{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T07:11:09Z","timestamp":1791616269936,"version":"4.3.4"},"reference-count":83,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,1,8]],"date-time":"2021-01-08T00:00:00Z","timestamp":1610064000000},"content-version":"vor","delay-in-days":7,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004830","name":"Siemens","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004830","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004313","name":"General Electric","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004313","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004320","name":"Philips","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004320","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","ejropen.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Radiology Open"],"published-print":{"date-parts":[[2021]]},"DOI":"10.1016\/j.ejro.2021.100324","type":"journal-article","created":{"date-parts":[[2021,1,20]],"date-time":"2021-01-20T12:08:58Z","timestamp":1611144538000},"page":"100324","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":41,"special_numbering":"C","title":["Dual energy imaging in cardiothoracic pathologies: A primer for radiologists and clinicians"],"prefix":"10.1016","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5345-6763","authenticated-orcid":false,"given":"Amit","family":"Gupta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8932-3433","authenticated-orcid":false,"given":"Elias G","family":"Kikano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaustav","family":"Bera","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1763-8919","authenticated-orcid":false,"given":"Dhiraj","family":"Baruah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3270-5876","authenticated-orcid":false,"given":"Sachin S","family":"Saboo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3254-4809","authenticated-orcid":false,"given":"Simon","family":"Lennartz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7928-0487","authenticated-orcid":false,"given":"Nils Gro\u00dfe","family":"Hokamp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6930-4246","authenticated-orcid":false,"given":"Ali","family":"Gholamrezanezhad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert C","family":"Gilkeson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5600-5914","authenticated-orcid":false,"given":"Kai R","family":"Laukamp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"8","key":"10.1016\/j.ejro.2021.100324_bib0005","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1088\/0031-9155\/29\/8\/004","article-title":"Discrimination between thorotrast and iodine contrast medium by means of dual-energy CT scanning","volume":"29","author":"Takai","year":"1984","journal-title":"Phys. Med. Biol."},{"issue":"5","key":"10.1016\/j.ejro.2021.100324_bib0010","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1118\/1.594520","article-title":"Noise considerations in dual energy CT scanning","volume":"6","author":"Kelcz","year":"1979","journal-title":"Med. Phys."},{"issue":"8","key":"10.1016\/j.ejro.2021.100324_bib0015","doi-asserted-by":"crossref","first-page":"4877","DOI":"10.1118\/1.4959554","article-title":"Image quality comparison between single energy and dual energy CT protocols for hepatic imaging","volume":"43","author":"Yao","year":"2016","journal-title":"Med. Phys."},{"issue":"5 Suppl","key":"10.1016\/j.ejro.2021.100324_bib0020","doi-asserted-by":"crossref","first-page":"S64","DOI":"10.2214\/AJR.12.9196","article-title":"Dual-energy CT applications in the abdomen","volume":"199","author":"Heye","year":"2012","journal-title":"AJR Am. J. Roentgenol."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0025","doi-asserted-by":"crossref","first-page":"555","DOI":"10.3348\/kjr.2017.18.4.555","article-title":"Dual-energy C.T.: new horizon in medical imaging","volume":"18","author":"Goo","year":"2017","journal-title":"Korean J. Radiol."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0030","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1148\/rg.304095175","article-title":"Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging?","volume":"30","author":"Coursey","year":"2010","journal-title":"Radiographics"},{"key":"10.1016\/j.ejro.2021.100324_bib0035","series-title":"Organ Doses in Diagnostic Radiology","author":"Rosenstein","year":"1976"},{"key":"10.1016\/j.ejro.2021.100324_bib0040","series-title":"The Physics of Radiology","author":"Johns","year":"1983"},{"issue":"2","key":"10.1016\/j.ejro.2021.100324_bib0045","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1097\/RTI.0b013e31819ca7b2","article-title":"Basic principles and postprocessing techniques of dual-energy CT: illustrated by selected congenital abnormalities of the thorax","volume":"24","author":"Godoy","year":"2009","journal-title":"J. Thorac. Imaging"},{"issue":"8","key":"10.1016\/j.ejro.2021.100324_bib0050","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1097\/00004424-199008000-00003","article-title":"Evaluation of postprocessing dual-energy methods in quantitative computed tomography. Part 2. Practical aspects","volume":"25","author":"van Kuijk","year":"1990","journal-title":"Invest. Radiol."},{"issue":"8","key":"10.1016\/j.ejro.2021.100324_bib0055","doi-asserted-by":"crossref","first-page":"1739","DOI":"10.1118\/1.1494832","article-title":"A dual-energy subtraction technique for microcalcification imaging in digital mammography--a signal-to-noise analysis","volume":"29","author":"Lemacks","year":"2002","journal-title":"Med. Phys."},{"issue":"2","key":"10.1016\/j.ejro.2021.100324_bib0060","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.ejrad.2009.03.046","article-title":"Dual energy subtraction: principles and clinical applications","volume":"72","author":"Vock","year":"2009","journal-title":"Eur. J. Radiol."},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0065","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1148\/radiology.168.1.3289096","article-title":"One-shot dual-energy subtraction chest imaging with computed radiography: clinical evaluation of film images","volume":"168","author":"Ishigaki","year":"1988","journal-title":"Radiology"},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0070","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1148\/radiology.161.1.3532182","article-title":"One-shot dual-energy subtraction imaging","volume":"161","author":"Ishigaki","year":"1986","journal-title":"Radiology"},{"issue":"6","key":"10.1016\/j.ejro.2021.100324_bib0075","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.2214\/ajr.181.6.1811519","article-title":"Dual-energy chest radiography with a flat-panel digital detector: revealing calcified chest abnormalities","volume":"181","author":"Fischbach","year":"2003","journal-title":"AJR Am. J. Roentgenol."},{"issue":"1 Suppl 1","key":"10.1016\/j.ejro.2021.100324_bib0080","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/BF03168062","article-title":"Clinical application of single dual-energy subtraction technique with digital storage-phosphor radiography","volume":"8","author":"Kamimura","year":"1995","journal-title":"J. Digit. Imaging"},{"issue":"3","key":"10.1016\/j.ejro.2021.100324_bib0085","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/S0720-048X(02)00269-3","article-title":"Detection of simulated pulmonary nodules by single-exposure dual-energy computed radiography of the chest: effect of a computer-aided diagnosis system (Part 2)","volume":"44","author":"Kido","year":"2002","journal-title":"Eur. J. Radiol."},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0090","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1097\/RTI.0b013e3181aa34ed","article-title":"Dual energy subtraction digital radiography improves performance of a next generation computer-aided detection program","volume":"25","author":"Balkman","year":"2010","journal-title":"J. Thorac. Imaging"},{"issue":"5","key":"10.1016\/j.ejro.2021.100324_bib0095","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.2214\/AJR.12.8877","article-title":"Comparison of dual-energy subtraction and electronic bone suppression combined with computer-aided detection on chest radiographs: effect on human observers\u2019 performance in nodule detection","volume":"200","author":"Szucs-Farkas","year":"2013","journal-title":"AJR Am. J. Roentgenol."},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0100","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1148\/radiol.2461061848","article-title":"Lung cancers missed on chest radiographs: results obtained with a commercial computer-aided detection program","volume":"246","author":"Li","year":"2008","journal-title":"Radiology"},{"issue":"6","key":"10.1016\/j.ejro.2021.100324_bib0105","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1007\/s00330-009-1667-0","article-title":"Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: comparison with human observers","volume":"20","author":"Szucs-Farkas","year":"2010","journal-title":"Eur. Radiol."},{"issue":"3","key":"10.1016\/j.ejro.2021.100324_bib0110","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0174285","article-title":"Diagnostic accuracy and added value of dual-energy subtraction radiography compared to standard conventional radiography using computed tomography as standard of reference","volume":"12","author":"Martini","year":"2017","journal-title":"PLoS One"},{"issue":"2","key":"10.1016\/j.ejro.2021.100324_bib0115","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1067\/mdr.2002.122856","article-title":"Dual-energy digital subtraction chest radiography: technical considerations","volume":"31","author":"Whitman","year":"2002","journal-title":"Curr. Probl. Diagn. Radiol."},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0120","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1148\/rg.261055034","article-title":"Dual-energy subtraction chest radiography: what to look for beyond calcified nodules","volume":"26","author":"Kuhlman","year":"2006","journal-title":"Radiographics"},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0125","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.acra.2017.06.015","article-title":"Added value of bone subtraction in dual-energy digital radiography in the detection of pneumothorax: impact of reader expertise and medical specialty","volume":"25","author":"Urbaneja","year":"2018","journal-title":"Acad. Radiol."},{"issue":"2","key":"10.1016\/j.ejro.2021.100324_bib0130","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1118\/1.596372","article-title":"Comparison of dual and single exposure techniques in dual-energy chest radiography","volume":"16","author":"Ho","year":"1989","journal-title":"Med. Phys."},{"key":"10.1016\/j.ejro.2021.100324_bib0135","first-page":"544","article-title":"Dual energy subtraction computed chest radiography: comparison of diagnostic accuracy with conventional computed radiography","volume":"209","author":"MacMahon","year":"1998","journal-title":"Radiology"},{"issue":"5","key":"10.1016\/j.ejro.2021.100324_bib0140","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.2214\/ajr.183.5.1831233","article-title":"Digital radiography with dual-energy subtraction: improved evaluation of cardiac calcification","volume":"183","author":"Gilkeson","year":"2004","journal-title":"AJR Am. J. Roentgenol."},{"issue":"5","key":"10.1016\/j.ejro.2021.100324_bib0145","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1253\/circj.66.473","article-title":"Clinical significance of coronary calcification","volume":"66","author":"Yamanaka","year":"2002","journal-title":"Circ. J."},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0150","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1007\/s10278-011-9385-y","article-title":"Assessment of coronary artery calcium using dual-energy subtraction digital radiography","volume":"25","author":"Mafi","year":"2012","journal-title":"J. Digit. Imaging"},{"issue":"8","key":"10.1016\/j.ejro.2021.100324_bib0155","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1056\/NEJMra1313875","article-title":"Aortic-valve stenosis--from patients at risk to severe valve obstruction","volume":"371","author":"Otto","year":"2014","journal-title":"N. Engl. J. Med."},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0160","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1148\/radiol.2411051163","article-title":"Prevalence and clinical importance of aortic valve calcification detected incidentally on CT scans: comparison with echocardiography","volume":"241","author":"Koos","year":"2006","journal-title":"Radiology"},{"key":"10.1016\/j.ejro.2021.100324_bib0165","doi-asserted-by":"crossref","DOI":"10.1097\/RTI.0000000000000472","article-title":"Dual-energy subtraction chest radiography: application in cardiovascular imaging","author":"Ansari-Gilani","year":"2020","journal-title":"J. Thorac. Imaging"},{"issue":"2","key":"10.1016\/j.ejro.2021.100324_bib0170","doi-asserted-by":"crossref","first-page":"271","DOI":"10.2214\/ajr.162.2.8310908","article-title":"Conventional chest radiography vs dual-energy computed radiography in the detection and characterization of pulmonary nodules","volume":"162","author":"Kelcz","year":"1994","journal-title":"AJR Am. J. Roentgenol."},{"issue":"5","key":"10.1016\/j.ejro.2021.100324_bib0175","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1088\/0031-9155\/21\/5\/002","article-title":"Energy-selective reconstructions in X-ray computerized tomography","volume":"21","author":"Alvarez","year":"1976","journal-title":"Phys. Med. Biol."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0180","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/0010-4825(76)90069-X","article-title":"Energy dependent reconstruction in X-ray computerized tomography","volume":"6","author":"Macovski","year":"1976","journal-title":"Comput. Biol. Med."},{"issue":"3","key":"10.1016\/j.ejro.2021.100324_bib0185","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and multi-energy CT: principles, technical approaches, and clinical applications","volume":"276","author":"McCollough","year":"2015","journal-title":"Radiology"},{"issue":"7","key":"10.1016\/j.ejro.2021.100324_bib0190","doi-asserted-by":"crossref","first-page":"1955","DOI":"10.1148\/rg.2017170100","article-title":"Update on cardiovascular applications of multienergy CT","volume":"37","author":"Kalisz","year":"2017","journal-title":"Radiographics"},{"issue":"8","key":"10.1016\/j.ejro.2021.100324_bib0195","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0183759","article-title":"Intra-individual comparison between abdominal virtual mono-energetic spectral and conventional images using a novel spectral detector CT","volume":"12","author":"Doerner","year":"2017","journal-title":"PLoS One"},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0200","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1148\/radiol.2019190792","article-title":"Dual-energy CT to differentiate small foci of intracranial hemorrhage from calcium","volume":"294","author":"Wiggins","year":"2020","journal-title":"Radiology"},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0205","doi-asserted-by":"crossref","first-page":"W314","DOI":"10.2214\/AJR.13.11682","article-title":"Applications of dual-energy CT in emergency radiology","volume":"202","author":"Aran","year":"2014","journal-title":"AJR Am. J. Roentgenol."},{"issue":"7","key":"10.1016\/j.ejro.2021.100324_bib0210","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1097\/RLI.0000000000000458","article-title":"Dual-energy computed tomography-based display of bone marrow edema in incidental vertebral compression fractures: diagnostic accuracy and characterization in oncological patients undergoing routine staging computed tomography","volume":"53","author":"Frellesen","year":"2018","journal-title":"Invest. Radiol."},{"issue":"5","key":"10.1016\/j.ejro.2021.100324_bib0215","doi-asserted-by":"crossref","first-page":"2226","DOI":"10.1007\/s00330-018-5844-x","article-title":"Dual-energy CT in early acute pancreatitis: improved detection using iodine quantification","volume":"29","author":"Martin","year":"2019","journal-title":"Eur. Radiol."},{"issue":"3","key":"10.1016\/j.ejro.2021.100324_bib0220","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1097\/RTI.0000000000000259","article-title":"Monoenergetic dual-energy computed tomographic imaging: cardiothoracic applications","volume":"32","author":"Lenga","year":"2017","journal-title":"J. Thorac. Imaging"},{"key":"10.1016\/j.ejro.2021.100324_bib0225","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2019.108666","article-title":"Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography","volume":"122","author":"Arendt","year":"2020","journal-title":"Eur. J. Radiol."},{"issue":"8","key":"10.1016\/j.ejro.2021.100324_bib0230","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1097\/RLI.0b013e3182879482","article-title":"Effectiveness of automated quantification of pulmonary perfused blood volume using dual-energy CTPA for the severity assessment of acute pulmonary embolism","volume":"48","author":"Meinel","year":"2013","journal-title":"Invest. Radiol."},{"issue":"2","key":"10.1016\/j.ejro.2021.100324_bib0235","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1148\/radiol.2018180594","article-title":"Dual-energy CT angiography for detection of pulmonary emboli: incremental benefit of iodine maps","volume":"289","author":"Weidman","year":"2018","journal-title":"Radiology"},{"issue":"5","key":"10.1016\/j.ejro.2021.100324_bib0240","doi-asserted-by":"crossref","first-page":"2712","DOI":"10.1007\/s00330-019-06650-6","article-title":"Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: a comparative study","volume":"30","author":"Abdellatif","year":"2020","journal-title":"Eur. Radiol."},{"issue":"9","key":"10.1016\/j.ejro.2021.100324_bib0245","doi-asserted-by":"crossref","first-page":"4603","DOI":"10.1007\/s00330-018-5982-1","article-title":"Single- and dual-energy CT pulmonary angiography using second- and third-generation dual-source CT systems: comparison of radiation dose and image quality","volume":"29","author":"Lenga","year":"2019","journal-title":"Eur. Radiol."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0250","doi-asserted-by":"crossref","first-page":"775","DOI":"10.2214\/AJR.19.21818","article-title":"Utility of iodine density perfusion maps from dual-energy spectral detector CT in evaluating cardiothoracic conditions: a primer for the radiologist","volume":"214","author":"Kikano","year":"2020","journal-title":"AJR Am. J. Roentgenol."},{"key":"10.1016\/j.ejro.2021.100324_bib0255","article-title":"Carotid and cerebrovascular dual-energy computed tomography angiography: optimization of window settings for virtual monoenergetic imaging reconstruction","volume":"130","author":"D\u2019Angelo","year":"2020","journal-title":"Eur. J. Radiol."},{"issue":"1098","key":"10.1016\/j.ejro.2021.100324_bib0260","article-title":"Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications","volume":"92","author":"D\u2019Angelo","year":"2019","journal-title":"Br. J. Radiol."},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0265","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/j.ejrad.2014.09.009","article-title":"Added value of lung perfused blood volume images using dual-energy CT for assessment of acute pulmonary embolism","volume":"84","author":"Okada","year":"2015","journal-title":"Eur. J. Radiol."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0270","doi-asserted-by":"crossref","first-page":"1719","DOI":"10.1007\/s00330-017-5114-3","article-title":"Dual-layer DECT for multiphasic hepatic CT with 50 percent iodine load: a matched-pair comparison with a 120 kVp protocol","volume":"28","author":"Nagayama","year":"2018","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ejro.2021.100324_bib0275","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.ejrad.2018.05.028","article-title":"Dual-energy CT of the heart current and future status","volume":"105","author":"Albrecht","year":"2018","journal-title":"Eur. J. Radiol."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0280","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.jcct.2014.06.003","article-title":"Reduced iodine load with CT coronary angiography using dual-energy imaging: a prospective randomized trial compared with standard coronary CT angiography","volume":"8","author":"Raju","year":"2014","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"10.1016\/j.ejro.2021.100324_bib0285","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.ejrad.2017.05.013","article-title":"Metal artifact reduction by dual-layer computed tomography using virtual monoenergetic images","volume":"93","author":"Neuhaus","year":"2017","journal-title":"Eur. J. Radiol."},{"issue":"3","key":"10.1016\/j.ejro.2021.100324_bib0290","doi-asserted-by":"crossref","first-page":"580","DOI":"10.2214\/AJR.15.14896","article-title":"Dual-energy CT-based differentiation of benign posttreatment changes from primary or recurrent malignancy of the head and neck: comparison of spectral hounsfield units at 40 and 70 keV and iodine concentration","volume":"206","author":"Yamauchi","year":"2016","journal-title":"AJR Am. J. Roentgenol."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0295","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1016\/j.rcl.2018.03.011","article-title":"Role of dual-energy computed tomography in thoracic oncology","volume":"56","author":"Odisio","year":"2018","journal-title":"Radiol. Clin. North Am."},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0300","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1148\/rg.2016150081","article-title":"Dual-energy CT: spectrum of thoracic abnormalities","volume":"36","author":"Otrakji","year":"2016","journal-title":"Radiographics"},{"issue":"6","key":"10.1016\/j.ejro.2021.100324_bib0305","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1080\/02656736.2016.1274435","article-title":"Role of dual-energy computed tomography in detecting early recurrences of lung tumours treated with radiofrequency ablation","volume":"33","author":"Izaaryene","year":"2017","journal-title":"Int. J. Hyperthermia"},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0310","doi-asserted-by":"crossref","first-page":"W58","DOI":"10.2214\/AJR.16.16087","article-title":"Dual-energy CT of incidental findings in the abdomen: can we reduce the need for follow-up imaging?","volume":"207","author":"Wortman","year":"2016","journal-title":"AJR Am. J. Roentgenol."},{"issue":"2","key":"10.1016\/j.ejro.2021.100324_bib0315","doi-asserted-by":"crossref","first-page":"329","DOI":"10.2214\/AJR.13.11811","article-title":"Adrenal Incidentaloma triage with single-source (fast-kilovoltage switch) dual-energy CT","volume":"203","author":"Glazer","year":"2014","journal-title":"AJR Am. J. Roentgenol."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0320","doi-asserted-by":"crossref","first-page":"436","DOI":"10.4103\/ijri.IJRI_35_18","article-title":"Evaluation of lung transplant perfusion using iodine maps from novel spectral detector computed tomography","volume":"28","author":"Hokamp","year":"2018","journal-title":"Indian J. Radiol. Imaging"},{"issue":"17","key":"10.1016\/j.ejro.2021.100324_bib0325","doi-asserted-by":"crossref","first-page":"1419","DOI":"10.1136\/hrt.2008.158618","article-title":"Detection of myocardial infarction by dual-source coronary computed tomography angiography using quantitated myocardial scintigraphy as the reference standard","volume":"95","author":"Rubinshtein","year":"2009","journal-title":"Heart"},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0330","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.ejrad.2014.12.013","article-title":"Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease","volume":"84","author":"Carrascosa","year":"2015","journal-title":"Eur. J. Radiol."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0335","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1093\/jrr\/rrv100","article-title":"Prognostic impact of average iodine density assessed by dual-energy spectral imaging for predicting lung tumor recurrence after stereotactic body radiotherapy","volume":"57","author":"Aoki","year":"2016","journal-title":"J. Radiat. Res."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0340","doi-asserted-by":"crossref","first-page":"741","DOI":"10.2214\/AJR.18.20065","article-title":"Comparison of radiation dose and image quality of contrast-enhanced dual-source CT of the chest: single-versus dual-energy and second-versus third-generation technology","volume":"212","author":"Lenga","year":"2019","journal-title":"AJR Am. J. Roentgenol."},{"issue":"10","key":"10.1016\/j.ejro.2021.100324_bib0345","doi-asserted-by":"crossref","first-page":"2139","DOI":"10.1007\/s00330-011-2162-y","article-title":"Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT","volume":"21","author":"Bauer","year":"2011","journal-title":"Eur. Radiol."},{"issue":"10","key":"10.1016\/j.ejro.2021.100324_bib0350","doi-asserted-by":"crossref","first-page":"5260","DOI":"10.1002\/mp.12475","article-title":"Assessing lung function using contrast-enhanced dual-energy computed tomography for potential applications in radiation therapy","volume":"44","author":"Lapointe","year":"2017","journal-title":"Med. Phys."},{"issue":"4","key":"10.1016\/j.ejro.2021.100324_bib0355","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1111\/echo.14649","article-title":"Multimodality approach to the diagnosis and management of constrictive pericarditis","volume":"37","author":"Ansari-Gilani","year":"2020","journal-title":"Echocardiography"},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0360","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s41205-019-0038-y","article-title":"Utility of virtual monoenergetic images from spectral detector computed tomography in improving image segmentation for purposes of 3D printing and modeling","volume":"5","author":"Kikano","year":"2019","journal-title":"3D Print Med"},{"issue":"3","key":"10.1016\/j.ejro.2021.100324_bib0365","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1590\/S1806-37132015000004479","article-title":"PET\/CT imaging in lung cancer: indications and findings","volume":"41","author":"Hochhegger","year":"2015","journal-title":"J. Bras. Pneumol."},{"issue":"8","key":"10.1016\/j.ejro.2021.100324_bib0370","first-page":"1369","article-title":"A combined PET\/CT scanner for clinical oncology","volume":"41","author":"Beyer","year":"2000","journal-title":"J. Nucl. Med."},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0375","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1186\/s41747-018-0047-4","article-title":"Rationale and design of a prospective study on the first integrated PET\/dual-energy CT system for staging and image-based radiation therapy planning of lung cancer","volume":"2","author":"De Cecco","year":"2018","journal-title":"Eur. Radiol. Exp."},{"key":"10.1016\/j.ejro.2021.100324_bib0380","series-title":"2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS\/MIC)","first-page":"1","article-title":"PET-enabled dual-energy CT: a proof-of-concept simulation study","author":"Wang","year":"2018"},{"issue":"2","key":"10.1016\/j.ejro.2021.100324_bib0385","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1148\/radiol.2018172656","article-title":"Photon-counting CT: technical principles and clinical prospects","volume":"289","author":"Willemink","year":"2018","journal-title":"Radiology"},{"issue":"3","key":"10.1016\/j.ejro.2021.100324_bib0390","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1148\/rg.2019180115","article-title":"Photon-counting detector CT: system design and clinical applications of an emerging technology","volume":"39","author":"Leng","year":"2019","journal-title":"Radiographics"},{"issue":"1","key":"10.1016\/j.ejro.2021.100324_bib0395","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1148\/radiol.2016152601","article-title":"Abdominal imaging with contrast-enhanced photon-counting CT: first human experience","volume":"279","author":"Pourmorteza","year":"2016","journal-title":"Radiology"},{"issue":"2","key":"10.1016\/j.ejro.2021.100324_bib0400","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1148\/radiol.2015151169","article-title":"Radiomics: images are more than pictures, they are data","volume":"278","author":"Gillies","year":"2016","journal-title":"Radiology"},{"issue":"38","key":"10.1016\/j.ejro.2021.100324_bib0405","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1200\/EDBK_199747","article-title":"Novel quantitative imaging for predicting response to therapy: techniques and clinical applications","volume":"38","author":"Bera","year":"2018","journal-title":"Am. Soc. Clin. Oncol. Educ. Book"},{"issue":"11","key":"10.1016\/j.ejro.2021.100324_bib0410","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1038\/s41571-019-0252-y","article-title":"Artificial intelligence in digital pathology - new tools for diagnosis and precision oncology","volume":"16","author":"Bera","year":"2019","journal-title":"Nat. Rev. Clin. Oncol."},{"key":"10.1016\/j.ejro.2021.100324_bib0415","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1016\/j.csbj.2019.07.004","article-title":"Dual-energy CT texture analysis with machine learning for the evaluation and characterization of cervical lymphadenopathy","volume":"17","author":"Seidler","year":"2019","journal-title":"Comput. Struct. Biotechnol. J."}],"container-title":["European Journal of Radiology Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352047721000046?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352047721000046?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T12:48:48Z","timestamp":1762433328000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352047721000046"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021]]},"references-count":83,"alternative-id":["S2352047721000046"],"URL":"https:\/\/doi.org\/10.1016\/j.ejro.2021.100324","relation":{},"ISSN":["2352-0477"],"issn-type":[{"value":"2352-0477","type":"print"}],"subject":[],"published":{"date-parts":[[2021]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Dual energy imaging in cardiothoracic pathologies: A primer for radiologists and clinicians","name":"articletitle","label":"Article Title"},{"value":"European Journal of Radiology Open","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejro.2021.100324","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"100324"}}