{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T06:17:10Z","timestamp":1790835430547,"version":"4.1.0"},"reference-count":19,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2016,2,1]],"date-time":"2016-02-01T00:00:00Z","timestamp":1454284800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,2,1]],"date-time":"2016-02-01T00:00:00Z","timestamp":1454284800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2017,2,1]],"date-time":"2017-02-01T00:00:00Z","timestamp":1485907200000},"content-version":"vor","delay-in-days":366,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","ejves.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Vascular and Endovascular Surgery"],"published-print":{"date-parts":[[2016,2]]},"DOI":"10.1016\/j.ejvs.2015.07.042","type":"journal-article","created":{"date-parts":[[2015,9,24]],"date-time":"2015-09-24T11:51:40Z","timestamp":1443095500000},"page":"187-193","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":51,"title":["High Resolution Strain Analysis Comparing Aorta and Abdominal Aortic Aneurysm with Real Time Three Dimensional Speckle Tracking Ultrasound"],"prefix":"10.1016","volume":"51","author":[{"given":"W.","family":"Derwich","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Wittek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Pfister","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Nelson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Bereiter-Hahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.P.","family":"Fritzen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Blase","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"Schmitz-Rixen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejvs.2015.07.042_bib1","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1002\/bjs.8897","article-title":"Final follow up of the Multicentre Aneurysm Screening Study (MASS) randomized trial of abdominal aortic aneurysm screening","volume":"99","author":"Thompson","year":"2012","journal-title":"Br J Surg"},{"key":"10.1016\/j.ejvs.2015.07.042_bib2","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1016\/S0140-6736(98)10137-X","article-title":"Mortality results for randomised controlled trial of early elective surgery or ultrasonographic surveillance for small abdominal aortic aneurysms","volume":"352","author":"The UK Small Aneurysm Trial Participants","year":"1998","journal-title":"Lancet"},{"key":"10.1016\/j.ejvs.2015.07.042_bib3","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.ejvs.2012.11.024","article-title":"A\u00a0multicentre observational study of the outcomes of screening detected sub-aneurysmal aortic dilatation","volume":"45","author":"Wild","year":"2013","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.ejvs.2015.07.042_bib4","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1067\/mva.2003.213","article-title":"Prediction of rupture risk in abdominal aortic aneurysm during observation: wall stress versus diameter","volume":"37","author":"Fillinger","year":"2003","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.ejvs.2015.07.042_bib5","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1053\/ejvs.1999.0872","article-title":"Abdominal aortic aneurysm wall mechanics and their relation to risk of rupture","volume":"18","author":"Sonesson","year":"1999","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.ejvs.2015.07.042_bib6","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1016\/j.jvs.2005.01.004","article-title":"Size and location of thrombus in intact and ruptured abdominal aortic aneurysms","volume":"41","author":"Hans","year":"2005","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.ejvs.2015.07.042_bib7","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/S0741-5214(98)70319-2","article-title":"Predictive factors for rupture of thoraco-abdominal aortic aneurysm","volume":"27","author":"Lobato","year":"1998","journal-title":"J\u00a0Vasc Surg"},{"key":"10.1016\/j.ejvs.2015.07.042_bib8","doi-asserted-by":"crossref","first-page":"1674","DOI":"10.1046\/j.1365-2168.1998.00946.x","article-title":"Growth rates and risk of rupture of abdominal aortic aneurysms","volume":"85","author":"Vardulaki","year":"1998","journal-title":"Br J Surg"},{"key":"10.1016\/j.ejvs.2015.07.042_bib9","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/j.ejvs.2013.12.018","article-title":"A\u00a0novel strategy to translate the biomechanical rupture risk of abdominal aortic aneurysms to their equivalent diameter risk: method and retrospective validation","volume":"47","author":"Gasser","year":"2014","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.ejvs.2015.07.042_bib10","doi-asserted-by":"crossref","first-page":"1401","DOI":"10.1016\/j.jacc.2011.06.038","article-title":"Echocardiographic assessment of myocardial strain","volume":"58","author":"Gorcsan","year":"2011","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.ejvs.2015.07.042_bib11","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1161\/CIRCULATIONAHA.104.474445","article-title":"Real time three dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony","volume":"112","author":"Kapetanakis","year":"2005","journal-title":"Circulation"},{"key":"10.1016\/j.ejvs.2015.07.042_bib12","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1161\/CIRCIMAGING.109.858480","article-title":"Validation of 3 dimensional speckle tracking imaging to quantify regional myocardial deformation","volume":"2","author":"Seo","year":"2009","journal-title":"Circ Cardiovasc Imaging"},{"key":"10.1016\/j.ejvs.2015.07.042_bib13","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/j.ejvs.2013.01.004","article-title":"Strain measurement of abdominal aortic aneurysm with real time 3D ultrasound speckle tracking","volume":"45","author":"Bihari","year":"2013","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.ejvs.2015.07.042_bib14","doi-asserted-by":"crossref","first-page":"1664","DOI":"10.1016\/j.athoracsur.2013.06.037","article-title":"Method for aortic wall strain measurement with three dimensional ultrasound speckle tracking and fitted finite element analysis","volume":"96","author":"Karatolios","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.ejvs.2015.07.042_bib15","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.jmbbm.2013.03.014","article-title":"In\u00a0vivo determination of elastic properties of the human aorta based on 4D ultrasound data","volume":"27","author":"Wittek","year":"2013","journal-title":"J\u00a0Mech Behav Biomed Mater"},{"key":"10.1016\/j.ejvs.2015.07.042_bib16","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"10.1016\/j.ejvs.2015.07.042_bib17","first-page":"87","article-title":"Opposing effects of ageing on distal and proximal large arteries in hypertensives","volume":"10","author":"Boutouyrie","year":"1992","journal-title":"J\u00a0Hypertens Suppl"},{"key":"10.1016\/j.ejvs.2015.07.042_bib18","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/j.jbiomech.2013.12.012","article-title":"In\u00a0vitro analysis of localized rupture","volume":"47","author":"Romo","year":"2014","journal-title":"J\u00a0Biomech"},{"key":"10.1016\/j.ejvs.2015.07.042_bib19","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1016\/j.jvs.2005.10.072","article-title":"Biomechanical properties of ruptured versus electively repaired abdominal aortic aneurysm wall tissue","volume":"43","author":"DiMartino","year":"2006","journal-title":"J\u00a0Vasc Surg"}],"container-title":["European Journal of Vascular and Endovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078588415006048?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1078588415006048?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T11:43:28Z","timestamp":1761047008000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1078588415006048"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016,2]]}},"alternative-id":["S1078588415006048"],"URL":"https:\/\/doi.org\/10.1016\/j.ejvs.2015.07.042","relation":{},"ISSN":["1078-5884"],"issn-type":[{"value":"1078-5884","type":"print"}],"subject":[],"published":{"date-parts":[[2016,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"High Resolution Strain Analysis Comparing Aorta and Abdominal Aortic Aneurysm with Real Time Three Dimensional Speckle Tracking Ultrasound","name":"articletitle","label":"Article Title"},{"value":"European Journal of Vascular and Endovascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejvs.2015.07.042","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}