{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T03:59:25Z","timestamp":1782705565326,"version":"3.54.5"},"reference-count":41,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2016,10,1]],"date-time":"2016-10-01T00:00:00Z","timestamp":1475280000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Energy and Buildings"],"published-print":{"date-parts":[[2016,10]]},"DOI":"10.1016\/j.enbuild.2016.08.019","type":"journal-article","created":{"date-parts":[[2016,8,5]],"date-time":"2016-08-05T07:58:55Z","timestamp":1470383935000},"page":"308-321","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":33,"special_numbering":"C","title":["Study of tubular daylight guide systems in buildings: Experimentation, modelling and validation"],"prefix":"10.1016","volume":"129","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8216-265X","authenticated-orcid":false,"given":"Bruno","family":"Malet-Damour","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0037-2421","authenticated-orcid":false,"given":"St\u00e9phane","family":"Guichard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9967-5838","authenticated-orcid":false,"given":"Dimitri","family":"Bigot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harry","family":"Boyer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.enbuild.2016.08.019_bib0005","unstructured":"MEDDE\/SOeS, Bilan \u00e9nerg\u00e9tique de la France 2013, 2014."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0010","unstructured":"CITEPA, Rapport Secten \u2fff Plan Climat Kyoto, 2014"},{"key":"10.1016\/j.enbuild.2016.08.019_bib0015","series-title":"Besoins Et Consommations d\u2fff\u00e9nergie Dans Les b\u00e2timents, Synth\u00e8se Bibliographique Etudes De Cas","author":"Detrie","year":"2007"},{"key":"10.1016\/j.enbuild.2016.08.019_bib0020","unstructured":"ADEME, Strat\u00e9gie utilisation rationnelle de l\u2fff\u00e9nergie Chapitre II: les b\u00e2timents, 2005."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0025","unstructured":"R. Ziorjen, La cl\u00e9 du confort visuel et du bien-\u00eatre, SOLATUBE Report, 2000"},{"key":"10.1016\/j.enbuild.2016.08.019_bib0030","series-title":"Daylighting in Schools: An Investigation into the Relationship Between Daylighting and Human Performance","author":"Loisos","year":"1999"},{"key":"10.1016\/j.enbuild.2016.08.019_bib0035","first-page":"65","article-title":"Daylighting and human performance","author":"Heschong","year":"2002","journal-title":"ASHRAE J."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0040","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.enbuild.2011.10.033","article-title":"Beyond the science and art of the healthy buildings daylighting dynamic control\u2fffs performance prediction and validation","volume":"46","author":"Todorovic","year":"2012","journal-title":"Energy Build."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0045","unstructured":"V. Garcia Hansen, I. Edmonds, J.M. Bell, Improving Daylighting Performance of Mirrored Light Pipes, in: Quebec City, Canada, 2009."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0050","doi-asserted-by":"crossref","first-page":"6304","DOI":"10.3390\/en6126304","article-title":"Thermal CFD analysis of tubular light guides","volume":"6","author":"\u0160ikula","year":"2013","journal-title":"Energies"},{"key":"10.1016\/j.enbuild.2016.08.019_bib0055","unstructured":"CSTB Solatube\u00ae S160-DS, S290-DS et S330-DS \u2fff Conduit de lumi\u00e8re naturelle \u2fff Avis Technique 6\/10-1836, 2011."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0060","unstructured":"B. Malet-Damour, H. Boyer, S. Guichard, F. Miranville, Performance Testing of Light Pipes in real weather conditions for a confrontation with Hemera, in: Hong Kong \u2fff Chine, 2014."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0065","doi-asserted-by":"crossref","first-page":"1977","DOI":"10.1016\/j.egypro.2014.10.062","article-title":"Light pipes performance prediction: inter model and experimental confrontation on vertical circular light-guides","volume":"57","author":"Malet-Damour","year":"2014","journal-title":"Energy Procedia"},{"key":"10.1016\/j.enbuild.2016.08.019_bib0070","doi-asserted-by":"crossref","first-page":"2724","DOI":"10.1016\/j.enconman.2011.01.019","article-title":"Development of a new model to predict indoor daylighting: integration in CODYRUN software and validation","volume":"52","author":"Fakra","year":"2011","journal-title":"Energy Convers. Manag."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0075","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1016\/j.renene.2010.06.042","article-title":"A simple evaluation of global and diffuse luminous efficacy for all sky conditions in tropical and humid climate","volume":"36","author":"Fakra","year":"2011","journal-title":"Renew. Energy"},{"key":"10.1016\/j.enbuild.2016.08.019_bib0080","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/S0378-7788(98)00068-1","article-title":"Building ventilation: a pressure airflow model computer generation and elements of validation","volume":"29","author":"Boyer","year":"1999","journal-title":"Energy Build."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0085","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/0360-1323(96)00001-7","article-title":"Thermal building simulation and computer generation of nodal models","volume":"31","author":"Boyer","year":"1996","journal-title":"Build. Environ."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0090","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/S0378-7788(01)00115-3","article-title":"Study of moisture in buildings for hot humid climates","volume":"34","author":"Lucas","year":"2002","journal-title":"Energy Build."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0095","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/S0378-7788(99)00009-2","article-title":"A detailed weather data generator for building simulations","volume":"31","author":"Adelard","year":"2000","journal-title":"Energy Build."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0100","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.enbuild.2013.11.079","article-title":"A thermal model for phase change materials in a building roof for a tropical and humid climate: model description and elements of validation","volume":"70","author":"Guichard","year":"2014","journal-title":"Energy Build."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0105","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/S0378-7788(00)00127-4","article-title":"Empirical validation of the thermal model of a passive solar cell test","volume":"33","author":"Mara","year":"2001","journal-title":"Energy Build."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0110","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.enbuild.2012.01.013","article-title":"Evaluation of the thermal resistance of a roof-mounted multi-reflective radiant barrier for tropical and humid conditions: experimental study from field measurements","volume":"48","author":"Miranville","year":"2012","journal-title":"Energy Build."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0115","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.enbuild.2015.08.055","article-title":"Experimental investigation on a complex roof incorporating phase-change material","volume":"108","author":"Guichard","year":"2015","journal-title":"Energy Build."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0120","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1016\/j.enconman.2006.11.012","article-title":"All sky modeling daylight availability and illuminance\/irradiance on horizontal plane for Mahasarakham, Thailand","volume":"48","author":"Pattanasethanon","year":"2007","journal-title":"Energy Convers. Manag."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0125","unstructured":"B. Malet-Damour, H. Boyer, S. Guichard, A.H. Fakra, Les conduits de lumi\u00e8re de type MLP: confrontation inter-mod\u00e8le et exp\u00e9rimentale, in: Moroni Comores, 2014, 24\u2fff29."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0130","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.apenergy.2003.11.003","article-title":"Light-pipe prediction methods","volume":"79","author":"Jenkins","year":"2004","journal-title":"Appl. Energy"},{"key":"10.1016\/j.enbuild.2016.08.019_bib0135","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1016\/j.apenergy.2005.08.001","article-title":"Tubular guidance systems for daylight: achieved and predicted installation performances","volume":"83","author":"Al-Marwaee","year":"2006","journal-title":"Appl. Energy."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0140","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1177\/1420326X09358008","article-title":"Performance prediction by modelling of a light-pipe system used under the climate conditions of Korea","volume":"19","author":"Yun","year":"2010","journal-title":"Indoor Built Environ."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0145","unstructured":"J.Y. Shin, G.Y. Yun, J. Tai Kim, Daylighting and Energy Performance Prediction of a Light Pipe used in Underground Parking Lots, in: Seoul Korea, 2011, 277\u2fff281."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0150","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1177\/096032710003200306","article-title":"Mathematical model for the performance of light pipes","volume":"32","author":"Zhang","year":"2000","journal-title":"Light. Res. Amp Technol.\u2fffLight. Res Technol."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0155","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1191\/1365782802li041oa","article-title":"A design guide for performance assessment of solar light-pipes","volume":"34","author":"Zhang","year":"2002","journal-title":"Light. Res. Technol."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0160","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1177\/14771535950270010101","article-title":"Daylighting enhancement with light pipes coupled to laser-cut light-deflecting panels","volume":"27","author":"Edmonds","year":"1995","journal-title":"Light. Res. Technol."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0165","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.enbuild.2012.03.053","article-title":"Comparative monitoring and data regression of various sized commercial lightpipes","volume":"50","author":"Su","year":"2012","journal-title":"Energy Build."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0170","doi-asserted-by":"crossref","unstructured":"A. Zastrow, V. Wittwer, Daylighting with Mirror Light Pipes and with Fluorescent Planar Concentrators. First Results from the Demonstration Project Stuttgart-hohenheim, in: 1987, pp. 227\u2fff234. doi:10.1117\/12.936710.","DOI":"10.1117\/12.936710"},{"key":"10.1016\/j.enbuild.2016.08.019_bib0175","doi-asserted-by":"crossref","first-page":"2193","DOI":"10.1016\/j.buildenv.2009.03.015","article-title":"Tubular light guide evaluation","volume":"44","author":"Mohelnikova","year":"2009","journal-title":"Build. Environ."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0180","series-title":"Daylighting Performance of Tubular Solar Light Pipes: Measurement Modelling and Validation","author":"Zhang","year":"2002"},{"key":"10.1016\/j.enbuild.2016.08.019_bib0185","unstructured":"A.H. Fakra, Int\u00e9gration de mod\u00e8les d\u2fff\u00e9clairage \u00e0 un code de calcu en physique du b\u00e2timent: Mod\u00e9lisation, Validation et Applications, Th\u00e8se Sci., Universit\u00e9 de la R\u00e9union, 2009."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0190","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.enbuild.2004.09.014","article-title":"A design tool for predicting the performances of light pipes","volume":"37","author":"Jenkins","year":"2005","journal-title":"Energy Build."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0195","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1177\/1420326X11420011","article-title":"Evaluation of daylighting effectiveness and energy saving potentials of light-pipe systems in buildings","volume":"21","author":"Shin","year":"2012","journal-title":"Indoor Built Environ."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0200","article-title":"Lumi\u00e8re artificielle: d\u00e9veloppement durable et qualit\u00e9 de vie","author":"Zissis","year":"2006","journal-title":"Tech. Ing. Opt. Instrum."},{"key":"10.1016\/j.enbuild.2016.08.019_bib0205","series-title":"\u00ffclairage d\u2fffint\u00e9rieur Et Ambiances Visuelles","author":"Damelincourt","year":"2010"}],"container-title":["Energy and Buildings"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0378778816306995?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0378778816306995?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,9]],"date-time":"2018-09-09T07:59:29Z","timestamp":1536479969000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0378778816306995"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,10]]},"references-count":41,"alternative-id":["S0378778816306995"],"URL":"https:\/\/doi.org\/10.1016\/j.enbuild.2016.08.019","relation":{},"ISSN":["0378-7788"],"issn-type":[{"value":"0378-7788","type":"print"}],"subject":[],"published":{"date-parts":[[2016,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Study of tubular daylight guide systems in buildings: Experimentation, modelling and validation","name":"articletitle","label":"Article Title"},{"value":"Energy and Buildings","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.enbuild.2016.08.019","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}