{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T07:03:50Z","timestamp":1790233430223,"version":"4.1.0"},"reference-count":30,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T00:00:00Z","timestamp":1785456000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","ejradiology.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Radiology"],"published-print":{"date-parts":[[2026,11]]},"DOI":"10.1016\/j.ejrad.2026.113121","type":"journal-article","created":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T15:08:35Z","timestamp":1785510515000},"page":"113121","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Improved detection of endovascular stent fractures with photon counting computed tomography: A phantom study"],"prefix":"10.1016","volume":"204","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-1155-321X","authenticated-orcid":false,"given":"Yiheng","family":"Tan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weihao","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard","family":"Haitsma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Braaksma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Paul P.M.","family":"De Vries","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathias","family":"Prokop","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcel J.W.","family":"Greuter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reinoud P.H.","family":"Bokkers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.ejrad.2026.113121_b0005","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1111\/j.1540-8183.2010.00567.x","article-title":"Stent fracture in the coronary and peripheral arteries","volume":"23","author":"Adlakha","year":"2010","journal-title":"J Intervent Cardiol."},{"issue":"1","key":"10.1016\/j.ejrad.2026.113121_b0010","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1016\/j.jvs.2008.07.005","article-title":"Renal artery pseudoaneurysm caused by a complete stent fracture: a case report","volume":"49","author":"Schuurman","year":"2009","journal-title":"J. Vasc. Surg."},{"issue":"1","key":"10.1016\/j.ejrad.2026.113121_b0015","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.jjcc.2007.11.002","article-title":"Late giant coronary aneurysm associated with a fracture of sirolimus eluting stent: a case report","volume":"51","author":"Okamura","year":"2008","journal-title":"J. Cardiol."},{"issue":"2","key":"10.1016\/j.ejrad.2026.113121_b0020","doi-asserted-by":"crossref","first-page":"e86","DOI":"10.1016\/j.ijcard.2007.11.097","article-title":"Fracture of a sirolimus-eluting stent with migration","volume":"130","author":"Kamura","year":"2008","journal-title":"Int. J. Cardiol."},{"issue":"11","key":"10.1016\/j.ejrad.2026.113121_b0025","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.1016\/j.jcin.2016.02.025","article-title":"Incidence and clinical outcomes ofstentfractures on the basis of 6,555patientsand16,482 drug-eluting stentsfrom 4centers","volume":"9","author":"Kan","year":"2016","journal-title":"JACC Cardiovasc. Interv."},{"issue":"1","key":"10.1016\/j.ejrad.2026.113121_b0030","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1148\/radiol.14130920","article-title":"Detection of broken sutures and metal-ring fractures in AneuRx stent-grafts by using three-dimensional CT angiography after endovascular abdominal aortic aneurysm repair: association with late endoleak development and device migration","volume":"272","author":"Ueda","year":"2014","journal-title":"Radiology"},{"key":"10.1016\/j.ejrad.2026.113121_b0035","doi-asserted-by":"crossref","unstructured":"Karanikola E, Dalainas I, Karaolanis G, Zografos G, Filis K. Duplex ultrasound versus computed tomography for the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Where Do We Stand Now? Int J Angiol Off Publ Int Coll Angiol Inc. 2014;23(3):155-164.","DOI":"10.1055\/s-0034-1387925"},{"issue":"2","key":"10.1016\/j.ejrad.2026.113121_b0040","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/j.ejvs.2023.11.002","article-title":"Editor\u2019s choice \u2013 european society for vascular surgery (ESVS) 2024 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms\u2606","volume":"67","author":"Wanhainen","year":"2024","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"issue":"2","key":"10.1016\/j.ejrad.2026.113121_b0045","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1148\/radiol.2018172656","article-title":"Photon-counting CT: technical principles and clinical prospects","volume":"289","author":"Willemink","year":"2018","journal-title":"Radiology"},{"issue":"22","key":"10.1016\/j.ejrad.2026.113121_b0050","doi-asserted-by":"crossref","first-page":"6709","DOI":"10.1088\/0022-3727\/59\/22\/6709","article-title":"Energy-resolved CT imaging with a photon-counting silicon-strip detector","volume":"59","author":"Persson","year":"2014","journal-title":"Phys. Med. Biol."},{"issue":"7","key":"10.1016\/j.ejrad.2026.113121_b0055","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1097\/RLI.0000000000000251","article-title":"Human imaging with photon counting-based computed tomography at clinical dose levels: contrast-to-noise ratio and cadaver studies","volume":"51","author":"Gutjahr","year":"2016","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.ejrad.2026.113121_b0060","doi-asserted-by":"crossref","first-page":"14806","DOI":"10.1038\/s41598-023-41854-3","article-title":"Photon-counting computed tomography of coronary and peripheral artery stents: a phantom study","volume":"13","author":"Stein","year":"2023","journal-title":"Sci. Rep."},{"issue":"4","key":"10.1016\/j.ejrad.2026.113121_b0065","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1097\/RLI.0000000000000835","article-title":"First in-human results of computed tomography angiography for coronary stent assessment with a spectral photon counting computed tomography","volume":"57","author":"Boccalini","year":"2022","journal-title":"Invest. Radiol."},{"issue":"3","key":"10.1016\/j.ejrad.2026.113121_b0070","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.jcct.2023.02.009","article-title":"First in-vivo coronary stent imaging with clinical ultra high resolution photon-counting CT","volume":"17","author":"Geering","year":"2023","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"10.1016\/j.ejrad.2026.113121_b0075","article-title":"Photon-counting computed tomography for coronary stent imaging: in vitro evaluation of 28 coronary stents","volume":"56(10):653","author":"Petritsch","year":"2021","journal-title":"Invest. Radiol."},{"issue":"6","key":"10.1016\/j.ejrad.2026.113121_b0080","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/j.jcct.2018.10.008","article-title":"Quarter-millimeter spectral coronary stent imaging with photon-counting CT: initial experience","volume":"12","author":"Symons","year":"2018","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"issue":"2","key":"10.1016\/j.ejrad.2026.113121_b0085","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1097\/RLI.0000000000000610","article-title":"Spectral photon-counting computed tomography for coronary stent imaging: evaluation of the potential clinical impact for the delineation of in-stent restenosis","volume":"55","author":"Bratke","year":"2020","journal-title":"Invest. Radiol."},{"issue":"4","key":"10.1016\/j.ejrad.2026.113121_b0090","doi-asserted-by":"crossref","first-page":"2469","DOI":"10.1007\/s00330-022-09283-4","article-title":"Stent imaging on a clinical dual-source photon-counting detector CT system\u2014impact of luminal attenuation and sharp kernels on lumen visibility","volume":"33","author":"Decker","year":"2023","journal-title":"Eur. Radiol."},{"issue":"6","key":"10.1016\/j.ejrad.2026.113121_b0095","doi-asserted-by":"crossref","first-page":"513","DOI":"10.3348\/jksr.2010.63.6.513","article-title":"Risk factors and clinical evaluation of superficial femoral artery stent fracture: prot\u00e9g\u00e9 GPS stent","volume":"63","author":"Lee","year":"2010","journal-title":"J Korean Soc Radiol."},{"issue":"1","key":"10.1016\/j.ejrad.2026.113121_b0100","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1109\/TSMC.1979.4310076","article-title":"A threshold selection method from gray-level histograms","volume":"9","author":"Otsu","year":"1979","journal-title":"IEEE Trans. Syst. Man Cybern."},{"issue":"2","key":"10.1016\/j.ejrad.2026.113121_b0105","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.jacc.2004.11.026","article-title":"Prevalence and clinical impact of stent fractures after femoropopliteal stenting","volume":"45","author":"Scheinert","year":"2005","journal-title":"J. Am. Coll. Cardiol."},{"issue":"21","key":"10.1016\/j.ejrad.2026.113121_b0110","doi-asserted-by":"crossref","first-page":"1924","DOI":"10.1016\/j.jacc.2009.05.075","article-title":"Incidence and predictors of drug-eluting stent fracture in human coronary artery a pathologic analysis","volume":"54","author":"Nakazawa","year":"2009","journal-title":"J. Am. Coll. Cardiol."},{"issue":"4","key":"10.1016\/j.ejrad.2026.113121_b0115","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/j.acra.2008.10.010","article-title":"Detection of stent fractures: a comparison of 64-slice CT, conventional cine-angiography, and intravascular ultrasonography","volume":"16","author":"Pang","year":"2009","journal-title":"Acad. Radiol."},{"issue":"7","key":"10.1016\/j.ejrad.2026.113121_b0120","doi-asserted-by":"crossref","first-page":"4173","DOI":"10.1002\/mp.16415","article-title":"Quantifying lumen diameter in coronary artery stents with high-resolution photon counting detector CT and convolutional neural network denoising","volume":"50","author":"Koons","year":"2023","journal-title":"Med. Phys."},{"key":"10.1016\/j.ejrad.2026.113121_b0125","doi-asserted-by":"crossref","unstructured":"Qin L, Zhou S, Dong H, et al. Improvement of coronary stent visualization using ultra-high-resolution photon-counting detector CT. Eur Radiol. Published online April 27, 2024.","DOI":"10.1007\/s00330-024-10760-1"},{"key":"10.1016\/j.ejrad.2026.113121_b0130","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2023.110983","article-title":"Coronary stent imaging in photon counting computed tomography: optimization of reconstruction kernels in a phantom","volume":"166","author":"Michael","year":"2023","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.ejrad.2026.113121_b0135","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1186\/s13244-022-01196-6","article-title":"Structural failure in bridging stentgrafts for branched endovascular aneurysm repair: a case\u2013control study","volume":"13","author":"Hauck","year":"2022","journal-title":"Insights Imaging."},{"issue":"6","key":"10.1016\/j.ejrad.2026.113121_b0140","doi-asserted-by":"crossref","first-page":"3742","DOI":"10.1007\/s00330-023-10430-8","article-title":"Impact of different metal artifact reduction techniques in photon-counting computed tomography head and neck scans in patients with dental hardware","volume":"34","author":"Pallasch","year":"2024","journal-title":"Eur. Radiol."},{"issue":"6","key":"10.1016\/j.ejrad.2026.113121_b0145","doi-asserted-by":"crossref","DOI":"10.1016\/j.heliyon.2024.e27636","article-title":"Photon counting computed tomography of in-stent-stenosis in a phantom: Optimal virtual monoenergetic imaging in ultra high resolution","volume":"10","author":"Elias Michael","year":"2024","journal-title":"Heliyon"},{"issue":"1","key":"10.1016\/j.ejrad.2026.113121_b0150","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/s00270-024-03874-y","article-title":"In-stent restenosis in peripheral arterial disease: ultra-high-resolution photon-counting versus third-generation dual-source energy-integrating detector CT phantom study in seven different stent types","volume":"48","author":"Dachs","year":"2025","journal-title":"Cardiovasc. Intervent. Radiol."}],"container-title":["European Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X26004699?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X26004699?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T06:48:12Z","timestamp":1790232492000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0720048X26004699"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,11]]},"references-count":30,"alternative-id":["S0720048X26004699"],"URL":"https:\/\/doi.org\/10.1016\/j.ejrad.2026.113121","relation":{},"ISSN":["0720-048X"],"issn-type":[{"value":"0720-048X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Improved detection of endovascular stent fractures with photon counting computed tomography: A phantom study","name":"articletitle","label":"Article Title"},{"value":"European Journal of Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejrad.2026.113121","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"113121"}}