{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T14:26:08Z","timestamp":1768746368022,"version":"3.49.0"},"reference-count":36,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2009,12,1]],"date-time":"2009-12-01T00:00:00Z","timestamp":1259625600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Foot and Ankle Surgery"],"published-print":{"date-parts":[[2009,12]]},"DOI":"10.1016\/j.fas.2009.02.008","type":"journal-article","created":{"date-parts":[[2009,4,17]],"date-time":"2009-04-17T08:51:31Z","timestamp":1239958291000},"page":"192-197","source":"Crossref","is-referenced-by-count":25,"title":["A retrospective follow-up of ankle fracture patients treated with a biodegradable plate and screws"],"prefix":"10.1016","volume":"15","author":[{"given":"Arvo","family":"Kukk","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janne T.","family":"Nurmi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.fas.2009.02.008_bib1","unstructured":"PearlDiver Inc., database services <www.pearldiverinc.com>."},{"issue":"suppl. 4","key":"10.1016\/j.fas.2009.02.008_bib2","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/S0020-1383(00)80020-0","article-title":"Bioresorbable polymers in trauma and bone surgery","volume":"31","author":"Gogolewski","year":"2000","journal-title":"Injury"},{"key":"10.1016\/j.fas.2009.02.008_bib3","doi-asserted-by":"crossref","first-page":"2607","DOI":"10.1016\/S0142-9612(00)00128-9","article-title":"Bioabsorbable fixation in orthopaedic surgery and traumatology","volume":"21","author":"Rokkanen","year":"2000","journal-title":"Biomaterials"},{"key":"10.1016\/j.fas.2009.02.008_bib4","doi-asserted-by":"crossref","first-page":"166","DOI":"10.3109\/17453679408995427","article-title":"Biodegradable fixation of ankle fractures A roentgen stereophotogrammetric study of 32 cases","volume":"65","author":"Ahl","year":"1994","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.fas.2009.02.008_bib5","doi-asserted-by":"crossref","first-page":"319","DOI":"10.2106\/00004623-199403000-00001","article-title":"Fixation with bioabsorbable screws for the treatment of fractures of the ankle","volume":"76","author":"Bucholz","year":"1994","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.fas.2009.02.008_bib6","first-page":"109","article-title":"Resorbable rods and screws of polyglycolide in stabilizing malleolar fractures. A clinical study of 600 patients","volume":"95","author":"B\u00f6stman","year":"1992","journal-title":"Unfallchirurg"},{"key":"10.1016\/j.fas.2009.02.008_bib7","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1177\/107110079301400108","article-title":"Distal tibiofibular synostosis after malleolar fractures treated using absorbable implants","volume":"14","author":"B\u00f6stman","year":"1993","journal-title":"Foot Ankle"},{"key":"10.1016\/j.fas.2009.02.008_bib8","doi-asserted-by":"crossref","first-page":"26","DOI":"10.2106\/00004623-200201000-00005","article-title":"Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation","volume":"84","author":"Hovis","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.fas.2009.02.008_bib9","first-page":"263","article-title":"Biodegradable self-reinforced polyglycolide screws and rods in the fixation of displaced malleolar fractures in the elderly. A comparison with metallic implants","volume":"85","author":"Kankare","year":"1996","journal-title":"Ann Chir Gynaecol"},{"key":"10.1016\/j.fas.2009.02.008_bib10","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1177\/107110070202300811","article-title":"Ruptured tibio-fibular syndesmosis: comparison study of metallic to bioabsorbable fixation","volume":"23","author":"Sinisaari","year":"2002","journal-title":"Foot Ankle Int"},{"key":"10.1016\/j.fas.2009.02.008_bib11","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1177\/107110070102200411","article-title":"Bioabsorbable versus stainless steel screw fixation of the syndesmosis in pronation-lateral rotation ankle fractures: a prospective randomized trial","volume":"22","author":"Thordarson","year":"2001","journal-title":"Foot Ankle Int"},{"key":"10.1016\/j.fas.2009.02.008_bib12","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1097\/00001665-200407000-00031","article-title":"Successful use of biosorb osteofixation devices in 165 cranial and maxillofacial cases: a multicenter report","volume":"15","author":"Ashammakhi","year":"2004","journal-title":"J Craniofac Surg"},{"key":"10.1016\/j.fas.2009.02.008_bib13","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1016\/j.tripleo.2004.02.069","article-title":"A randomized controlled trial of resorbable versus titanium fixation for orthognathic surgery","volume":"98","author":"Cheung","year":"2004","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.fas.2009.02.008_bib14","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1016\/j.ijom.2007.09.169","article-title":"Stability and morbidity of Le Fort I osteotomy with bioresorbable fixation: a randomized controlled trial","volume":"37","author":"Cheung","year":"2008","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.fas.2009.02.008_bib15","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.joms.2004.11.011","article-title":"Use of resorbable plates and screws in pediatric facial fractures","volume":"63","author":"Eppley","year":"2005","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.fas.2009.02.008_bib16","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1097\/01.PRS.0000132856.69391.43","article-title":"Resorbable PLLA-PGA plate and screw fixation in pediatric craniofacial surgery: clinical experience in 1883 patients","volume":"114","author":"Eppley","year":"2004","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.fas.2009.02.008_bib17","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.joms.2005.10.055","article-title":"Resorbable plates for the fixation of mandibular fractures: a prospective study","volume":"65","author":"Laughlin","year":"2007","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.fas.2009.02.008_bib18","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1055\/s-2008-1064301","article-title":"Update on bioresorbable plates in maxillofacial surgery","volume":"15","author":"Suuronen","year":"1999","journal-title":"Facial Plast Surg"},{"key":"10.1016\/j.fas.2009.02.008_bib19","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.tripleo.2004.11.013","article-title":"Biodegradable fixation of mandibular fractures in children: stability and early results","volume":"100","author":"Yerit","year":"2005","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.fas.2009.02.008_bib20","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1097\/00003086-199608000-00029","article-title":"Metallic or absorbable fracture fixation devices. A cost minimization analysis.","volume":"329","author":"B\u00f6stman","year":"1996","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.fas.2009.02.008_bib21","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1007\/BF00393710","article-title":"Comparison of costs in ankle fractures treated with absorbable or metallic fixation devices","volume":"116","author":"Juutilainen","year":"1997","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.fas.2009.02.008_bib22","first-page":"413","article-title":"Surgical treatment of ankle joint fractures with biodegradable screws and plates of poly-l-lactide","volume":"67","author":"Eitenm\u00fcller","year":"1996","journal-title":"Chirurg"},{"key":"10.1016\/j.fas.2009.02.008_bib23","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.jhsb.2005.09.015","article-title":"Dorsal plating of unstable distal radius fractures using a bio-absorbable plating system and bone substitute.","volume":"31","author":"Gangopadhyay","year":"2006","journal-title":"J Hand Surg [Br]"},{"key":"10.1016\/j.fas.2009.02.008_bib24","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1097\/01.TA.0000090037.72142.33","article-title":"Absorbable plates for rib fracture repair: preliminary experience","volume":"55","author":"Mayberry","year":"2003","journal-title":"J Trauma"},{"key":"10.1016\/j.fas.2009.02.008_bib25","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1016\/j.jhsa.2004.01.013","article-title":"Self-reinforced bioabsorbable miniplates for skeletal fixation in complex hand injury: three case reports","volume":"29","author":"Waris","year":"2004","journal-title":"J Hand Surg [Am]"},{"issue":"Suppl","key":"10.1016\/j.fas.2009.02.008_bib26","first-page":"110","article-title":"Supination-outward rotation injuries of the ankle. A clinical and, roentgenological study with special reference to the operative treatment.","author":"Cedell","year":"1967","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.fas.2009.02.008_bib27","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1007\/BF00435553","article-title":"A scoring scale for symptom evaluation after ankle fracture","volume":"103","author":"Olerud","year":"1984","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.fas.2009.02.008_bib28","doi-asserted-by":"crossref","first-page":"1485","DOI":"10.1002\/jor.20684","article-title":"Biomechanical in vitro evaluation of the effect of cyclic loading on the postoperative fixation stability and degradation of a biodegradable ankle plate","volume":"26","author":"V\u00e4\u00e4n\u00e4nen","year":"2008","journal-title":"J Orthop Res"},{"key":"10.1016\/j.fas.2009.02.008_bib29","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1007\/s10856-007-3082-x","article-title":"Degradative and mechanical properties of a novel resorbable plating system during a 3-year follow-up in vivo and in vitro","volume":"19","author":"Nieminen","year":"2008","journal-title":"J Mater Sci Mater Med"},{"key":"10.1016\/j.fas.2009.02.008_bib30","doi-asserted-by":"crossref","first-page":"2635","DOI":"10.1016\/S0142-9612(00)00132-0","article-title":"Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices","volume":"21","author":"An","year":"2000","journal-title":"Biomaterials"},{"key":"10.1016\/j.fas.2009.02.008_bib31","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1097\/SCS.0b013e31816aab24","article-title":"Biodegradation of Inion fast-absorbing biodegradable plates and screws","volume":"19","author":"Losken","year":"2008","journal-title":"J Craniofac Surg"},{"key":"10.1016\/j.fas.2009.02.008_bib32","doi-asserted-by":"crossref","first-page":"2335","DOI":"10.1016\/S0142-9612(00)00101-0","article-title":"Synthetic biodegradable polymers as orthopaedic devices","volume":"21","author":"Middleton","year":"2000","journal-title":"Biomaterials"},{"key":"10.1016\/j.fas.2009.02.008_bib33","doi-asserted-by":"crossref","first-page":"2615","DOI":"10.1016\/S0142-9612(00)00129-0","article-title":"Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review","volume":"21","author":"B\u00f6stman","year":"2000","journal-title":"Biomaterials"},{"key":"10.1016\/j.fas.2009.02.008_bib34","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1023\/B:ABME.0000007802.59936.fc","article-title":"Bioabsorbable implants: review of clinical experience in orthopedic surgery","volume":"32","author":"Ambrose","year":"2004","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.fas.2009.02.008_bib35","doi-asserted-by":"crossref","first-page":"1906","DOI":"10.2106\/JBJS.F.01536","article-title":"Removal of painful orthopaedic implants after fracture union","volume":"89","author":"Minkowitz","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.fas.2009.02.008_bib36","doi-asserted-by":"crossref","first-page":"205","DOI":"10.2106\/00004623-200302000-00004","article-title":"Use of a cast compared with a functional ankle brace after operative treatment of an ankle fracture. A prospective, randomized study.","volume":"85","author":"Lehtonen","year":"2003","journal-title":"J Bone Joint Surg Am"}],"container-title":["Foot and Ankle Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1268773109000307?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1268773109000307?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,5,19]],"date-time":"2019-05-19T14:15:53Z","timestamp":1558275353000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1268773109000307"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,12]]},"references-count":36,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["S1268773109000307"],"URL":"https:\/\/doi.org\/10.1016\/j.fas.2009.02.008","relation":{},"ISSN":["1268-7731"],"issn-type":[{"value":"1268-7731","type":"print"}],"subject":[],"published":{"date-parts":[[2009,12]]}}}