":"Osteoporos Int."},{"issue":"3","key":"10.1016\/j.ejrad.2026.112878_b0110","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1007\/s40620-022-01553-0","article-title":"Muscle fat infiltration in chronic kidney disease: a marker related to muscle quality, muscle strength and sarcopenia","volume":"36","author":"Avesani","year":"2023","journal-title":"J Nephrol."},{"issue":"5","key":"10.1016\/j.ejrad.2026.112878_b0115","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.breast.2014.05.023","article-title":"Central European Cooperative Oncology Group (CECOG); Swiss Group for Clinical Cancer Research (SAKK). Bone health in breast cancer patients: a comprehensive statement by CECOG\/SAKK Intergroup","volume":"23","author":"Rordorf","year":"2014","journal-title":"Breast."},{"key":"10.1016\/j.ejrad.2026.112878_b0120","doi-asserted-by":"crossref","DOI":"10.1016\/j.ctrv.2022.102434","article-title":"Rethinking breast cancer follow-up based on individual risk and recurrence management","volume":"109","author":"De Rose","year":"2022","journal-title":"Cancer Treat Rev."},{"issue":"1","key":"10.1016\/j.ejrad.2026.112878_b0130","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/s41747-021-00241-1","article-title":"Accuracy and precision of volumetric bone mineral density assessment using dual-source dual-energy versus quantitative CT: a phantom study","volume":"5","author":"Koch","year":"2021","journal-title":"Eur Radiol Exp."},{"issue":"10","key":"10.1016\/j.ejrad.2026.112878_b0135","doi-asserted-by":"crossref","first-page":"4914","DOI":"10.21037\/qims-22-72","article-title":"Effect of abdominal adipose content on spine phantom bone mineral density measured by rapid kilovoltage-switching dual-energy CT and quantitative CT","volume":"12","author":"Ye","year":"2022","journal-title":"Quant Imaging Med Surg."},{"issue":"6","key":"10.1016\/j.ejrad.2026.112878_b0140","doi-asserted-by":"crossref","first-page":"4041","DOI":"10.21037\/qims-23-1741","article-title":"Optimal scanning parameters of lumbar bone density measured by fast kilovoltage-switching dual-energy computed tomography (DECT)","volume":"14","author":"Yang","year":"2024","journal-title":"Quant Imaging Med Surg."},{"issue":"5","key":"10.1016\/j.ejrad.2026.112878_b0145","doi-asserted-by":"crossref","first-page":"104","DOI":"10.3390\/jimaging10050104","article-title":"Vertebral and femoral bone mineral density (BMD) assessment with dual-energy CT versus DXA scan in postmenopausal females","volume":"10","author":"Stoppino","year":"2024","journal-title":"J Imaging."},{"issue":"1","key":"10.1016\/j.ejrad.2026.112878_b0125","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1186\/s41747-021-00224-2","article-title":"Quantitative benchmarking of iodine imaging for two CT spectral imaging technologies: a phantom study","volume":"5","author":"Harsaker","year":"2021","journal-title":"Eur Radiol Exp."},{"issue":"1","key":"10.1016\/j.ejrad.2026.112878_b0150","doi-asserted-by":"crossref","first-page":"164","DOI":"10.21037\/qims-24-185","volume":"15","author":"Zhang","year":"2025","journal-title":"Quant Imaging Med Surg."},{"issue":"1","key":"10.1016\/j.ejrad.2026.112878_b0155","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/s00330-020-07118-8","article-title":"Accuracy, agreement, and reliability of DECT-derived vBMD measurements: an initial ex vivo study","volume":"31","author":"Qin","year":"2021","journal-title":"European radiology"}],"container-title":["European Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X26002263?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X26002263?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T00:42:54Z","timestamp":1780101774000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0720048X26002263"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":31,"alternative-id":["S0720048X26002263"],"URL":"https:\/\/doi.org\/10.1016\/j.ejrad.2026.112878","relation":{},"ISSN":["0720-048X"],"issn-type":[{"value":"0720-048X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Influence of body size on the accuracy of lumbar bone mineral density by dual-energy CT: A phantom study","name":"articletitle","label":"Article Title"},{"value":"European Journal of Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejrad.2026.112878","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"112878"}}