{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T07:37:31Z","timestamp":1792741051628,"version":"4.5.0"},"reference-count":17,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T00:00:00Z","timestamp":1788134400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007195","name":"Universit\u00e0 degli Studi di Napoli Federico II","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007195","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100013168","name":"Istituto Nazionale di Fisica Nucleare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100013168","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","ejradiology.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Radiology"],"published-print":{"date-parts":[[2026,12]]},"DOI":"10.1016\/j.ejrad.2026.113198","type":"journal-article","created":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T05:57:08Z","timestamp":1788155828000},"page":"113198","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Patient dose in HR-pQCT bone scans can be reduced by suitably setting the tube start angle: A proof of concept"],"prefix":"10.1016","volume":"205","author":[{"given":"Laura Antonia","family":"Cerbone","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Youfang","family":"Lai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xun","family":"Jia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven K.","family":"Boyd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Mettivier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9409-0008","authenticated-orcid":false,"given":"Paolo","family":"Russo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"9","key":"10.1016\/j.ejrad.2026.113198_b0005","doi-asserted-by":"crossref","first-page":"1607","DOI":"10.1007\/s00198-020-05438-5","article-title":"Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography","volume":"31","author":"Whittier","year":"2020","journal-title":"Osteoporos Int."},{"key":"10.1016\/j.ejrad.2026.113198_b0010","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.bone.2015.06.006","article-title":"Human trabecular bone microarchitecture can be assessed independently of density with second generation HR-pQCT","volume":"79","author":"Manske","year":"2015","journal-title":"Bone"},{"issue":"2","key":"10.1016\/j.ejrad.2026.113198_b0015","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1007\/s11914-013-0142-7","article-title":"Clinical imaging of bone microarchitecture with HR-pQCT","volume":"11","author":"Nishiyama","year":"2013","journal-title":"Curr. Osteoporos. Rep."},{"issue":"9","key":"10.1016\/j.ejrad.2026.113198_b0020","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/adc9f6","article-title":"Absorbed and effective dose estimates in HR-pQCT of the distal radius and tibia: virtual dosimetry with a GPU-accelerated Monte Carlo code","volume":"70","author":"Cerbone","year":"2025","journal-title":"Phys. Med. Biol."},{"key":"10.1016\/j.ejrad.2026.113198_b0025","doi-asserted-by":"crossref","first-page":"2707","DOI":"10.1007\/s00330-010-1845-0","article-title":"Radiation exposure in X-ray based imaging techniques in osteoporosis","volume":"20","author":"Damilakis","year":"2010","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ejrad.2026.113198_b0030","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6498\/ae02a2","article-title":"Essentials of the system of radiological protection","volume":"45","author":"R\u00fchm","year":"2025","journal-title":"J. Radiol. Prot."},{"issue":"2","key":"10.1016\/j.ejrad.2026.113198_b0035","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1002\/mp.14000","article-title":"CT is still not a low-dose imaging modality","volume":"47","author":"Rehani","year":"2020","journal-title":"Med. Phys."},{"issue":"10","key":"10.1016\/j.ejrad.2026.113198_b0040","doi-asserted-by":"crossref","first-page":"7080","DOI":"10.1002\/mp.17290","article-title":"Patient radiation risk reduction by controlling the tube start angle in single and dual source spiral CT scans: a simulation study","volume":"51","author":"Baader","year":"2024","journal-title":"Med. Phys."},{"issue":"7","key":"10.1016\/j.ejrad.2026.113198_b0045","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1038\/nmeth.2019","article-title":"Fiji: an open-source platform for biological-image analysis","volume":"9","author":"Schindelin","year":"2012","journal-title":"Nat. Methods"},{"issue":"12","key":"10.1016\/j.ejrad.2026.113198_b0050","doi-asserted-by":"crossref","first-page":"7368","DOI":"10.1118\/1.4766436","article-title":"A GPU tool for efficient, accurate, and realistic simulation of cone beam CT projections","volume":"39","author":"Jia","year":"2012","journal-title":"Med. Phys."},{"issue":"3","key":"10.1016\/j.ejrad.2026.113198_b0055","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1088\/0031-9155\/57\/3\/577","article-title":"Fast Monte Carlo simulation for patient-specific CT\/CBCT imaging dose calculation","volume":"57","author":"Jia","year":"2012","journal-title":"Phys. Med. Biol."},{"issue":"7","key":"10.1016\/j.ejrad.2026.113198_b0060","doi-asserted-by":"crossref","first-page":"3630","DOI":"10.1002\/mp.14945","article-title":"SpekPy v2.0-a software toolkit for modelling x-ray tube spectra","volume":"48","author":"Poludniowski","year":"2021","journal-title":"Med. Phys."},{"key":"10.1016\/j.ejrad.2026.113198_b0065","unstructured":"ICRP, 2007. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann. ICRP 2007;37:2-4. https:\/\/www.icrp.org\/publication.asp?id=ICRP%20Publication%20103."},{"issue":"5","key":"10.1016\/j.ejrad.2026.113198_b0070","doi-asserted-by":"crossref","DOI":"10.1088\/2057-1976\/2\/5\/055010","article-title":"TIGRE: a MATLAB-GPU toolbox for CBCT image reconstruction","volume":"2","author":"Biguri","year":"2016","journal-title":"Biomed. Phys. Eng. Express"},{"key":"10.1016\/j.ejrad.2026.113198_b0075","doi-asserted-by":"crossref","first-page":"5654","DOI":"10.1118\/1.3259773","article-title":"Reducing radiation dose to selected organs by selecting the tube start angle in MDCT helical scans: a Monte Carlo based study","volume":"36","author":"Zhang","year":"2009","journal-title":"Med. Phys."},{"key":"10.1016\/j.ejrad.2026.113198_b0080","doi-asserted-by":"crossref","unstructured":"Winslow, J.F., Tien C.J., Hintenlang D.E. Organ dose and inherent uncertainty in helical CT dosimetry due to quasiperiodic dose distributions. Med Phys. 2011;38(6):3177-3185.8. Doi: 10.1118\/1.3590367.","DOI":"10.1118\/1.3590367"},{"key":"10.1016\/j.ejrad.2026.113198_b0085","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/j.ejmp.2016.04.012","article-title":"Modeling of couch transmission in the RayStation treatment planning system","volume":"32","author":"Savini","year":"2016","journal-title":"Phys. Med."}],"container-title":["European Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X26005462?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0720048X26005462?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T06:38:47Z","timestamp":1792737527000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0720048X26005462"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,12]]},"references-count":17,"alternative-id":["S0720048X26005462"],"URL":"https:\/\/doi.org\/10.1016\/j.ejrad.2026.113198","relation":{},"ISSN":["0720-048X"],"issn-type":[{"value":"0720-048X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Patient dose in HR-pQCT bone scans can be reduced by suitably setting the tube start angle: A proof of concept","name":"articletitle","label":"Article Title"},{"value":"European Journal of Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejrad.2026.113198","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"113198"}}