{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T18:09:10Z","timestamp":1747159750622,"version":"3.40.5"},"reference-count":10,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,1,15]],"date-time":"2024-01-15T00:00:00Z","timestamp":1705276800000},"content-version":"vor","delay-in-days":14,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["EJVES Vascular Forum"],"published-print":{"date-parts":[[2024]]},"DOI":"10.1016\/j.ejvsvf.2024.01.052","type":"journal-article","created":{"date-parts":[[2024,1,20]],"date-time":"2024-01-20T02:02:30Z","timestamp":1705716150000},"page":"51-53","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["A Tubular Vena Cava Conduit Used to Lengthen a Kidney Transplant Renal Artery Injured During Organ Procurement"],"prefix":"10.1016","volume":"61","author":[{"given":"Bogdan","family":"Bratu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Salom\u00e9","family":"Kuntz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sophie","family":"Caillard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nabil","family":"Chakfe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1041-0893","authenticated-orcid":false,"given":"Anne","family":"Lejay","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ejvsvf.2024.01.052_bib1","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1001\/jamasurg.2023.0526","article-title":"The organ shortage continues to be a crisis for patients with end-stage kidney disease","volume":"158","author":"Matas","year":"2023","journal-title":"JAMA Surg"},{"key":"10.1016\/j.ejvsvf.2024.01.052_bib2","doi-asserted-by":"crossref","first-page":"224","DOI":"10.7326\/0003-4819-145-3-200608010-00010","article-title":"How can we ethically increase the supply of transplantable organs?","volume":"145","author":"Childress","year":"2006","journal-title":"Ann Inter Med"},{"key":"10.1016\/j.ejvsvf.2024.01.052_bib3","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1016\/S0140-6736(98)09409-4","article-title":"Kidney damage during organ retrieval: data from UK national transplant database. Kidney advisory group","volume":"354","author":"Wigmore","year":"1999","journal-title":"Lancet"},{"key":"10.1016\/j.ejvsvf.2024.01.052_bib4","doi-asserted-by":"crossref","first-page":"423","DOI":"10.5500\/wjt.v6.i2.423","article-title":"Deceased donor organ procurement injuries in the United States","volume":"6","author":"Tabere","year":"2016","journal-title":"World J Transpl"},{"key":"10.1016\/j.ejvsvf.2024.01.052_bib5","doi-asserted-by":"crossref","first-page":"2791","DOI":"10.1111\/ajt.13484","article-title":"Surgical technique in transplantation: how much does it matter?","volume":"15","author":"Knechle","year":"2015","journal-title":"Am J Transpl"},{"key":"10.1016\/j.ejvsvf.2024.01.052_bib6","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.ejvs.2018.01.025","article-title":"Why should vascular surgeons be more involved in kidney transplantation?","volume":"5\u20135","author":"Lejay","year":"2018","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.ejvsvf.2024.01.052_bib7","doi-asserted-by":"crossref","first-page":"67","DOI":"10.4285\/kjt.21.0027","article-title":"The use of polytetrafluoroethylene graft for damaged renal artery in ABO-incompatible living donor kidney transplantation: a case report","volume":"36","author":"Chang","year":"2022","journal-title":"Korean J Transpl"},{"key":"10.1016\/j.ejvsvf.2024.01.052_bib8","first-page":"467","article-title":"Successful elongation of short graft renal artery by a gonadal vein","volume":"15","author":"Uysal","year":"2017","journal-title":"Exp Clin Transpl Off J Middle East Soc Organ Transpl"},{"key":"10.1016\/j.ejvsvf.2024.01.052_bib9","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1097\/00000658-200301000-00016","article-title":"Surgical repair of transplant renal artery stenosis with preserved cadaveric iliac artery grafts","volume":"237","author":"Shames","year":"2003","journal-title":"Ann Surg"},{"key":"10.1016\/j.ejvsvf.2024.01.052_bib10","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0255114","article-title":"Cryopreservation moderates the thrombogenicity of arterial allografts during storage","volume":"16","author":"Hidi","year":"2021","journal-title":"PLoS One"}],"container-title":["EJVES Vascular Forum"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666688X24000534?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666688X24000534?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,6,19]],"date-time":"2024-06-19T08:27:46Z","timestamp":1718785666000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666688X24000534"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":10,"alternative-id":["S2666688X24000534"],"URL":"https:\/\/doi.org\/10.1016\/j.ejvsvf.2024.01.052","relation":{},"ISSN":["2666-688X"],"issn-type":[{"type":"print","value":"2666-688X"}],"subject":[],"published":{"date-parts":[[2024]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A Tubular Vena Cava Conduit Used to Lengthen a Kidney Transplant Renal Artery Injured During Organ Procurement","name":"articletitle","label":"Article Title"},{"value":"EJVES Vascular Forum","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ejvsvf.2024.01.052","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Ltd on behalf of European Society for Vascular Surgery.","name":"copyright","label":"Copyright"}]}}