{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T21:09:37Z","timestamp":1792012177666,"version":"4.4.0"},"reference-count":46,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["12372301"],"award-info":[{"award-number":["12372301"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82000878"],"award-info":[{"award-number":["82000878"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012226","name":"Fundamental Research Funds for the Central Universities","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100012226","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012166","name":"National Key Research and Development Program of China","doi-asserted-by":"publisher","award":["2023YFC3604101"],"award-info":[{"award-number":["2023YFC3604101"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Experimental Eye Research"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1016\/j.exer.2026.110847","type":"journal-article","created":{"date-parts":[[2026,1,3]],"date-time":"2026-01-03T16:18:48Z","timestamp":1767457128000},"page":"110847","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Lens shape change is influenced by zonular anchorage and stretching mechanism"],"prefix":"10.1016","volume":"264","author":[{"given":"Yutian","family":"Pu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunjing","family":"Tao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barbara K.","family":"Pierscionek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kehao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.exer.2026.110847_bib1","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.cmpb.2006.08.005","article-title":"Sensitivity study of human crystalline lens accommodation","volume":"85","author":"Abolmaali","year":"2007","journal-title":"Comput. Methods Progr. Biomed."},{"key":"10.1016\/j.exer.2026.110847_bib2","doi-asserted-by":"crossref","DOI":"10.3390\/ijms23094710","article-title":"Mechanical load and Piezo1 channel regulated myosin II activity in mouse lenses","volume":"23","author":"Allen","year":"2022","journal-title":"Int. J. Mol. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib3","doi-asserted-by":"crossref","DOI":"10.1016\/j.preteyeres.2020.100902","article-title":"Zinn's zonule","volume":"82","author":"Bassnett","year":"2021","journal-title":"Prog. Retin. Eye Res."},{"key":"10.1016\/j.exer.2026.110847_bib4","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1021\/acsmacrolett.9b00258","article-title":"Strain-Stiffening of agarose gels","volume":"8","author":"Bertula","year":"2019","journal-title":"ACS Macro Lett."},{"key":"10.1016\/j.exer.2026.110847_bib5","doi-asserted-by":"crossref","first-page":"5093","DOI":"10.1167\/iovs.16-20143","article-title":"In vivo brillouin analysis of the aging crystalline lens","volume":"57","author":"Besner","year":"2016","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib6","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1111\/opo.12876","article-title":"A validated finite element model to reproduce Helmholtz's theory of accommodation: a powerful tool to investigate presbyopia","volume":"41","author":"Cabeza-Gil","year":"2021","journal-title":"Ophthalmic Physiol. Opt."},{"key":"10.1016\/j.exer.2026.110847_bib7","doi-asserted-by":"crossref","DOI":"10.1016\/j.bbadis.2024.167265","article-title":"Characterization of mechanical stress in the occurrence of cortical opacification in age-related cataracts using three-dimensional finite element model of the human lens and RNA-seq","volume":"1870","author":"Chen","year":"2024","journal-title":"Biochim. Biophys. Acta Mol. Basis Dis."},{"key":"10.1016\/j.exer.2026.110847_bib8","doi-asserted-by":"crossref","DOI":"10.3389\/fopht.2024.1508779","article-title":"Influence of zonular tension on molecular transport in the porcine ocular lens","volume":"4","author":"Crews","year":"2024","journal-title":"Front. Ophthalmol."},{"key":"10.1016\/j.exer.2026.110847_bib9","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1080\/10255842.2016.1228907","article-title":"Accommodation of the human lens capsule using a finite element model based on nonlinear regionally anisotropic biomembranes","volume":"20","author":"David","year":"2017","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"10.1016\/j.exer.2026.110847_bib10","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1167\/iovs.64.11.31","article-title":"Estimation of crystalline lens material properties from patient accommodation data and finite element models","volume":"64","author":"de la Hoz","year":"2023","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib11","doi-asserted-by":"crossref","first-page":"2876","DOI":"10.1364\/BOE.512193","article-title":"Dynamic refraction and anterior segment OCT biometry during accommodation","volume":"15","author":"Durkee","year":"2024","journal-title":"Biomed. Opt. Express"},{"key":"10.1016\/j.exer.2026.110847_bib12","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/0014-4835(79)90091-5","article-title":"Anterior zonular shifts with age","volume":"28","author":"Farnsworth","year":"1979","journal-title":"Exp. Eye Res."},{"key":"10.1016\/j.exer.2026.110847_bib13","doi-asserted-by":"crossref","first-page":"4004","DOI":"10.1038\/s41598-024-54674-w","article-title":"The potential influence of the ligament of Wieger on the crystalline lens shape","volume":"14","author":"Ghaderi","year":"2024","journal-title":"Sci. Rep."},{"key":"10.1016\/j.exer.2026.110847_bib14","first-page":"1","article-title":"Ueber die Accommodation des Auges","volume":"2","author":"Helmholtz","year":"1855","journal-title":"Arch. f\u00fcr Opthalmologie"},{"key":"10.1016\/j.exer.2026.110847_bib15","doi-asserted-by":"crossref","first-page":"1179","DOI":"10.1097\/OPX.0b013e31818e8d57","article-title":"Equivalent refractive index of the human lens upon accommodative response","volume":"85","author":"Hermans","year":"2008","journal-title":"Optom. Vis. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib16","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1016\/j.visres.2005.11.012","article-title":"Age related changes in accommodative dynamics in humans","volume":"46","author":"Kasthurirangan","year":"2006","journal-title":"Vis. Res."},{"key":"10.1016\/j.exer.2026.110847_bib17","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1038\/s43856-024-00578-9","article-title":"Optical coherence tomography quantifies gradient refractive index and mechanical stiffness gradient across the human lens","volume":"4","author":"Kling","year":"2024","journal-title":"Commun. Med."},{"key":"10.1016\/j.exer.2026.110847_bib18","doi-asserted-by":"crossref","DOI":"10.1016\/j.exer.2025.110332","article-title":"Dynamic in vivo mapping of the gradient refractive index and strain distribution of the human lens under accommodative stress","volume":"255","author":"Kling","year":"2025","journal-title":"Exp. Eye Res."},{"key":"10.1016\/j.exer.2026.110847_bib19","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1007\/s10237-021-01417-9","article-title":"The action of ciliary muscle contraction on accommodation of the lens explored with a 3D model","volume":"20","author":"Knaus","year":"2021","journal-title":"Biomech. Model. Mechanobiol."},{"key":"10.1016\/j.exer.2026.110847_bib20","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1167\/iovs.02-0256","article-title":"Polymer refilling of presbyopic human lenses in vitro restores the ability to undergo accommodative changes","volume":"44","author":"Koopmans","year":"2003","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib21","doi-asserted-by":"crossref","first-page":"3920","DOI":"10.1167\/iovs.19-26893","article-title":"Lens stretching modulates lens epithelial cell proliferation via YAP regulation","volume":"60","author":"Kumar","year":"2019","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib22","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/j.compmedimag.2006.09.008","article-title":"A study for accommodating the human crystalline lens by finite element simulation","volume":"30","author":"Liu","year":"2006","journal-title":"Comput. Med. Imag. Graph."},{"key":"10.1016\/j.exer.2026.110847_bib23","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1007\/s10237-007-0081-2","article-title":"Aspects of eye accommodation evaluated by finite elements","volume":"7","author":"Ljubimova","year":"2008","journal-title":"Biomech. Model. Mechanobiol."},{"key":"10.1016\/j.exer.2026.110847_bib24","doi-asserted-by":"crossref","first-page":"3260","DOI":"10.1167\/iovs.06-1376","article-title":"Optomechanical response of human and monkey lenses in a lens stretcher","volume":"48","author":"Manns","year":"2007","journal-title":"Investig. Opthalmol. Vis. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib25","doi-asserted-by":"crossref","first-page":"4239","DOI":"10.1167\/iovs.15-17050","article-title":"Measurement of crystalline lens volume during accommodation in a lens stretcher","volume":"56","author":"Marussich","year":"2015","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib26","doi-asserted-by":"crossref","first-page":"30532","DOI":"10.18632\/oncotarget.5762","article-title":"The eye lens: age-related trends and individual variations in refractive index and shape parameters","volume":"6","author":"Pierscionek","year":"2015","journal-title":"Oncotarget"},{"key":"10.1016\/j.exer.2026.110847_bib27","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1111\/cxo.12263","article-title":"Stretch-dependent changes in surface profiles of the human crystalline lens during accommodation: a finite element study","volume":"98","author":"Pour","year":"2015","journal-title":"Clin. Exp. Optom."},{"key":"10.1016\/j.exer.2026.110847_bib28","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1167\/iovs.66.1.16","article-title":"Age-related changes in lens elasticity contribute more to accommodative decline than shape change","volume":"66","author":"Pu","year":"2025","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib29","doi-asserted-by":"crossref","DOI":"10.1016\/j.cmpb.2023.107815","article-title":"The major influence of anterior and equatorial zonular fibres on the far-to-near accommodation revealed by a 3D pre-stressed model of the anterior eye","volume":"242","author":"Pu","year":"2023","journal-title":"Comput. Methods Progr. Biomed."},{"key":"10.1016\/j.exer.2026.110847_bib30","first-page":"245","article-title":"Critical values for Spearman's rank order correlation","volume":"14","author":"Ramsey","year":"1989","journal-title":"J. Educ. Stat."},{"key":"10.1016\/j.exer.2026.110847_bib31","first-page":"133","article-title":"Scanning electron microscopic studies of the zonular apparatus in human and monkey eyes","volume":"18","author":"Rohen","year":"1979","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib32","first-page":"36","article-title":"Zonular function: a new hypothesis with clinical implications","volume":"26","author":"Schachar","year":"1994","journal-title":"Ann. Ophthalmol."},{"key":"10.1016\/j.exer.2026.110847_bib33","doi-asserted-by":"crossref","DOI":"10.1016\/j.exer.2023.109709","article-title":"Finite element analysis of zonular forces","volume":"237","author":"Schachar","year":"2023","journal-title":"Exp. Eye Res."},{"key":"10.1016\/j.exer.2026.110847_bib34","first-page":"1162","article-title":"Age-related changes in human ciliary muscle and lens: a magnetic resonance imaging study","volume":"40","author":"Strenk","year":"1999","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"10.1016\/j.exer.2026.110847_bib35","series-title":"Duane's Opthalmology","author":"Tasman","year":"2000"},{"key":"10.1016\/j.exer.2026.110847_bib36","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1016\/0042-6989(91)90061-9","article-title":"Elasticity of tissues involved in accommodation","volume":"31","author":"van Alphen","year":"1991","journal-title":"Vis. Res."},{"key":"10.1016\/j.exer.2026.110847_bib37","article-title":"Influence of lens thickness on the accommodative range in healthy eyes","volume":"18","author":"Vermeulen","year":"2025","journal-title":"J. Opt."},{"key":"10.1016\/j.exer.2026.110847_bib38","doi-asserted-by":"crossref","first-page":"B116","DOI":"10.1364\/JOSAA.36.00B116","article-title":"Contributions of shape and stiffness to accommodative loss in the ageing human lens: a finite element model assessment","volume":"36","author":"Wang","year":"2019","journal-title":"J. Opt. Soc. Am. A"},{"key":"10.1016\/j.exer.2026.110847_bib39","doi-asserted-by":"crossref","DOI":"10.1016\/j.preteyeres.2018.11.004","article-title":"Biomechanics of the human lens and accommodative system: functional relevance to physiological states","author":"Wang","year":"2019","journal-title":"Prog. Retin. Eye Res."},{"key":"10.1016\/j.exer.2026.110847_bib40","article-title":"Gradient moduli lens models: how material properties and application of forces can affect deformation and distributions of stress","volume":"6","author":"Wang","year":"2016","journal-title":"Sci. Rep."},{"key":"10.1016\/j.exer.2026.110847_bib41","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1109\/TBME.2019.2927390","article-title":"A modeling approach for investigating opto-mechanical relationships in the human eye lens","volume":"67","author":"Wang","year":"2020","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.exer.2026.110847_bib42","article-title":"The importance of parameter choice in modelling dynamics of the eye lens article","volume":"7","author":"Wang","year":"2017","journal-title":"Sci. Rep."},{"key":"10.1016\/j.exer.2026.110847_bib43","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmps.2023.105360","article-title":"Strain stiffening retards growth instability in residually stressed biological tissues","volume":"178","author":"Wang","year":"2023","journal-title":"J. Mech. Phys. Solid."},{"key":"10.1016\/j.exer.2026.110847_bib44","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.exer.2012.01.011","article-title":"Shear modulus data for the human lens determined from a spinning lens test","volume":"97","author":"Wilde","year":"2012","journal-title":"Exp. Eye Res."},{"key":"10.1016\/j.exer.2026.110847_bib45","article-title":"Effects of accommodation on geometrical parameters of human lens: a systematic review and meta-analysis","volume":"10","author":"Zhang","year":"2024","journal-title":"Heliyon"},{"key":"10.1016\/j.exer.2026.110847_bib46","doi-asserted-by":"crossref","first-page":"3083","DOI":"10.1007\/s00417-023-06045-w","article-title":"The evolution of mechanism of accommodation and a novel hypothesis","volume":"261","author":"Zhang","year":"2023","journal-title":"Graefe\u2019s Arch. Clin. Exp. Ophthalmol."}],"container-title":["Experimental Eye Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0014483526000035?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0014483526000035?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T08:40:39Z","timestamp":1781685639000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0014483526000035"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":46,"alternative-id":["S0014483526000035"],"URL":"https:\/\/doi.org\/10.1016\/j.exer.2026.110847","relation":{},"ISSN":["0014-4835"],"issn-type":[{"value":"0014-4835","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Lens shape change is influenced by zonular anchorage and stretching mechanism","name":"articletitle","label":"Article Title"},{"value":"Experimental Eye Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.exer.2026.110847","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"110847"}}