{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T03:57:51Z","timestamp":1790827071733,"version":"4.1.0"},"reference-count":27,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2013,3,1]],"date-time":"2013-03-01T00:00:00Z","timestamp":1362096000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,3,1]],"date-time":"2013-03-01T00:00:00Z","timestamp":1362096000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2014,6,5]],"date-time":"2014-06-05T00:00:00Z","timestamp":1401926400000},"content-version":"vor","delay-in-days":461,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100001659","name":"German Research Foundation","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","ejves.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Vascular and Endovascular Surgery"],"published-print":{"date-parts":[[2013,3]]},"DOI":"10.1016\/j.ejvs.2012.12.003","type":"journal-article","created":{"date-parts":[[2013,1,11]],"date-time":"2013-01-11T18:41:13Z","timestamp":1357929673000},"page":"241-247","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":48,"title":["Accuracy and Variability of Semiautomatic Centerline Analysis versus Manual Aortic Measurement Techniques for TEVAR"],"prefix":"10.1016","volume":"45","author":[{"given":"M.","family":"M\u00fcller-Eschner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Rengier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Partovi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.F.","family":"Weber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Kopp-Schneider","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Geisb\u00fcsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.-U.","family":"Kauczor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.","family":"von Tengg-Kobligk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"11","key":"10.1016\/j.ejvs.2012.12.003_bib1","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1007\/s00117-007-1583-8","article-title":"Image postprocessing of aortic CTA and MRA","volume":"47","author":"von Tengg-Kobligk","year":"2007","journal-title":"Radiologe"},{"issue":"1","key":"10.1016\/j.ejvs.2012.12.003_bib2","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.jvs.2003.09.022","article-title":"Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the Zenith multicenter trial","volume":"39","author":"Sternbergh","year":"2004","journal-title":"J\u00a0Vasc Surg"},{"issue":"10","key":"10.1016\/j.ejvs.2012.12.003_bib3","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1016\/j.jacc.2009.11.047","article-title":"Endovascular aortic repair versus open surgical repair for descending thoracic aortic disease a systematic review and meta-analysis of comparative studies","volume":"55","author":"Cheng","year":"2010","journal-title":"J\u00a0Am Coll Cardiol"},{"issue":"7","key":"10.1016\/j.ejvs.2012.12.003_bib4","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1016\/j.jvir.2011.01.434","article-title":"Development of in vivo quantitative geometric mapping of the aortic arch for advanced endovascular aortic repair: feasibility and preliminary results","volume":"22","author":"Rengier","year":"2011","journal-title":"JVIR"},{"issue":"5","key":"10.1016\/j.ejvs.2012.12.003_bib5","doi-asserted-by":"crossref","first-page":"255","DOI":"10.2214\/AJR.08.1488","article-title":"Centerline analysis of aortic CT angiographic examinations: benefits and limitations","volume":"192","author":"Rengier","year":"2009","journal-title":"Am J Roentgenol"},{"issue":"2","key":"10.1016\/j.ejvs.2012.12.003_bib6","first-page":"247","article-title":"Normal thoracic aortic diameters by computed tomography","volume":"8","author":"Aronberg","year":"1984","journal-title":"J\u00a0Comput Assist Tomogr"},{"issue":"2","key":"10.1016\/j.ejvs.2012.12.003_bib7","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.jcmg.2007.11.005","article-title":"Aortic size assessment by noncontrast cardiac computed tomography: normal limits by age, gender, and body surface area","volume":"1","author":"Wolak","year":"2008","journal-title":"JACC Cardiovasc Imaging"},{"issue":"5","key":"10.1016\/j.ejvs.2012.12.003_bib8","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1016\/j.jcct.2008.08.002","article-title":"Assessment of the thoracic aorta by multidetector computed tomography: age- and sex-specific reference values in adults without evident cardiovascular disease","volume":"2","author":"Lin","year":"2008","journal-title":"J\u00a0Cardiovasc Comput Tomogr"},{"issue":"3","key":"10.1016\/j.ejvs.2012.12.003_bib9","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1016\/j.athoracsur.2011.03.130","article-title":"Impact of image analysis methodology on diagnostic and surgical classification of patients with thoracic aortic aneurysms","volume":"92","author":"Mendoza","year":"2011","journal-title":"Ann Thorac Surg"},{"issue":"6","key":"10.1016\/j.ejvs.2012.12.003_bib10","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1007\/s00270-010-9992-x","article-title":"Maximum diameter measurements of aortic aneurysms on axial CT images after endovascular aneurysm repair: sufficient for follow-up?","volume":"34","author":"Baum\u00fcller","year":"2011","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"2","key":"10.1016\/j.ejvs.2012.12.003_bib11","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1583\/03-976.1","article-title":"Aortic diameter is an insensitive measurement of early aneurysm expansion after endografting","volume":"11","author":"Kritpracha","year":"2004","journal-title":"J\u00a0Endovasc Ther"},{"issue":"5","key":"10.1016\/j.ejvs.2012.12.003_bib12","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1053\/ejvs.2002.1856","article-title":"Intra- and interobserver variability in the measurements of abdominal aortic and common iliac artery diameter with computed tomography. The Troms\u00f8 study","volume":"25","author":"Singh","year":"2003","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"suppl. 1","key":"10.1016\/j.ejvs.2012.12.003_bib13","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1148\/rg.26si065508","article-title":"New techniques in CT angiography","volume":"26","author":"Lell","year":"2006","journal-title":"Radiographics"},{"issue":"2","key":"10.1016\/j.ejvs.2012.12.003_bib14","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1053\/j.semvascsurg.2004.03.005","article-title":"Computed tomography assessment of thoracic aortic pathology","volume":"17","author":"Greenberg","year":"2004","journal-title":"Semin Vasc Surg"},{"issue":"3","key":"10.1016\/j.ejvs.2012.12.003_bib15","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.ejvs.2011.04.019","article-title":"Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among non-experts","volume":"42","author":"Rengier","year":"2011","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.ejvs.2012.12.003_bib16","series-title":"Applied mixed models in medicine","author":"Brown","year":"2006"},{"key":"10.1016\/j.ejvs.2012.12.003_bib17","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1198\/016214502753479392","article-title":"Statistical methods in assessing agreement: models, issues, and tools","volume":"97","author":"Lin","year":"2002","journal-title":"JASA"},{"issue":"4","key":"10.1016\/j.ejvs.2012.12.003_bib18","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1024\/0301-1526.34.4.255","article-title":"Automated software supported versus manual aorto-iliac diameter measurements in CT angiography of patients with abdominal aortic aneurysms: assessment of inter- and intraobserver variation","volume":"34","author":"Diehm","year":"2005","journal-title":"Vasa"},{"issue":"2","key":"10.1016\/j.ejvs.2012.12.003_bib19","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1510\/icvts.2009.216275","article-title":"Variability of ascending aorta diameter measurements as assessed with electrocardiography-gated multidetector computerized tomography and computer assisted diagnosis software","volume":"10","author":"Lu","year":"2010","journal-title":"Interact Cardiovasc Thorac Surg"},{"issue":"3","key":"10.1016\/j.ejvs.2012.12.003_bib20","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1067\/mva.2003.143","article-title":"Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool","volume":"37","author":"Lutz","year":"2003","journal-title":"J Vasc Surg"},{"issue":"3","key":"10.1016\/j.ejvs.2012.12.003_bib21","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1258\/ar.2010.100229","article-title":"Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms","volume":"52","author":"Pitoulias","year":"2011","journal-title":"Acta Radiol"},{"issue":"3","key":"10.1016\/j.ejvs.2012.12.003_bib22","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/s10278-004-1014-6","article-title":"OsiriX: an open-source software for navigating in multidimensional DICOM images","volume":"17","author":"Rosset","year":"2004","journal-title":"J\u00a0Digit Imaging"},{"issue":"3","key":"10.1016\/j.ejvs.2012.12.003_bib23","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1583\/11-3731MR.1","article-title":"St George's Vascular Institute Protocol: an accurate and reproducible methodology to enable comprehensive characterization of infrarenal abdominal aortic aneurysm morphology in clinical and research applications","volume":"19","author":"Ghatwary","year":"2012","journal-title":"J\u00a0Endovasc Ther"},{"issue":"10","key":"10.1016\/j.ejvs.2012.12.003_bib24","doi-asserted-by":"crossref","first-page":"2359","DOI":"10.1109\/TBME.2010.2053539","article-title":"3-D quantification of the aortic arch morphology in 3-D CTA data for endovascular aortic repair","volume":"57","author":"W\u00f6rz","year":"2010","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"10.1016\/j.ejvs.2012.12.003_bib25","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.ejrad.2010.08.023","article-title":"Heartbeat-related distension and displacement of the thoracic aorta in healthy volunteers","volume":"81","author":"Rengier","year":"2012","journal-title":"Eur J Radiol"},{"issue":"1","key":"10.1016\/j.ejvs.2012.12.003_bib26","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1007\/s00330-008-1103-x","article-title":"Assessment of thoracic aortic conformational changes by four-dimensional computed tomography angiography in patients with chronic aortic dissection type b","volume":"19","author":"Weber","year":"2009","journal-title":"Eur Radiol"},{"issue":"5","key":"10.1016\/j.ejvs.2012.12.003_bib27","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/j.ejvs.2006.05.009","article-title":"Dynamic cine-CT angiography for the evaluation of the thoracic aorta; insight in dynamic changes with implications for thoracic endograft treatment","volume":"32","author":"Muhs","year":"2006","journal-title":"Eur J Vasc Endovasc Surg"}],"container-title":["European Journal of Vascular and Endovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078588412007964?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078588412007964?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T11:38:33Z","timestamp":1761046713000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1078588412007964"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,3]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2013,3]]}},"alternative-id":["S1078588412007964"],"URL":"https:\/\/doi.org\/10.1016\/j.ejvs.2012.12.003","relation":{},"ISSN":["1078-5884"],"issn-type":[{"value":"1078-5884","type":"print"}],"subject":[],"published":{"date-parts":[[2013,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accuracy and Variability of Semiautomatic Centerline Analysis versus Manual Aortic Measurement Techniques for TEVAR","name":"articletitle","label":"Article Title"},{"value":"European Journal of Vascular and Endovascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejvs.2012.12.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}