{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T02:23:45Z","timestamp":1793759025150,"version":"4.6.1"},"reference-count":18,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","europeanurology.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["European Urology"],"published-print":{"date-parts":[[2019,1]]},"DOI":"10.1016\/j.eururo.2018.07.036","type":"journal-article","created":{"date-parts":[[2018,8,20]],"date-time":"2018-08-20T09:25:01Z","timestamp":1534757101000},"page":"169-175","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":57,"title":["Robot-assisted AMS-800 Artificial Urinary Sphincter Bladder Neck Implantation in Female Patients with Stress Urinary Incontinence"],"prefix":"10.1016","volume":"75","author":[{"given":"Benoit","family":"Peyronnet","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gr\u00e9goire","family":"Capon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olivier","family":"Belas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Manunta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cl\u00e9ment","family":"Allenet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juliette","family":"Hascoet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jehanne","family":"Calves","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michel","family":"Belas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Callerot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gr\u00e9goire","family":"Robert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aur\u00e9lien","family":"Descazeaud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georges","family":"Fournier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.eururo.2018.07.036_bib0095","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.1016\/j.eururo.2012.09.023","article-title":"EAU guidelines on surgical treatment of urinary incontinence","volume":"62","author":"Lucas","year":"2012","journal-title":"Eur Urol"},{"key":"10.1016\/j.eururo.2018.07.036_bib0100","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1002\/nau.20844","article-title":"Committee of the International Consultation on Incontinence. Surgical treatment of stress incontinence in men","volume":"29","author":"Herschorn","year":"2010","journal-title":"Neurourol Urodyn"},{"key":"10.1016\/j.eururo.2018.07.036_bib0105","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.urology.2012.04.065","article-title":"International variation in artificial urinary sphincter use","volume":"80","author":"Matsushita","year":"2012","journal-title":"Urology"},{"key":"10.1016\/j.eururo.2018.07.036_bib0110","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1007\/s11934-014-0427-0","article-title":"Management of recurrent stress incontinence following a sling","volume":"15","author":"Nadeau","year":"2014","journal-title":"Curr Urol Rep"},{"key":"10.1016\/j.eururo.2018.07.036_bib0115","doi-asserted-by":"crossref","first-page":"1618","DOI":"10.1111\/j.1464-410X.2010.09610.x","article-title":"Artificial urinary sphincter (AMS 800) implantation for women with intrinsic sphincter deficiency: a technique for insiders?","volume":"107","author":"Chartier-Kastler","year":"2011","journal-title":"BJU Int"},{"key":"10.1016\/j.eururo.2018.07.036_bib0120","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1111\/j.1464-410X.2010.09206.x","article-title":"Laparoscopic artificial urinary sphincter implantation for female genuine stress urinary incontinence: technique and 4-year experience in 25 patients","volume":"106","author":"Mandron","year":"2010","journal-title":"BJU Int"},{"key":"10.1016\/j.eururo.2018.07.036_bib0125","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/j.eururo.2009.03.045","article-title":"Laparoscopic approach for artificial urinary sphincter implantation in women with intrinsic sphincter deficiency incontinence: a single-centre preliminary experience","volume":"57","author":"Roupr\u00eat","year":"2010","journal-title":"Eur Urol"},{"key":"10.1016\/j.eururo.2018.07.036_bib0130","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1016\/j.urology.2014.07.013","article-title":"Robotic-assisted laparoscopic implantation of artificial urinary sphincter in women with intrinsic sphincter deficiency incontinence: initial results","volume":"84","author":"Fournier","year":"2014","journal-title":"Urology"},{"key":"10.1016\/j.eururo.2018.07.036_bib0135","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1016\/S0022-5347(05)66459-2","article-title":"The use of an artificial urinary sphincter in women with type III incontinence and a negative Marshall test","volume":"165","author":"Costa","year":"2001","journal-title":"J Urol"},{"key":"10.1016\/j.eururo.2018.07.036_bib0140","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1007\/s00192-015-2858-7","article-title":"Artificial urinary sphincter implantation in women with stress urinary incontinence: preliminary comparison of robot-assisted and open approaches","volume":"27","author":"Peyronnet","year":"2016","journal-title":"Int Urogynecol J"},{"key":"10.1016\/j.eururo.2018.07.036_bib0145","doi-asserted-by":"crossref","first-page":"2550","DOI":"10.1007\/s00268-016-3543-9","article-title":"30 Years of robotic surgery","volume":"40","author":"Leal Ghezzi","year":"2016","journal-title":"World J Surg"},{"key":"10.1016\/j.eururo.2018.07.036_bib0150","doi-asserted-by":"crossref","first-page":"937","DOI":"10.1016\/j.eururo.2014.12.041","article-title":"Robot-assisted laparoscopic approach for artificial urinary sphincter implantation in 11 women with urinary stress incontinence: surgical technique and initial experience","volume":"67","author":"Biardeau","year":"2015","journal-title":"Eur Urol"},{"key":"10.1016\/j.eururo.2018.07.036_bib0155","doi-asserted-by":"crossref","first-page":"2622","DOI":"10.1016\/j.juro.2009.01.113","article-title":"Temporal trends in adoption of and indications for the artificial urinary sphincter","volume":"181","author":"Lee","year":"2009","journal-title":"J Urol"},{"key":"10.1016\/j.eururo.2018.07.036_bib0160","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.purol.2015.03.006","article-title":"Intrinsic sphincter deficiency and female urinary incontinence","volume":"25","author":"Cour","year":"2015","journal-title":"Prog Urol"},{"key":"10.1016\/j.eururo.2018.07.036_bib0165","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1016\/j.juro.2017.06.061","article-title":"Surgical treatment of female stress urinary incontinence: AUA\/SUFU guideline","volume":"198","author":"Kobashi","year":"2017","journal-title":"J Urol"},{"key":"10.1016\/j.eururo.2018.07.036_bib0170","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1007\/s00345-015-1599-z","article-title":"Considerations in the modern management of stress urinary incontinence resulting from intrinsic sphincter deficiency","volume":"33","author":"Hillary","year":"2015","journal-title":"World J Urol"},{"key":"10.1016\/j.eururo.2018.07.036_bib0175","doi-asserted-by":"crossref","first-page":"E396","DOI":"10.5489\/cuaj.4493","article-title":"Montreal electronic artificial urinary sphincters: our futuristic alternatives to the AMS800\u2122","volume":"11","author":"Biardeau","year":"2017","journal-title":"Can Urol Assoc J"},{"key":"10.1016\/j.eururo.2018.07.036_bib0180","doi-asserted-by":"crossref","first-page":"E337","DOI":"10.1111\/j.1464-410X.2012.11728.x","article-title":"Experimental evaluation of an electromechanical artificial urinary sphincter in an animal model","volume":"112","author":"Valerio","year":"2013","journal-title":"BJU Int"}],"container-title":["European Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S030228381830558X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S030228381830558X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,8,30]],"date-time":"2019-08-30T10:09:08Z","timestamp":1567159748000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S030228381830558X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["S030228381830558X"],"URL":"https:\/\/doi.org\/10.1016\/j.eururo.2018.07.036","relation":{},"ISSN":["0302-2838"],"issn-type":[{"value":"0302-2838","type":"print"}],"subject":[],"published":{"date-parts":[[2019,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Robot-assisted AMS-800 Artificial Urinary Sphincter Bladder Neck Implantation in Female Patients with Stress Urinary Incontinence","name":"articletitle","label":"Article Title"},{"value":"European Urology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.eururo.2018.07.036","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 European Association of Urology. Published by Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}