{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,22]],"date-time":"2024-08-22T07:15:26Z","timestamp":1724310926435},"reference-count":12,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2023,1,4]],"date-time":"2023-01-04T00:00:00Z","timestamp":1672790400000},"content-version":"vor","delay-in-days":691,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2021,2,12]],"date-time":"2021-02-12T00:00:00Z","timestamp":1613088000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,12,30]],"date-time":"2020-12-30T00:00:00Z","timestamp":1609286400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["smoa.jsexmed.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Introduction<\/jats:title>\n                  <jats:p>Plaque incision and graft (PIG) is suggested for the treatment of significant Peyronie's disease (PD), but most surgeons perform very few PIG surgeries annually, and the number of PD cases requiring PIG is inadequate to maintain the necessary skills and completely master the procedure.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Aim<\/jats:title>\n                  <jats:p>To develop and validate a new 3D-printed model of a curved penis and graft to simulate PIG surgery. This is the first PIG surgical training simulator described in the medical literature.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>A 3D-printed model of the corpora cavernosa with a 60-degree curvature and an associated urethra was created using a flexible filament of thermoplastic polyurethane. Twenty-two urologists from Brazil were recruited to perform simulated surgery on the 3D model. The participants included 12 senior-level and 10 trainee-level urologists.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Main outcome measures<\/jats:title>\n                  <jats:p>Evaluation of the device was based on a 15-item questionnaire using a 5-point Likert-type scale for each item.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Each participant performed one simulated surgery with the 3D-printed model. All participants agreed that the simulation should be implemented into training programs. Participants ranked all content validity components \u22654.41 and all face validity components \u22653.83. The mean usability score was 4.25, and the overall experience scores were 4.75 (senior) and 5.0 (trainee).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>Senior and trainee urologists evaluated this first reported simulated PIG training model for penile curvature correction as an acceptable tool for training and maintaining necessary PIG skills. This model may\u00a0improve PIG training and surgeon skill, thereby improving patient safety and outcomes.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1016\/j.esxm.2020.100318","type":"journal-article","created":{"date-parts":[[2021,2,15]],"date-time":"2021-02-15T18:31:22Z","timestamp":1613413882000},"page":"100318-100318","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["3D-Printed Flexible Penile Model Simulator for Plaque Incision and Graft for Peyronie's Disease"],"prefix":"10.1093","volume":"9","author":[{"given":"Alexandre","family":"Miranda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2021,2,12]]},"reference":[{"key":"2023012008401830300_bib1","first-page":"905","article-title":"Evidence-based Management guidelines on Peyronie's disease","volume":"13","author":"Chung","year":"2016","journal-title":"J\u00a0Sex Med"},{"key":"2023012008401830300_bib2","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.sxmr.2018.07.001","article-title":"New developments in surgical treatment for penile size Preservation in Peyronie's disease","volume":"7","author":"Barrett-Harlow","year":"2019","journal-title":"Sex Med Rev"},{"key":"2023012008401830300_bib3","first-page":"568","article-title":"A\u00a0Worldwide survey on Peyronie's disease surgical practice patterns among surgeons","volume":"15","author":"Chung","year":"2018","journal-title":"J\u00a0Sex Med"},{"key":"2023012008401830300_bib4","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1111\/andr.292","article-title":"Peyronie's disease: urologist's knowledge base and practice patterns","volume":"3","author":"Sullivan","year":"2015","journal-title":"Andrology"},{"key":"2023012008401830300_bib5","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1038\/s41443-019-0211-2","article-title":"3D pelvic cadaver model: a novel approach to surgical training for penile implant surgery","volume":"32","author":"Renterghem","year":"2020","journal-title":"Int J Impot Res"},{"key":"2023012008401830300_bib6","first-page":"2299","article-title":"The Future of penile Prosthetic surgical training is Here: design of a Hydrogel model for inflatable penile Prosthetic Placement using modern Education theory","volume":"17","author":"Witthaus","year":"2021","journal-title":"J\u00a0Sex Med"},{"key":"2023012008401830300_bib7","first-page":"e73","article-title":"Practical Computerized Solution for incision and grafting in Peyronie's disease","volume":"4","author":"Miranda","year":"2016","journal-title":"Sex Med"},{"key":"2023012008401830300_bib8","article-title":"Practical Computerized Solution for incision and grafting in Peyronie\u2019s disease - uniplanar case, video Journal of Prosthetic urology","author":"Miranda"},{"key":"2023012008401830300_bib9","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/j.eururo.2012.05.040","article-title":"EAU guidelines on penile curvature","volume":"62","author":"Hatzimouratidis","year":"2012","journal-title":"Eur Urol"},{"key":"2023012008401830300_bib10","first-page":"745","article-title":"Peyronie's disease: AUA Guideline","volume":"194","author":"Nehra","year":"2015","journal-title":"J\u00a0Urol"},{"key":"2023012008401830300_bib11","first-page":"2350","article-title":"Subjective and objective analysis of the prevalence of Peyronie's disease in a population of men presenting for prostate cancer screening","volume":"171","author":"Mulhall","year":"2004","journal-title":"J\u00a0Urol"},{"key":"2023012008401830300_bib12","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1038\/ijir.2012.48","article-title":"How curved is too curved? The severity of penile deformity may predict sexual disability among men with Peyronie's disease","volume":"25","author":"Walsh","year":"2013","journal-title":"Int J Impot Res"}],"container-title":["Sexual Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2050116120302063?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2050116120302063?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/smoa\/article-pdf\/9\/2\/100318\/48796698\/smoa_9_2_100318.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/smoa\/article-pdf\/9\/2\/100318\/48796698\/smoa_9_2_100318.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,20]],"date-time":"2023-01-20T09:11:29Z","timestamp":1674205889000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/smoa\/article\/9\/2\/100318\/6956650"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,12]]},"references-count":12,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,4,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.esxm.2020.100318","relation":{},"ISSN":["2050-1161"],"issn-type":[{"value":"2050-1161","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,4]]},"published":{"date-parts":[[2021,2,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"3D-Printed Flexible Penile Model Simulator for Plaque Incision and Graft for Peyronie's Disease","name":"articletitle","label":"Article Title"},{"value":"Sexual Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.esxm.2020.100318","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Authors. Published by Elsevier Inc. on behalf of the International Society for Sexual Medicine.","name":"copyright","label":"Copyright"}]}}